Westinghouse WH50BBU Bruksanvisning

Westinghouse pump WH50BBU

Läs gratis den bruksanvisning för Westinghouse WH50BBU (12 sidor) i kategorin pump. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 2 recensioner. Har du en fråga om Westinghouse WH50BBU eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/12
OWNER’S MANUAL
COMPACT PRIMARY AND BACKUP PUMP SYSTEM
Model# WH50BBU
and Westinghouse are trademarks of Westinghouse Electric Corporation. Used Under License by Westinghouse
Residential Pumps. All Rights reserved.
2
PERFORMANCE
GPH at total feet of lift
Series HP 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. MAX LIFT
Primary Pump 1/2 5200 4650 4200 3650 3000 2200 30 ft.
GPH at total feet of lift
Series HP 0 ft. 5 ft. 10 ft. 15 ft. MAX LIFT
Backup Pump / 2700 2100 1500 600 20
Electrical & Switch Specifications
Series HP
Motor Full Load
(Amps)
Branch Circuit Req.
(Amps)
Primary Pump 1/2 7.6
15
Backup Pump
/
NA
SAFETY INSTRUCTIONS
1. Do not pump flammable or explosive liquids such as oil, gasoline, kerosene, ethanol, etc. Do not use in the
presence of flammable or explosive vapors. Using this pump with or near flammable liquids can cause an
explosion or fire, resulting in property damage, serious personal injury, and/or death.
2. ALWAYS disconnect the power to the pump before servicing.
3. Do not touch the motor housing during operation. The motor is designed to operate at high temperatures. Do not
disassemble the motor housing.
4. Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface, or in water
before disconnect the power.
5. Release all pressure and drain all water from the system before servicing any component.
6. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing
personal injury, and/or property damage.
7. Extension cords may not deliver sufficient voltage to the pump motor. Extension cords present a life threatening
safety hazard if the insulation becomes damaged or the connection ends fall into water. The use of an extension
cord to power this pump is not permitted.
8. Wear safety goggles at all times when working with pumps.
9. This unit is designed only for use on 115 volts (single phase), 60 Hz, and is equipped with an approved 3-
conductor cord and 3-prong grounded plug. Do not remove the ground pin under any circumstances. The 3-prong
plug must be directly inserted into a properly installed and grounded 3-prong, grounding-type receptacle. Do not
use this pump with a 2-prong wall outlet. Replace the 2-prong outlet with a properly grounded 3-prong receptacle
(a GFCI outlet) installed in accordance with the National Electrical Code and local codes and ordinances. All
wiring should be performed by a qualified electrician.
10. Protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not use
damaged or worn cords.
11. Failure to comply with the instruction and designed operation of this unit may void the warranty. ATTEMPTING TO
USE ADAMAGED PUMP can result in property damage, serious personal injury, and/or death.
12. Ensure that the electrical circuit to the pump is protected by a 15 Amp fuse or circuit breaker.
13. Do not lift the pump by the power cord.
14. Know the pump and its applications, limitations, and potential hazards.


Produktspecifikationer

Varumärke: Westinghouse
Kategori: pump
Modell: WH50BBU

Behöver du hjälp?

Om du behöver hjälp med Westinghouse WH50BBU ställ en fråga nedan och andra användare kommer att svara dig