Schneider CCTFR6100Z3 Bruksanvisning
Läs gratis den bruksanvisning för Schneider CCTFR6100Z3 (6 sidor) i kategorin Termostat. Guiden har ansetts hjälpsam av 19 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 10 recensioner. Har du en fråga om Schneider CCTFR6100Z3 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/6

!
$
%
CCTFR6100Z3
en cs dabg en Wiser Radiator Thermostat
About this product
The Wiser radiator thermostat (hereinafter referred to
as ) uses integrated temperature sensors thermostat
to control the ow of water through a radiator, thereby
regulating the temperature in a room. The target
temperature and switching times are set in the Wiser
App.
! Package contents
A Radiator Thermostat
B O-ring (pre-installed)
C Chrome ring nut
D Danfoss RAVL
E Danfoss RA
F Danfoss RAV
G M30 x 1.5 valve adapter
H M4 hex nut
I M4 x 11.5 mm screw
J AA battery (pair)
K Installation guide
“ Removing the old radiator thermostat
Open the valve of the radiator thermostat to ‘max’
to facilitate removal. Unscrew ring nut and remove
thermostat.
Note: For other manufacturers please follow their
guidelines on how to remove the old radiator
thermostats.
§ Inserting the batteries
• When inserting batteries, observe the correct
polarity.
• Do not use rechargeable batteries.
A QR Code label
TIP: The QR code is used for secured Zigbee
commissioning which is an option in some Zigbee 3.0
systems. We strongly recommend not to remove this
label in case future commissioning is required.
A
B
C
D
E
F
G
HJ K
$ Install the adapter and thermostat
NOTICE
RISK OF DAMAGE TO EQUIPMENT
• Make sure that the O-ring is seated rmly on the
thread.
• Tighten the ring nut ensuring that the assembly is
not overtightened.
Failure to follow these instructions can result in
equipment damage.
Follow the installation steps for the type of adapter
you have.
A M30 x 1.5mm adapter
(1) Place the M30 adapter on the valve.
(1) Loosely screw the ring nut onto the valve
adapter.
(2) Screw on the thermostat and tighten.
B Danfoss RAVL to M30 adapter
(1) Place the Danfoss RAVL on the valve.
(3) Place the M30 adapter on the Danfoss RAVL.
(4) Loosely screw the ring nut onto the valve
adapter.
(5) Screw on the thermostat and tighten.
C Danfoss RA to M30 adapter
(1) Place the Danfoss RA on the valve.
(2) Assemble M4 hex nut and M4 x 11.5 screw to
tighten the Danfoss RA adapter onto the valve.
(3) Place the M30 adapter on the Danfoss RA.
(4) Loosely screw the ring nut onto the valve
adapter.
(5) Screw on the thermostat and tighten.
D Danfoss RAV to M30 adapter
(1) Break spindle adapter from the side of Danfoss
RAV.
(2) Place spindle adapter on the top of the valve
spindle and push fully on.
(3) Place the Danfoss RAV on the valve.
(4) Assemble M4 hex nut and M4 x 11.5 screw to
tighten the Danfoss RA onto the valve.
(5) Place the M30 adapter on the Danfoss RAV.
(6) Loosely screw the ring nut onto the valve
adapter.
(7) Screw on the thermostat and tighten.
NOTE: To align the LEDs in the desired position:
slightly loosen the ring nut, turn the thermostat to the
desired position and tighten the ring nut again.
% Read full device guide online
Scan the QR code and choose your language
for complete information about the device, including
operation, conguration and using the product with a
Wiser system.
Technical data
Power supply: 2x 1.5 V IEC LR6 (AA) alkaline
batteries
Without power supply: Connection data retained
Temperature setting range: 5 °C to 30 °C
Temperature resolution: 0.5 °C
Control accuracy: < 0.8 °C at 4 °C/h
Surface temperature at place
of installation:
max. 93 °C
Water temperature: max. 110 °C,
max. continuous 73 °C
Ambient operating
temperature:
0 °C to 45 °C
Storage temperature: -20 °C to 65 °C
Transportation temperature: -20 °C to 65 °C
Operating frequency: 2.4GHz
Max. radio frequency power
transmitted:
max. 20mW (13dBm)
Degree of contamination: 2
Radio range: 30 m free eld
Energy class: IV - 2%
Software class: A
Protection rating IP 30
Dimensions (HxØ): 93 x 51mm
Communication protocol: Zigbee 3.0 certied
Trademarks
• Wiser™ is a trademark and the property of
Schneider Electric SE, its subsidiaries and aliated
companies.
• Zigbee®
is a registered trademark of the
Connectivity Standard Alliance.
Other brands and registered trademarks are properties
of their relevant owners.
EU Declaration of Conformity
Hereby, Schneider Electric Industries, declares
that this product is in compliance with the essential
requirements and other relevant provisions of RADIO
EQUIPMENT DIRECTIVE 2014/53/EU. Declaration of
conformity can be downloaded on: se.com/docs.
Schneider Electric Industries SAS
If you have technical questions, please contact the
Customer Care Centre in your country.
se.com/contact
A
A
„ §
21
A
B
3
2
C
D
21
1
2
3
1
4
3
4
5
I
3
4
5
6 7
da
06490332001 Iss B
Produktspecifikationer
| Varumärke: | Schneider |
| Kategori: | Termostat |
| Modell: | CCTFR6100Z3 |
Behöver du hjälp?
Om du behöver hjälp med Schneider CCTFR6100Z3 ställ en fråga nedan och andra användare kommer att svara dig
Termostat Schneider Manualer
27 September 2024
30 Augusti 2024
24 Augusti 2024
22 Augusti 2024
10 Augusti 2024
3 Augusti 2024
2 Augusti 2024
1 Augusti 2024
Termostat Manualer
- Schwaiger
- PECO
- Intergas
- Warmup
- TrickleStar
- Heatmiser
- Plugwise
- Kidde
- HomePilot
- Johnson Control
- Gewiss
- Weishaupt
- Airwell
- Nexa
- Muller
Nyaste Termostat Manualer
13 Oktober 2025
12 Oktober 2025
12 Oktober 2025
5 Oktober 2025
2 Oktober 2025
2 Oktober 2025
29 September 2025
28 September 2025
28 September 2025
28 September 2025