Sloan WES-4000 Bruksanvisning

Sloan toalett WES-4000

Läs gratis den bruksanvisning för Sloan WES-4000 (2 sidor) i kategorin toalett. Guiden har ansetts hjälpsam av 16 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 8.5 recensioner. Har du en fråga om Sloan WES-4000 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/2
OR LESS TRIM
13 ¾" ¼"
13 ½ ½
13 ¼ ¾
13 1
12 ¾
12 ½
12 ¼
12 2
11 ¾
11 ½
11 ¼
11 3
10 ¾ 3 ¼
10 ½ 3 ½
OR LESS TRIM
10 ¼" 3 ¾"
10 4
9 ¾ 4 ¼
9 ½ 4 ½
9 ¼ 4 ¾
9 5
8 ¾" 5 ¼
8 ½ 5 ½
8 ¼ 5 ¾
8 6
7 ¾ 6 ¼
7 ½ 6 ½
7 ¼ 6 ¾
7 7
OR LESS TRIM
6 ¾" 7 ¼"
6 ½ 7 ½
6 ¼ 7 ¾
6 8
5 ¾ 8 ¼
5 ½ 8 ½
5 ¼ 8 ¾
5 9
4 ¾ 9 ¼
4 ½ 9 ½
4 ¼ 9 ¾
4 10
1-888-SLOAN-14 (888-756-2614)
customer.service@sloanvalve.com
CUSTOMER SERVICE
INCORRECT
Not centered
CORRECT
Centered
A
½" to ¾"
9¾"
for ADA
installation
standard 24" rim
finished oor
16 ¾"
11
10
12
1234
Arrow
tab UP
1234
A
C
B
D
E
CAR TRIDGE
INSTR UCTIONS
The information in this document is subject to change without notice.
©2014 Sloan Valve Company All rights reserved.
0816498 Rev. 3 (07-14)
sloanvalve.com
CAUTION After removing any urinal from the
drain line, it’s normal for certain naturally occurring
but potentially hazardous sewer gases to escape
through the opening until the waterless cartridge
is installed properly into the waterless urinal. If you
need to leave an open drain line unattended after
removing the urinal from the wall, temporarily wedge paper towels or a
rag into the drain hole to reduce any outflow of sewer gases, and remove
the paper towels or rag prior to completing the urinal or cartridge
installation. Never smoke, have an open flame, or place your nose or
mouth near open drain lines or waterless urinal housings into which
a cartridge is not yet properly installed. You also can wear a breathing
mask when removing or installing any waterless urinal or cartridge to
reduce potential exposure to any such gases.
B
14
15
4
13
3
12
8
2
10 11
9
7
5
1
C D
WES-4000 WATERFREE URINAL
NEW CONSTRUCTION
INSTALLATION INSTRUCTIONS
BEFORE STARTING INSTALLATION:
IMPORTANT - Do not install on copper DWV
due to copper’s susceptibility to corrosion.
Check rough-in height to achieve 24” rim height
(17” rim height for ADA).
Check slope. Downhill slope, per code, is
essential because of waterfree urinals depend
on gravity flow.
Check DWV material. Suitable materials include
cast iron, PVC, ABS, and galvanized steel.
Shut o water supply and cap the nipple with
the 3/4” chrome cap (provided).
.
TUBE CUTTING CHART
Measure drain nipple depth (in) to find trim
length (in)
13 7/8” or more DO NOT CUT
3 3/4” or less DO NOT USE TUBE
CARRIER STUD PLACEMENT If using in-wall
carrier, set bearing as shown above.
A. Clean face of existing wall flange.
B. Install the brass flange with the clean
inspection disc.
C. Slowly pour water into the drain.
D. Use a flashlight to check the pitch/slope.
There should be no water present in the
inspection disc or nipple.
E. Remove flange after inspection.
ADJUST DRAIN TO ACHIEVE PITCH If standing
water is present (code requires 1/4” drop per
foot of drain line for proper pitch). Seal wall
according to code.
MEASURE & MARK THE ROUGH-IN If in-wall
carrier is not used. Use a 5/16” masonry bit to
drill hole, then install the hanger bracket with
one plastic anchor and screw.
A. Hang the bowl on the bracket and check tall
pipe alignment, then remove the bowl and
adjust the bracket as needed.
Re-hang and re-check bowl alignment with
drain line. Tail pipe should align with center or
drain line.
B. Mark anchor holes then remove
bowl without moving hanger
bracket.
DETERMINE THE DRAIN NIPPLE DEPTH by
measuring the distance between the back of the
sanitary tee (or elbow) to the front edge of the
nipple.
A. Find the drain nipple depth on the Tube
Cutting Chart (left).
Measure and mark the specified trim length on
the insert tube at the nearest 1/4” groove.
B. Cut the tube at the groove using a sharp
utility knife to ensure a square, flat cut.
C. Clean burrs from the cut end by using emery
paper.
D. Apply lubricant to the outside of the rubber
brushing and ribbed inside area.
E. Insert the tube and brushing with arrow tab at
the top. Apply lubricant to tailpipe of housing.
PLACE THE GEAR CLAMP and
compression nut onto the housing
tailpipe.
DRILL HOLES with 5/16”
masonry bit for the lower
anchor screws and insert
plastic anchors.
HANG THE BOWL inserting
tailpipe into brushing, then install
anchor screws with washers.
TIGHTEN FLANGE BOLTS.
TIGHTEN
COMPRESSION
NUT AND GEAR
CLAMP.
POUR 5
GALLONS OF
WATER as
rapidly as
possible into
housing to
ensure good
flow and no
leaks or
standing water.
CAULK THE BOWL TO
THE WALL.
INSTALL THE
CARTRIDGE per the
cartridge instruction
sheet.
SET DRAIN LINE HEIGHT 17 from
finished floor (standard 24 rim) or 10” for
ADA installation. Threaded nipple should
extend ½ to ¾ from wall.
1
1"
14¼
Drain
14¼"
Install plastic anchor
and screw here
6


Produktspecifikationer

Varumärke: Sloan
Kategori: toalett
Modell: WES-4000

Behöver du hjälp?

Om du behöver hjälp med Sloan WES-4000 ställ en fråga nedan och andra användare kommer att svara dig