Blebox gateBox Bruksanvisning
                    Blebox
                    
                    Inte kategoriserad
                    
                    gateBox
                
                                
    Läs gratis den bruksanvisning för Blebox gateBox (4 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 36 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 18.5 recensioner. Har du en fråga om Blebox gateBox eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/4
                    
                    
                    
Apply the safety systems described in the PN-EN 13241 standard 
dening the safety requirements and operational requirements 
for gates and barriers.
SAFETY RULES 
Connect only in accordance with the diagram presented in the 
manual. Improper connections may be dangerous, it can damage 
the controller, and loss of the warranty.
Connecting the device to a power supply that does not meet the 
quality requirements specied in EN 50081-1, EN 50082-1, UL508, 
EN 60950 will invalidate the warranty.
DANGER! Risk of electric shock! Even with the device turned o, 
the outputs may be live. All assembly work should be ALWAYS 
performed with the disconnected power circuit.
GARAGE, SLIDING AND SWING GATES AND DOOR CONTROLLER
Disconnect the installation supply voltage before installing the controller. 
Remember that any mounting works should be carried out when the mains 
voltage is disconnected (switch o the mains fuse or disconnect the power 
cord from the mains socket).
1
INSTALLATION - BASICS
The controller should be installed in a place protected against adverse 
environmental conditions, protected from third party access - in the ush box 
or inside the enclosure of the controlled device. Remember that metallic 
elements (wires, housing parts) have a negative inuence on the range of the 
device, and consequently the comfort of use. It is recommended that the 
device be mounted in a stable and xed position.
Read the diagram and then proceed to install the controller. Pay particular 
attention to the designation of the controller connectors. Start by connecting 
the + 12V / + 24V power wires (red or black with a white dotted line) and GND 
(black).
Paying attention to the polarity, connect the inputs controlling the engine 
control panel. Depending on the control panel, will be necessary to connect 
one or two inputs. The controller output O1 is destined for control in the open 
/ stop / close mode. The O2 output is an auxiliary output, applicable in the 
control panel requiring a connection stop circuit when the motor works, or 
may be used as an additional function, e.g. "wicket" if the control panel is 
equipped with this functionality.
control with μWiFi technology
from any place in the World
CONNECTION DIAGRAM
If the motor has electromechanical limits switch, it is possible to receive 
feedback from the controller, indicating the position of the motor in the 
positions "Open" (intermediate position) "Closed". To do this, connect one of 
the pins IN1 of the controller to the connector of the motor control panel 
which indicates the closed position of the motor (usually FTC, SWC, FC) on the 
other hand the second of the pins should be connected to the corresponding 
common signaling. One of the IN2 input pins should be connected to the 
connector indicating the open position of the motor (usually FCO, SWO, FA), 
while the other one should be connected to the corresponding common 
signaling. The connection polarity of the controller inputs is not signicant.
      IN1
5 - 24V
      IN2
12-24V
AC/DC
PWR
O2   
made in 
Europe
O1   
12 - 24V 
S1      S2
push-button
It is necessary to connect the right pin of the given output 
(O1 / O2) so that it has a higher potential than the left pin. 
In case of an inverted connection, due to the internal 
construction, it will connect the output which may cause 
the movement of the motor even without control it. In this 
situation, it is necessary to reverse the pair of wires 
connected inside output.
Pay attention to the maximum output current 
capacity - the control current cannot exceed 20mA 
per output. Overloading the output will cause 
irreparable damage to the controller.
Information advanced for installers in relation to the 
output polarity, when is connected to engines control 
panels for which the scheme is not available.
Produktspecifikationer
| Varumärke: | Blebox | 
| Kategori: | Inte kategoriserad | 
| Modell: | gateBox | 
Behöver du hjälp?
Om du behöver hjälp med Blebox gateBox ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Blebox Manualer
                        
                         18 September 2024
                        
                    
                                                            
                        
                         18 September 2024
                        
                    
                                                            
                        
                         18 September 2024
                        
                    
                                                            Inte kategoriserad Manualer
- Lancom
- Point 65
- Alutruss
- Hestan
- Séura
- ZKTeco
- Skan Holz
- QuickCool
- Warm Audio
- Smit Visual
- MEE Audio
- REV
- TTM
- AIC
- Plantronics
Nyaste Inte kategoriserad Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025