Vimar 03991 Bruksanvisning
Läs gratis den bruksanvisning för Vimar 03991 (3 sidor) i kategorin Växla. Guiden har ansetts hjälpsam av 9 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 5 recensioner. Har du en fråga om Vimar 03991 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/3
                    
                    
                    
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com
03991-03992EN  03  2209
03991
03992
00932
00945.G
03991 - Magnetic Quid relay module with sequential ON/OFF pulses, 
1 input for NO push button, 1x10 A 220-240 V~ 50/60 Hz relay output, 
installation in junction boxes or connector block boxes.
The device, which can  be installed  in  connector  block  boxes  and placed  under-
neath the blank module or inside the junction boxes declared as suitable for electri-
cal devices that dissipate energy, turns a load on or off following a signal received 
from a push button.
03992 - Magnetic Quid relay module with sequential ON/OFF pulses, 
1  input  for  NO  push  button,  1  input  for  reset  push  button,  1x10  A 
relay output, 220-240 V~ 50/60 Hz power supply, light signal for the 
load  status  on  each  individual  push  button,  installation  in  junction 
boxes or connector block boxes.
The device, which can  be installed  in  connector  block  boxes  and placed  under-
neath the blank module or inside the junction boxes declared as suitable for electri-
cal devices that dissipate energy, turns a load on or off following a signal received 
from  a  push  button.  It  is  also  fitted  with  an  input  for  the  control  unit  switch-off 
control (reset). If the signalling unit 00932 is installed in the ON/OFF or reset control 
push button, the device sends a signal about the status of the load. 
00945.G, 00932 - Load status LED signalling unit, green.
The signalling unit is installed in the back of the push buttons associated with relay 
03992 and signals the status of the load both for the control push button and for 
the reset push button. Art. 00945.G is dedicated to the Linea series.
CHARACTERISTICS.
• Art. 03991:
-   Rated supply voltage: 220 – 240 V~ 50/60 Hz.
-   ON/OFF control via NO push buttons.
-   Max. 1 switching per second.
-   It should be used in dry, dust-free places at a temperature of between 0 °C and 
+35 °C.
-  Dissipated power:  1.5 W with load ON and max. current 10 A 
0 W and no absorption with load OFF
• Art. 03992:
-   Rated supply voltage: 220 – 240 V~ 50/60 Hz.
-   ON/OFF control via NO push buttons.
-   Max. 1 switching per second.
-   Reset control via NO push button. An unlimited number of art. 03992 (with or 
without signalling unit) can be connected to the same Reset push button. 
-  Art. 00932 for signalling the load status can be installed on the control and reset 
push button. 
-   An  unlimited  number  of  ON/OFF  control  push  buttons  can  be  connected  to 
each module 03992. Up to a maximum of 4 ON/OFF control push buttons with 
junction box pilot lamp can be connected. This lamp will only light up when the 
load is ON. 
-  Up to a maximum of 2 Reset push buttons with junction box pilot lamp can be 
connected to  each  module 03992  (for  instance,  with  2  modules  03992  con-
nected to  the same Reset  push buttons, 4 Reset  push buttons with junction 
box pilot lamp can be connected). The junction box pilot lamp will light up if one 
of the relays has the load ON. 
- On the ON/OFF control push button and on the reset push button we recommend 
you  use  buttons  art.  31000A.L-31000.L-31000A.D-31000.D  if  you  are  using 
signalling  unit  00945.G  or  buttons  20026-19026-14026-20021.L-19021.L-
14021.L if you are using unit 00932.  
-  In the event that several modules 03992 are connected together using the 
reset push button, the system must be set up with a single Hysteresis and/
or RCBO circuit breaker. 
-   It should be used in dry, dust-free places at a temperature of between 0 °C and 
+35 °C.
-   Dissipated power: 1.5 W with load ON and max. current 10 A
0 W and no absorption with load OFF
• Art. 00945.G-00932:
-   Rated supply voltage: 220 – 240 V~ 50/60 Hz.
-   The signalling unit can be installed on the ON/OFF and reset control push but-
ton.
-  The signalling unit can also be installed on controls that are not associated with 
module 03992. 
-   It should be used in dry, dust-free places at a temperature of between 0 °C and 
+35 °C.
WEEE - User information
The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of its life 
must be collected separately from other waste. The user must therefore hand the equipment at the end of its 
life cycle over to the appropriate municipal centres for the differentiated collection of electrical and electronic 
waste. As an alternative to independent management, you can deliver the equipment you want to dispose of 
free of charge to the distributor when purchasing a new appliance of an equivalent type. You can also deliver 
electronic products to be disposed of that are smaller than 25 cm for free, with no obligation to purchase, to 
electronics distributors with a sales area of at least 400 m 2. Proper sorted waste collection for subsequent 
recycling, processing and environmentally conscious disposal of the old equipment helps to prevent any pos-
sible negative impact on the environment and human health while promoting the practice of reusing and/or 
recycling materials used in manufacture.
CONTROLLABLE LOADS.
•   Relay output (220- 240 V~ controllable loads):
-   rated load in AC1: 10 A (6,000 cycles);
-   rated load in AC15: 2.2 A (5,000 cycles); 
-  resistive loads : 10 A (20,000 cycles);
-  incandescent lamps : 3 A (20,000 cycles);
-   fluorescent lamps : 100 W (20,000 cycles);
-   energy saving lamps  : 100 W (20,000 cycles);
-   LED lamps : 100 W (20,000 cycles);
-   electronic transformers : 2 A (20,000 cycles);
-   power supply units for LED strips: 200 W (20,000 cycles).
INSTALLATION RULES.
• Installation must be carried out by qualified persons in compliance with the cur-
rent  regulations  regarding  the  installation  of  electrical  equipment  in  the country 
where the products are installed.
• The power supply circuit (L-N) must be protected against overloads by installing 
a device, fuse or automatic 1-way switch, with a rated current not exceeding 10 
A.
• Since these are retrofit devices, art. 03991 and 03992 must always be installed 
in protected boxes.
REMOTE CONTROL RECEPTION.
Quid can be remote controlled using the following devices:
• DueFili+ video door entry system: Video Door App + art. 40507 + art. 69RH or 
69PH (programmed for 2 s timed actuation)
The DueFili+ system is designed to configure a timed actuation (relay art. 69RH 
or 69PH) and control it from video door entry indoor stations. If the indoor station 
is connected (art. 40507) actuation can be remote controlled via the Video Door 
App.
• IP video door entry system: Video Door App + art. 40607 +  art. 40636 (pro-
grammed for 2 s timed actuation)
The IP video door entry system is designed to configure a timed actuation (relay 
art.40636) and control it from video door entry indoor stations. If the indoor sta-
tion is connected (art. 40507) actuation can be remote controlled via the Video 
Door App.
• GSM thermostat 01913: the device is fitted with a programmable output to which 
an  auxiliary  supporting  relay  needs  to  be  connected  (a  common  one-position 
stable  relay  with  a  230V  coil  is  sufficient).  Actuation  is  then  controlled  via  the 
By-Phone App or the By-Clima App (or directly via SMS text message). 
REGULATORY COMPLIANCE.
LV Directive. EMC directive. EN 60669-2-1 standard.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces 
of lead.
Produktspecifikationer
| Varumärke: | Vimar | 
| Kategori: | Växla | 
| Modell: | 03991 | 
Behöver du hjälp?
Om du behöver hjälp med Vimar 03991 ställ en fråga nedan och andra användare kommer att svara dig
Växla Vimar Manualer
                        
                         1 April 2025
                        
                    
                                                            
                        
                         11 Mars 2025
                        
                    
                                                            
                        
                         11 Mars 2025
                        
                    
                                                            
                        
                         30 December 2025
                        
                    
                                                            
                        
                         30 December 2025
                        
                    
                                                            
                        
                         16 December 2024
                        
                    
                                                            
                        
                         16 December 2024
                        
                    
                                                            
                        
                         16 December 2024
                        
                    
                                                            
                        
                         16 December 2024
                        
                    
                                                            
                        
                         16 December 2024
                        
                    
                                                            Växla Manualer
- IPGARD
- Perel
- Mercusys
- Blustream
- CSL
- STI
- WHALE
- CYP
- Grandstream
- Roline
- Grasslin
- Dormakaba
- AV:link
- Totolink
- Maclean Energy
Nyaste Växla Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         7 April 2025
                        
                    
                                                            
                        
                         5 April 2025
                        
                    
                                                            
                        
                         5 April 2025
                        
                    
                                                            
                        
                         5 April 2025
                        
                    
                                                            
                        
                         5 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         2 April 2025