Perfect Aire PAU13 Bruksanvisning

Läs gratis den bruksanvisning för Perfect Aire PAU13 (15 sidor) i kategorin Luftfuktare. Guiden har ansetts hjälpsam av 22 personer och har ett genomsnittsbetyg på 4.5 stjärnor baserat på 11.5 recensioner. Har du en fråga om Perfect Aire PAU13 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/15
ULTRASONIC COOL MIST
HUMIDIFIER
PAU13
Before using your ultrasonic humidifer, please read this
manual carefully and keep it for future reference, along
with your receipt.
USER MANUAL/
MANUEL DE L’UTILISATEUR
FOR MODEL/
POUR MODÈLE:
HUMIDIFICATEUR
ULTRASONIQUE À VAPEUR FRAÌCHE
R
E
M
P
L
A
C
E
M
E
N
T
C
O
M
P
L
E
T
G
A
R
A
N
T
I
E
1 AN
Avant d’utiliser votre humidificateur ultrasonique, veuillez
lire attentivement ce manual et le conserver pour
r
éférence ultérieure, avec votre reçu.
1
Safety Guidelines..........................................................3
Technical Data..............................................................3
Features........................................................................3
Parts Diagram ............................................................. 4
Humidifier Placement .................................................. 4
Refilling the Water Tank .............................................. 4
Operating Instructions ................................................... 5
Weekly Maintenance ................................................... 5
Storage Instructions .................................................... 5
Warranty ...................................................................... 7
Troubleshooting .......................................................... 6
2
1. Always have water in water tank (water bottle) when operating unit.
2. We recommend using only filtered or distilled water. Using tap water with a high mineral content (hard water) will result in a white dust and the need for more
frequent cleanings. Hard water can damage the nebulizer and may eventually cause it to fail.
3. Be sure the cap is firmly fastened onto the tank.
4. Position the unit so the mist control output nozzle is aimed away from children, walls and furniture in the room
(min. 36 in/91 cm clearance) to avoid condensation and property damage.
5. When removing the tank, grasp it firmly with both hands, before using one hand to support the bottom.
6. DO NOT use this unit if the tank is cracked.
7. DO NOT place the humidifier near heat sources such as a stove, oven, or direct sunlight. Keep the cord away from hot surfaces and areas where it can be stepped
on or tripped over.
8. Use only a dedicated, grounded 115-120V AC outlet, making sure the unit is plugged in firmly and completely. Plug and unplug the unit with dry hands only.
9. Turn off and unplug the unit when moving or cleaning it, or when it's not in use.
10. T
o avoid the risk of fire, shock, or personal injury, do not use an extension cord or power strip.
Warning: Never operate the unit with a damaged cord or plug.
11. DO NOT place on the floor or carpet. Always place the unit on a flat, level, waterproof surface at least 24 in. (61cm) off the floor AWAY from direct sunlight,
computers or other sensitive electronics.
12.
DO NOT place the humidifier on wood furniture or other surfaces that can be damaged by water.
13. DO NOT place the unit on towels or soft surfaces. This will block the air vent and cause overheating.
14. DO NOT add medicine, essential oils, or cleaning products of any type into the mist control nozzle, base or water tank (See the “Weekly Maintenance Cleaning &
Care” section for proper cleaning instructions). NEVER cover or block any openings on the unit. NEVER drop or insert any objects into any openings.
15. The unit should not be left unattended in closed rooms as air could become too humid and leave condensation on the walls or furniture. Always leave
a door
partially open.
16. DANGER: NEVER immerse the humidifier base (motor unit) in water or other liquids as electrical shock may occur.
17. DO NOT use the unit outdoors.
18. Turn the humidifier OFF if the relative humidity exceeds 60% or if you notice condensation on the windows. For a proper humidity reading, use a hygrometer which
is available in many retail stores.
19. The nebulizer (ultrasonic transducer) is highly sensitive. Keep this important part clean and treat it gently. Clean only according to the instructions on page 7.
WARNING:
Do not touch the nebulizer while the unit is operating, as possible burns could result.
Do not touch the nebulizer with fingers. Any residue on the metal will reduce mist output.
20. The unit contains no user serviceable parts. To reduce the risk of electrical shock, do not attempt to open the base of the humidifier.
SAFETY GUIDELINES
When using electrical appliances, basic safety precautions should always be followed. Failure to follow
these safety precautions may result in personal injury, property damage, fire or shock.
CONTENTS
DANGER! T
o reduce the risk of electrical shock, this product has a polarized plug (one blade is wider than the other). As a
safety feature this plug will fit into the outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician. DO NOT attempt to bypass this safety feature. Improper use of electric cords and
plugs can cause a fire or electric shock hazard. NEVER pull on the cord to remove the plug from the outlet. Grip the plug and
pull directly from the outlet. Check the power cord and plug for damage. If the cord or plug are damaged, contact Customer
Service before using the humidifier.
2
DATA
FOR HOUSEHOLD USE ONLY
All data was tested by the factory and are for reference only. This unit
is designed for home use only.
ULTRASONIC TECHNOLOGY
An ultrasonic transducer atomizes water droplets into ultra-fine particles which are dispersed into the air as a refreshing cool mist.
AUTO SHUT OFF PROTECTION / WATERLESS INDICATOR
When the water tank is empty, the motor will shut off automatically and the Power Indicator Light will turn red.
OVERLOAD PROTECTION
The unit will automatically shut off if a circuit is overloaded.
NIGHT LIGHT
Creates a soft illumination. To turn on the night light, push the night light button. Repeat the process to turn it off.
FEATURES
Model:
PAU13
Voltage: 115-120V~/60Hz Watts: 35W Max.
Run Time: 36 hours Water Tank Capacity: 1.3
gal (4.
9
L)
3
PARTS DIAGRAM
0
H
B
F
C
I
M
N
A.
Mist Nozzle
B.
Water Tank Handle
C.
Water Tank
D.
Tank Cap (located underneath the tank)
E.
Power/Humidit
y
Control Knob
F.
Power Light/Water Refill Indicator
G.
Ultrasonic Transducer
(Nebulizer - circle inside the black ring at
the bottom)
H.
Base
I.
Fan Outlet
J.
Power Cord
K.
Water Level Sensor
L.
Brush Holder for Nebulizer (brush included)
M.
Night Light
N.
Night Light On/Off Switch
O.
Base Handle
HUMIDIFIER PLACEMENT
3. Always place the humidifier on a firm, flat, level,
waterproof s
urface, at least 24 in (61 cm) off the floor.
4. Do not place the unit near the stove or other heat sources. Do not
place the unit in direct sunlight.
1. Place the unit at least 6 ft (1.83 m) away from wood furniture, TVs,
stereos and other electronic appliances.
>
1.
8
3 m
2. Do not place unit near curtains, paintings/portraits, bedding or wood
furniture.
REFILLING THE WATER TANK
Unplug the unit before refilling the tank.
Do not set the unit on a soft surface such as a towel or carpet. NOTE: Do not fill the base of the unit.
Only add water to the tank.
1. Hold the tank handle and lift the water tank from the base. If the
unit was in use you may want a towel readily available for any water
dripping.
2. Carefully turn the water tank upside down; unscrew
down; unscrew the tank cap by turning it counter-
clockwise and set aside.
3

Produktspecifikationer

Varumärke: Perfect Aire
Kategori: Luftfuktare
Modell: PAU13

Behöver du hjälp?

Om du behöver hjälp med Perfect Aire PAU13 ställ en fråga nedan och andra användare kommer att svara dig