Watts Chrono Battery BT 051 Bruksanvisning


Sidor 2 Engelska Termostat

Läs bruksanvisningen för Watts Chrono Battery BT 051 gratis online eller ladda ner PDF:en. Bruksanvisningen har visats 38 gånger. Fråga om modellen? Ställ en fråga

Operating temperature
0°C - 50°C (or 32°F – 122°F)
Comfort / Reduction mode
setting temperature range
5°C – 35°C (or 41°F - 95°F)
Daily clock programmable
24H with 15 minutes step
Weekly clock programmable
7 days with 1 hour step
Regulation
characteristics
Proportional band 2°K for 10min cycle
Electrical Protection
Class II - IP30
Power Supply
Battery operated life
2 x AA LR06 1.5V
> 1 year (For Alkaline type)
Output
Relay output => 1RT Free contact (8(3)A 250Vac )
PPL IMP 1083B
USER GUIDE
GB
SELECT MODE
Thermostat “Chrono Battery” Electronic Daily BT 050
Thermostat “Chrono Battery” Electronic Weekly BT 051
TECHNICAL CHARACTERISTICS
MODES DESCRIPTION
- Electronic thermostat with mechanical clock.
- Possibility to set day and night temperature.
- Daily or Weekly program.
- 3 positions switch : Clock – Reduction Mode – Comfort
- Relay output (free contact)
-Clock mode:The system follows the temperature set by the
and knobs, according to the program clock.
- Reduction mode:The system follows the temperature set
by the knob.
- Comfort mode:The system follows the temperature set
by the knob.
Reduction temperature
setting.
Programmable
clock.
Comfort temperature
setting.
Select
mode.
Batteries
compartment
PROGRAMMABLE CLOC
K
Daily programmable clock Weekly programmable clock

Betygsätt denna manual


Produktspecifikationer

Varumärke: Watts
Kategori: Termostat
Modell: Chrono Battery BT 051

Behöver du hjälp?

Om du behöver hjälp med Watts Chrono Battery BT 051 ställ en fråga nedan och andra användare kommer att svara dig