Läs gratis den bruksanvisning för Drayton Digistat 2290M (4 sidor) i kategorin Termostat. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 4.5 stjärnor baserat på 2 recensioner. Har du en fråga om Drayton Digistat 2290M eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/4
Programmable Room
Thermostat
Installation Guide
Digistat
3r Generationd
(Fi 3)g
3 .a Complete the wiring ac cording to the conn ction e
suggestions
Model:
2290M
Technical Helpline Tel: 0333 6000 622
Website: www.draytoncontrols.co.uk
Email: customer.care@draytoncontrols.co.uk
User nd InstallationGuide06490309001Iss a E
BeforeInstallation
If you do not have the knowledge to install the thermostat
safely then you must arrange for a competent electrician or
heating egineer to install it for you. Wiring must conform to the
current IEE regulations.
Prior to commencing the installation you must ensure the
mains supply is switched off.
1. Remove the front cover by releasing the 2 screws at the
bottom. Mounting holes and electrical connections are
found underneath the hinged black cover (Fig 1).
(
Fig 1)
(Fig 2)
2. Fix back plate directly onto the wall using suitable wall plugs
and screws or mount over existing wall box (Fig 2).
(Fig 4)
3b. If your boiler supports OpenTherm please follow these
instructions:
RemovetheOpenThermcables from
the existing controller or
thermostat. Connect the cables to the OpenTherm terminals
OT1 and OT2 on th . Polarity is not important.e Digistat
Wire L and N from a separate supply with a 3A fuse.
Note that when connected to an OpenTherm boiler, Installer
Options 06 Valve Protection and 08 Application Type are not
available. The following options will appear in the Installer
Options list:
4
. Close the black hi
nged terminal cover and replace the front
cover by locating the two latches at the top then fasten the 2
screws at the bottom (Fig 4).
5. The is now installed and will automatically start to Digistat
control the room temperature.
10 Upper CH water set point 30-80°C Default 70°C
11 Lower CH water set point 10-2C Default 10°C
INSTA ER OPTIONSLL
To make s change to e th default Installer Option show below, s n
ente th Installe Option nu b pressing th setting tton r e r s me y e s bu
for 3 se onc ds. Thi allow acces t th User Men 01s s s o e u , the
Advance User Setting Men 02 th Installer Setting 03 and d s u , e s ,
Servic Interva Setting 04. Us th + an - e l s e e d button t scrol to s o l
Installe Options and press O to select You can exit the menu by r .
pressing til un you have d returne to the e hom screen. In the
Installer Options menu (Fig 5, scroll thro gh the options using u
th + an - e d button an pres ts d s O o select. Scrol thr ghl ou th
e
different settings using the + and - buttons and O press to
select and save. (Fig shows 6 Option 02 OFF).
(Option 01) Partial Assistant (beep)Sight
When enabled, audible tones indicate when the setpoint is
more than, less than or equal to the current room
temperature when a user manually adjusts the setpoint using
the + button: Setpoint > room temperature - single high tone
per 0.5°C increase Setpoint = room temperature - double tone
Setpoint < room temperature - single low tone per 0.5°C
decrease
(Option 02) Frost Protection
The Digistat will switch on the heating if the temperature falls
to 5°C and maintains a temperature of 7°C even when
in OFF mode.
(Option 03) Minimum Set Point Limit
Change minimum setpoint temperature. After any changes to
setpoint limits, all setpoints in AUTO, MANUAL, BOOST and
HOLIDAY modes will be modified to conform accordingly.
(Fig 5) (Fig 6)
(Option 04) Maximum Setpoint Limit
Change maximum setpoint temperature. After any changes to
setpoint limits, all setpoints in AUTO, MANUAL, BOOST and
HOLIDAY modes will be modified to conform accordingly.
(Option 05) Optimum Start
When enabled, this uses current ambient temperature, the
next scheduled setpoint and heat gain data captured by the
device to adjust the thermostat setpoint early, so the ambient
temperature is at the required level when the next event starts.
Delayed Start
When enabled, this uses current ambient temperature, current
event setpoint and heating characteristics of the environment
to delay implementation of the setpoint if the ambient
temperature is already close to it, therefore saving energy.
(Option 06) Valve Protection Time
In some hydronic heating systems it may be required to
protect the valve by operating it for a given time. When
enabled, this maintenance feature ensures that each relay
output is operated for at least one (1) minute each week.
(Option 07) Sensor Fault Function
In the event of a sensor fault, central heating output is
reduced to 30% by turning heating ON for 3 minutes, then
OFF for 7 minutes.
(Option 08) Application Type
Select the central heating system energy type.
(Option 09) System Capability
Select the flow capability of the heating system.
(Option 13) Installer Settings Lock
When enabled, you can lock the installer settings until a 3 digit
code is entered. If the code is forgotten while device is locked,
please call the Technical Helpline.
(Option 20) Reset (Service Interval settings are NOT reset)
Reset the Digistat to its original factory settings.
Service Interval Options continued on reverse.
What is it
What is it
What is it
What is itWhat is it
Select
Select
Select
Select Select between
between
between
betweenbetween
Default
Default
Default
DefaultDefault
Installer
Installer
Installer
Installer Installer Options
Options
Options
OptionsOptions
01
O
F
F O
N
ON
02
O
N
O
F
F
ON
03
5 High Limit
5
04
Low Limit 30
30
05
OFF Del Startayed Optim Startum
OFF
06
OFF 5 4 3 2 1
OFF
07
OFF ON
OFF
08
Gas Electric Oil Heat Pump
Gas
09
Fast Flow FlowNormal/Slow
Fast Flow
13
OFF ON
OFF
20
Partial Sight Assistant
F
rost Protection
Low Set Point C
High Set Point C
O
ptimum Start
Valve Protection Time (Mins)
Sensor Fault Function
Application Type
System Capability
Installer Settings
Lock Reset
NO YES
NO
Service Internal Options
Service Internal Options
Service Internal Options
Service Internal OptionsService Internal Options
01 Si Status
OFF ON
OFF
02 Si Type
Reduced Comfort Heating OFF No Effect
Reduced Comfort
03 Si Due Date
YY
/MM/DD
04 Si Warning
0 9
9
30
05 Si Due Alarm
OFF ON
OFF
06 Si Boost
OFF ON
07 Si Password Reset
Select 4-digit PIN
OFF
0000
Screen
Screen
Screen
ScreenScreen
Abbreviations
Abbreviations
Abbreviations
AbbreviationsAbbreviations
bEEP
FrSt
LoSP
HiSP
OPSt
vPrt
SEnS
APPL
SySt
LOC
rSEt
StAt
tYPE
dUE
WArn
ALAr
bSt
COdE
E
Xit
User Guide
INSTA ER OPTIONSLL - contin due
Pre- t Progra 1 (5-2dase m y w kend):ee
1Event 2 3 4 (5)* (6) (7) (8)
Time 06:30 0 30 16:30 22 08: :3
20°CTemperature 16°C 21°C OFF
(S Optioi n 01) i S Status
Enable o sablr di e Service Interval Mode.
(S Optioi n 02 S) i Type
Select eect imposed o thn e heating when service i due.s
(S Optioi n 03 Service Due Date)
Set date when t nex service is due.
(Si Optio 04) Warningn
Select no. of days before service due date.
(S Optioi n 05) Service Due Alarm
Enable or disable th audible e service du alarm.e
(S Optioi n 06 S B st) i oo
Enable or disable th Service e Boos featurt e (5 boosts).
(S Optioi n 07) Password Re tse
Change th 4 digie t PIN. If you forge your Si password, t
please call the Technical Helpline.
Technical Data
The Drayton Digistat thermostat is a universal thermostat with 24
ho
ur, 5-2day
or
7day
program types and up to 8 time/temperature
events per day and can also be use as d a simple room thermostat.
Clock Setting
Press and hold the cog button until User 01 appears,
Press the plus button to Advanced 02, then press O to
enter,
Press O to enter Time settings,
Using the + and - you can adjust the time, then press O
to save,
Press the cog button twice to bring you back to the
home screen.
General Operation
Programmable thermostats do not have “On” and “Off” times like
traditional timers. They offer temperature control both day and
night and you simply select which temperatures you require at
each point in the day.
With the unit in “Auto Mode” (the calendar icon is visible at the
bottom of the screen) the temperature can be changed for a
short time by using the + and – buttons. Changing the
temperature in this way will keep the Digistat set to your
new temperature until the next pre-programmed event (at
which time it will revert to programmed temperature). The
temperature you are setting will flash on the screen. Once
temperature is set, the unit will revert to showing the room
temperature again. The indicator will show on the screen if the
unit is calling for heat.
Programming the Digistat
Your Digistat comes with the following settings
pre-programmed for your convenience and is suitable for those
working out of the house during a typical 9-5 pattern. When the
5-2day program type is selected the pre-set temperatures will be
different Mon-Fri and Sat-Sun, as per
the tables below:
Pre-se Program t 1 (24h, 5-2day weekdays, or 7day):
1Event 2 3 4 (5)* (6) (7) (8)
Time 07:00 09:00 16:00 23:00
20°CTemperature 18°C 21°C OFF
Her y, S i r E c C r s UK L , eb chne de lectri ont ol td de lac res that D igi t B sta 2290
is i plia ec tin com nce with Dir ve 2014/53/E U.
Th de la ate c r ion of c formity may be c d at on onsulte
www.d oncon ls.rayt tro co.uk
* these l To add additiona time peri ll x.ods manua y (ma 8 per le day) p ase
refer to the steps to the right.
Th luetoote B h
®
word d re ma anrk logos a registe demre rad t arks own ed
by Bluetooth S , IG Inc. and any use of such ma s brk y id r El c s Schne e ectri i
un r ic . de l ense Other ra s and t demark tra e s are e d name thos of their
r p ive es ect ow rs.ne
Power supply
230VAC +/-10%, 50Hz
Switch type & rating
16(2)A at 230V / 50Hz
current
SPDT (voltage free contacts)
10mA@24VAC (inductive)
Ambient temperature
Operating: 0°C to +4C
Storage: -20°C to 65°C
Ambient humidity
(non condensing)
20% to 80%, 90% non-condensing
Temperature range
C to 30°C
Rated impulse voltage
4KV
Ball pressure test
75°C
Disconnection means
1B
Automatic action
100,000 cycles
Operating Frequency
2402-2480 MHz
Max RF Power
transmitted
+10dBm
Pollution situation
Degree 2
Protection level
IP30
Wiring
Designed for fixed wiring only, to
comply with IEE wiring regulations
Energy Class
V = 3% using OpenTherm connection
Relevant EC Directives:
2014/53/EU (RED)
2011/65/EU (RoHS)
2012/19/EU (WEEE)
Standards:
EN 60730-1
EN 60730-2-7
EN 60730-2-9
ESTI EN 300 328
ESTI EN 301 489
EN IEC 63000

Produktspecifikationer