Vemer Energy-400R PWR Bruksanvisning
Läs gratis den bruksanvisning för Vemer Energy-400R PWR (1 sidor) i kategorin mätning. Guiden har ansetts hjälpsam av 11 personer och har ett genomsnittsbetyg på 3.8 stjärnor baserat på 6 recensioner. Har du en fråga om Vemer Energy-400R PWR eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/1

V3IS00384-011
Mod. ENERGY-400R PWR
Mod. ENERGY-400R PWRi
Static meter in standard dimensions 72x72 mm to read active energy
consumption in three-phase 400V systems:
-forENERGY-400RPWR:currentinputsbyshunt;
-forENERGY-400RPWRi:currentinputsbycoils with galvanic insulation
betweenprimaryandsecondary.
AmperometricconnectionbyCT x/5A.
SAFETY WARNINGS
To guarantee correct installation, proceed as follows:
1) The appliance should be installed by a competent operator
2) The appliance should be installed in a panel in such a way as to
guarantee that the terminals are inaccessible after fitting
3) A protection device against over-currents should be installed in the
electrical system, upstream of the energy meter
4) Connect the instrument as shown in the alongside diagrams
5) Before touching the connector terminals make sure that the wires to
be connected or already connected to the instrument are not live
6) Touch the dip-switches only when the instrument is not powered
7) Do not power or connect the instrument if any part of it is damaged
Code Model Description
VE010500 ENERGY-400RPWR Three-phaseenergymeter
VE011300 ENERGY-400RPWRi Three-phaseenergymeter
TECHNICAL SPECIFICATIONS
• Powersupplyvoltage:
3x230phase-neutral(400phase-phase)VCA(-15%/+10%)50/60Hz
• Inputcurrent:I
n
= 5A; I
MAX
=6A
• Minimumstart-upcurrent:15mA
• Accuracy:class2tostandardsEN62053-21
• Maximumpowerconsumption:voltagecircuits<2,5VA
currentcircuits<2,5VA
• Galvanicallyisolatedamperometricinput(for PWRi model only)
• AmperometricconnectionbyCTx/5A
• Selectabletransformationratios(forCTx/5A):5-10-25-50-75-100-125-150-200-
250-300-400-500-600-800-1000/5
• Operatingtemperature:-10÷+45°C
• Relativehumidity:10%÷90%noncondensing
• Storagetemperature:-20÷+60°C
• Signalingleds:green=poweron
red = flashing at 1/4 kWh
yellow = when lit the instrument detects 1/4 kWh negative
(probableincorrectentry)andremainslituntil1/4kWh
positive is detected
• Optoinsulatedpulseoutputforenergyconsumptionremote-monitoring
(1kWh/pulse)
• Pulsespecications: duration=100ms±15%
voltage=9÷24VCC(±10%)
switchableoutputcurrent20mAmax
• Protectiondegree:IP20
• Enclosure:standarddimensions72x72mm
INSTRUMENT DESCRIPTION
7-digit mechanical counter: resolution 1 kWh
Green warning light: lights up to indicate power on
Red warning light: every flash corresponds to an energy count of 1/4 kWh
Yellow warning light: when lit the instrument detects 1/4 kWh negative
(probableincorrectentry)andremainslituntil1/4kWhpositiveisdetected
Dip-switch1-2-3-4forCTsetting.Dip-switch5-6notused
GUIDE TO INSTALLATION
1) Beforeinstallingtheinstrument,selectthetransformationratiorequired.
Useanx/5AouterCTwithatransformationratiofromamongthosesetout
inthedescriptionbox. ,theCTsecondariesmaybeFor model PWRi only
connected to earth.
2) Theinstrumentshouldbeconnectedasshownintheconnectiondiagrams,
inaccordancewiththeCTenergydirections.
3) Iftheerroristofallwithintheclasslimitsoftheinstrument,itisnecessaryto
usethecurrenttransformerinitslinearoperatingeld.
Seetheprecisionbox:
-MaximummeasurementerrorinaccordancewithEN62053-21forclass2
meters with cos ;ϕ=0,5inductive(A)
-MaximummeasurementerrorinaccordancewithEN62053-21forclass2
meters with cos = 1 and voltage and frequency reference conditions .ϕ(B)
4) Iftheinstrumentisactive,thepowershouldbeswitchedofftochangetheCT
ratio.
REFERENCE STANDARDS
ConformitytotheEUdirectives:
73/23/ECCmodiedby (LowVoltage)93/68/ECC
89/336/ECCmodiedby92/31/ECC and 93/68/ECC(E.M.C.)
is declared with reference to the following harmonised standard:
EN61010-1,EN61000-6-2,EN61000-6-3,EN62053-21andEN62052-11
User Manual
ACTIVE ENERGY METER
Read all the instructions carefully
Dimensions
Connection diagrams
Description
Accuracy
72
&OFSHZ3183
L8I
0/ L8I
4XJUDI*O"_
$M
Y7_
)[
L8I*NQ
{£Èääää
0/
0''
105
5
66
8
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
5" 5" 5" 5"
0''
0/
&OFSHZ3183
L8I
0/ L8I
4XJUDI*O"_
$M
Y 7_
)
L8I*NQ
{£Èääää
0/
0''
" #
6OEFUFSNJOFEFSSPS[POF 6OEFUFSNJOFEFSSPS[POF
L3
L1
L1
V1
N
I +1
I -1
L2
L3
I +2
I -2
I +3
I -3
V2V3
L2
N
N
I 20 mA≤
9 24 V
CC÷
+
Pulse output
1 kWh/pulse
3 CT connection ( )
WITH or WITHOUT neutral (3 or 4 wires)
PWR/PWRi
L3
L1
L1
V1
I +1
I -1
L2
L3
I +2
I -2
I +3
I -3
V2V3
L2
I ≤ 20 mA
9 24 V
CC÷
+
Pulse output
1 kWh/pulse
2 CT connection ( only)
WITHOUT neutral (3 wires)
PWRi
PWR
PWRi
P1 P2
S1 S2
P1 P2
S1 S2
I
I
Produktspecifikationer
Varumärke: | Vemer |
Kategori: | mätning |
Modell: | Energy-400R PWR |
Behöver du hjälp?
Om du behöver hjälp med Vemer Energy-400R PWR ställ en fråga nedan och andra användare kommer att svara dig
mätning Vemer Manualer
31 Augusti 2025
31 Augusti 2025
27 Augusti 2025
27 Augusti 2025
27 Augusti 2025
27 Augusti 2025
mätning Manualer
- Stamos
- Steinberg
- Chauvin Arnoux
- Beha-Amprobe
- Makita
- Doyon
- Ade
- Mueller
- Osram
- Mitsubishi
- Voltcraft
- Extech
- Fluke
- Flex
- Emko
Nyaste mätning Manualer
11 Oktober 2025
8 Oktober 2025
8 Oktober 2025
8 Oktober 2025
7 Oktober 2025
7 Oktober 2025
7 Oktober 2025
7 Oktober 2025
7 Oktober 2025
7 Oktober 2025