Läs gratis den bruksanvisning för Texas Instruments LM5066 (66 sidor) i kategorin ej kategoriserat. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 5.0 stjärnor baserat på 3 recensioner. Har du en fråga om Texas Instruments LM5066 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/66
OUT
UVLO/EN
VIN
GATE
DIODE
R
3
FB
OVLO
SDAI
SCL
PGD
SENSE
VDD
SMBus
Interface
SMBA
CL
RETRY
VAUX
VDD
VREF
TIMER
PWR
AGND
LM5066
V
OUT
C
OUT
V
IN
1 PF
1 PF
R
PWR
ADR2
ADR1
ADR0
VIN_K
GND
SDAO
R
SNS
R
4
R
1
C
TIMER
R
5
R
6
C
IN
Z
1
D
1
Q
2
Q
1
R
2
48-V Bus
12 V
PMBus Hotswap
Manages Inrush,
Faults, and
Monitoring
Load 1Load 2
Micro
Controller
I/V/P info
via PMBus
Regulate Loads to
Optimize Efficiency
Plug-in Card
Card to Card Communication
DC/DC
48 V
Product
Folder
Sample &
Buy
Technical
Documents
Tools &
Software
Support &
Community
AnIMPORTANTNOTICEattheendofthisdatasheetaddressesavailability,warranty,changes,useinsafety-criticalapplications,
intellectualpropertymattersandotherimportantdisclaimers.PRODUCTIONDATA.
LM5066
SNVS655IJUNE2011REVISEDJANUARY2016
LM506610to80V,HotswapControllerWithI/V/PMonitoringandPMBus™Interface
1
1Features
1
10-to80-VOperation
100-VContinuousAbsoluteMax
26mV(±12%)or50mV(±6%)ILIMThreshold
ProgrammableFETSOAProtection
ProgramableUV,OV,t
FAULT
Thresholds
ExternalFETTemperatureSensing
FailedFETDetection
I
2
C/SMBusInterface
PMBus™CompliantCommandStructure
PrecisionV
IN
,V
OUT
,I
IN
,P
IN
,V
AUX
Monitoring
V(±2.7%);I(±3%);P(±4.5%)
ProgramableI/V/PAveragingInterval
12-bitADCwith1-kHzSamplingRate
–40°C<T
J
<125°COperation
Pin-to-PinCompatiblewithLM5066I
2Applications
48-VServers
BaseStationPowerDistribution
NetworkingRoutersandSwitchers
PLCPowerManagement
24-to28-VIndustrialSystems
3Description
LM5066providesrobustprotectionandprecision
monitoringfor10-to80-Vsystems.Programmable
UV,OV,I
LIMIT
,andfast-shortcircuitprotectionallow
forcustomizedprotectionforanyapplication.
ProgrammableFETSOAprotectionsetsthe
maximumpowertheFETisallowedtodissipate
underanycondition.Theprogrammablefaulttimer
(t
FAULT
)issettoavoidnuisancetrips,ensurestart-up,
andlimitthedurationofoverloadevents.
Inadditiontocircuitprotection,theLM5066supplies
real-timepower,voltage,current,temperature,and
faultdatatothesystemmanagementhostthrough
theI
2
C/SMBusinterface.PMBuscompliant
commandstructuremakesiteasytoprogramthe
device.Precisiontelemetryenablesintelligentpower
managementfunctionssuchasefficiency
optimizationandearlyfaultdetection.LM5066also
supportsadvancedfeaturessuchasI/V/Paveraging
andpeakpowermeasurmenttoimprovesystem
diagnostics.
LM5066Iispin-to-pincompatiblewiththeLM5066
andoffersimprovedtelemetryaccuracyandsupports
theRead_Eincommandtomonitorenergy.See
Table1foradetailedcomparison.
DeviceInformation
(1)
PARTNUMBERPACKAGEBODYSIZE(NOM)
LM5066PWP(28)9.70×4.40mm
2
(1)Forallavailablepackages,seetheorderableaddendumat
theendofthedatasheet.
SPACE
SimplifiedSchematic
LM5066inaPlug-inCard

Betygsätt denna manual

5.0/5 (3 Recensioner)

Produktspecifikationer

Varumärke: Texas Instruments
Kategori: ej kategoriserat
Modell: LM5066

Behöver du hjälp?

Om du behöver hjälp med Texas Instruments LM5066 ställ en fråga nedan och andra användare kommer att svara dig