Läs gratis den bruksanvisning för Crestron DIN-KXI (4 sidor) i kategorin ej kategoriserat. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 3.9 stjärnor baserat på 2 recensioner. Har du en fråga om Crestron DIN-KXI eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/4

l
1M wide DIN rail mounting
l
Ethernet to KNX interface
l
Integrates KNX with a Crestron® control system
l
Supports KNXnet/IPSecurity (AES-128)
l
Controls up to 1,000 KNX datapoints
l
Up to 8 simultaneous KNXnet/IP Tunneling connections
l
Configure using ETS Software
l
On-board controls for setup and diagnostics
l
Powered via the KNX bus
The is an IP-based KNX interface that allows aDIN-KXI
4-Series® to communicate with a KNX system.Control System
It is capable of addressing and controlling up to 1,000
datapoints and receives power over the KNX bus. The DIN-KXI
can also be used as a programming interface for KNX devices
using ETS5 and ETS6 software.
KNX
KNX
KNX
KNXKNX Security
Security
Security
SecuritySecurity
The device supports KNX Security (AES-128) which can be
enabled using ETS software.
Ethernet
Ethernet
Ethernet
EthernetEthernet Communications
Communications
Communications
CommunicationsCommunications
The Ethernet connection allows access to the KNX bus from
any point on the LAN. This provides programming and
diagnostics without direct access to the DIN-KXI.
Local
Local
Local
LocalLocal Diagn
Diagn
Diagn
DiagnDiagnostics
ostics
ostics
osticsostics
The buttons and LEDs on the device provide diagnostic data
including the operating status and communication errors.
DIN
DIN
DIN
DINDIN Rail
Rail
Rail
RailRail Installation
Installation
Installation
InstallationInstallation
The 1M (18mm) wide DIN-KXI snaps onto a standard DIN rail
for installation in a wall mount enclosure. Wiring connections
are made along the top and bottom, clearly accessible from
the front for easy installation and servicing. All setup controls
and indicators are positioned on the center front panel.
DIN-KXI
DIN-KXI
DIN-KXI
DIN-KXIDIN-KXI
KNX Secure IPGateway, DINRailMount

Specifications
Specifications
Specifications
SpecificationsSpecifications
Power
Power
Power
PowerPower
KNX
KNX
KNX
KNXKNX Bus
Bus
Bus
BusBus 20mA
Communications
Communications
Communications
CommunicationsCommunications
KNX
KNX
KNX
KNXKNX KNX over TP (Twisted Pair);
Interface protocol: cEMI;
Max. APDU length: 55;
Device model: System B;
KNXnet/IP Security (AES-128);
Compatible with ETS5 and ETS6
Ethernet
Ethernet
Ethernet
EthernetEthernet Supports ARP, ICMP, IGMP, UDP/IP, TCP/IP,
DHCP, and Auto IP;
DHCP is enabled by default, can be changed
using the ETS Software
Connectors
Connectors
Connectors
ConnectorsConnectors
KNX
KNX
KNX
KNXKNX (2) 4-conductor KNX bus connectors, push-in
style;
Consisting of (1) Red (+) and (1) Black (-)
connector, for power and communications;
Accepts up to 4 solid-core twisted pairs;
0.6 - 0.8mm (22 - 20AWG), strip wires 5 -
6mm (0.2 - 0.24in.)
LAN
LAN
LAN
LANLAN (1) 8-pin RJ-45, female;
100BASE-TXEthernet port;
Green and yellow LEDs indicate Ethernet
port status
Controls
Controls
Controls
ControlsControls and
and
and
andand I
I
I
IIndicators
ndicators
ndicators
ndicatorsndicators
KNXPROG.
KNXPROG.
KNXPROG.
KNXPROG.KNXPROG. (1) Red LED and (1) recessed, miniature push
button for entering Programming mode and
factory reset;
Programming Mode: Press to enter
Programming mode, the LED lights to
indicate that Programming mode is
activated;
Factory reset: Press and hold while
connecting the KNX bus, hold for 6 seconds
until all LEDs flash
KNX
KNX
KNX
KNXKNX (1) Multicolor LED, indicates power and KNX
status;
Green: Indicates power is received from the
KNXbus;
Flashing Green Indicates communications on
the KNXbus;
Flashing Red: Indicates communications
failure on the KNX bus
MODE
MODE
MODE
MODEMODE (1) Multicolor LED, indicates BAOS and IP
tunnel status;
Green: Normal operating mode;
Red:Programming mode is active;
Flashes green (1 to 10 times): Manual mode
is active, the selected BAOS connection (1 to
10) is not used and is available, the number
of flashes indicates the connection number;
Flashes Orange (1 - 10 times): Manual mode
is active, the selected BAOS connection (1 -
10) is used;
Flashes Green (1 - 5 times): Manual mode is
active, the selected Tunnel (1 - 5) is not used
and is available;
Flashes Orange (1 - 5 times): Manual mode is
active, the selected Tunnel (1 - 5) is used;
Flashes Red: The configuration is not
properly loaded
IP
IP
IP
IPIP (1) Multicolor LED, indicates Ethernet
status;
Green: Active Ethernet link and valid IP
settings;
Flashes green: Ethernet activity;
Red:Invalid IP settings or has not received IP
settings from the DHCP server
CONNBAOS
CONNBAOS
CONNBAOS
CONNBAOSCONNBAOS (1) push button, to enter Manual mode and
select a BAOS connection;
Press to enter Manual mode and select a
BAOS connection (1 - 10), the MODE LED
indicates the selected BAOS connection
number;
To exit Manual mode, press CONN BAOS
and CONN TUNN simultaneously
CONNTUNN
CONNTUNN
CONNTUNN
CONNTUNNCONNTUNN (1) push button, to enter Manual mode and
select a tunnel connection;
Press to enter Manual mode and select a
TUNN connection (1 - 5), the MODE LED
indicates the selected tunnel connection
number;
To exit Manual mode, press CONN BAOS
and CONN TUNN simultaneously
Environmental
Environmental
Environmental
EnvironmentalEnvironmental
Temperature
Temperature
Temperature
TemperatureTemperature -5° to 45°C (23° to 113°F)
Humidity
Humidity
Humidity
HumidityHumidity 5% to 93% RH (noncondensing)
Construction
Construction
Construction
ConstructionConstruction
Enclosure
Enclosure
Enclosure
EnclosureEnclosure Light gray polycarbonate housing with
polycarbonate label overlay
Mounting
Mounting
Mounting
MountingMounting 35mm DIN EN 60715 rail mount, DIN 43880
form factor for enclosures with 45mm front
panel cutout, occupies 1 DINmodule space
(18 mm)
DIN-KXI
DIN-KXI
DIN-KXI
DIN-KXIDIN-KXI
KNX Secure IPGateway, DINRailMount

Dimensions
Dimensions
Dimensions
DimensionsDimensions
Height
Height
Height
HeightHeight 91 mm (3.57 in.)
Width
Width
Width
WidthWidth 18 mm (0.70 in);
1M wide
Depth
Depth
Depth
DepthDepth 60 mm (2.36 in.)
Weight
Weight
Weight
WeightWeight
40 g (1.41 oz)
Compliance
Compliance
Compliance
ComplianceCompliance
Regulatory Model: M202234003
CE
Model
Model
Model
ModelModel
DIN-KXI
KNX Secure IPGateway, DINRailMount
Available
Available
Available
AvailableAvailable Accessories
Accessories
Accessories
AccessoriesAccessories
For a list of available accessories, visit the productDIN-KXI
page.
This product may be purchased from select authorized Crestron dealers and
distributors. To find a dealer or distributor, please contact the Crestron sales
representative for your area. A list of sales representatives is available online at
www.crestron.com/How-To-Buy/Find-a-Representative or contact us for
additional information by visiting forwww.crestron.com/contact/our-locations
your local contact.
The original language version of this document is U.S. English.
All other languages are a translation of the original document.
The product warranty can be found at .www.crestron.com/warranty
The specific patents that cover Crestron products are listed online at
www.crestron.com/legal/patents.
Certain Crestron products contain open source software. For specific
information, please visit .www.crestron.com/opensource
Crestron, the Crestron logo, and 4-Series are either trademarks or registered
trademarks of Crestron Electronics, Inc. in the United States and/or other
countries. Other trademarks, registered trademarks, and trade names may be
used in this document to refer to either the entities claiming the marks and
names or their products. Crestron disclaims any proprietary interest in the
marks and names of others. Crestron is not responsible for errors in typography
or photography.
Specifications are subject to change without notice.
©2024 Crestron Electronics, Inc.
Rev 03/28/24
DIN-KXI
DIN-KXI
DIN-KXI
DIN-KXIDIN-KXI
KNX Secure IPGateway, DINRailMount
Produktspecifikationer
Varumärke: | Crestron |
Kategori: | ej kategoriserat |
Modell: | DIN-KXI |
Behöver du hjälp?
Om du behöver hjälp med Crestron DIN-KXI ställ en fråga nedan och andra användare kommer att svara dig
ej kategoriserat Crestron Manualer
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
ej kategoriserat Manualer
- IMG Stageline
- Chamberlain
- Seagate
- Fantini Cosmi
- SoundTube
- Carson
- Vishay
- Ade
- Genaray
- Entes
- Pyle
- Deltana
- EMOS
- Beaba
- Metabo
Nyaste ej kategoriserat Manualer
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025