Läs gratis den bruksanvisning för Emko ESM-3770-N (2 sidor) i kategorin ej kategoriserat. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 1.5 recensioner. Har du en fråga om Emko ESM-3770-N eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/2

ESM-3770-N 77x35 DIN Size Cooling Controller
Instruction Manual. ENG ESM-3770N 01 V02 02/22
- 4 Digits Display
- NTC Input
-
- 2 Step Fan Output
- Adjustable
- Compressor protection delay
- Having CE mark according to European Norms
ON/OFF temperature control
hysteresis value
- Compressor OK digital input
ESM- 77 x 35 DIN Size3770-N
Digital , ON / OFF Cooling Controller
2
3 41615
13 14
Operating Temperature : -30 to 80 °C
Max. Operating Humidity : 90% Rh (non-condensing)
Altitude : Up to 2000 m.
Forbidden Conditions:
Corrosive atmosphere
Explosive atmosphere
Home applications (The unit is only for industrial applications)
c
1.2 General Specifications
1.Preface
ESM-3770-N series cooling controllers are designed for controlling cooling process. They can
be used in many applications with their easy-use and on / off control form
Some application and application fields which they are used are below:
.
Application Fields
Food
Machine production industries
etc...
Applications
Refrigerators
Air Conditioning
Storages
Freezers
etc...
1.1 Environmental Ratings
ESM-3770-N
Compressor Output
NTC,PTC
Power Supply Input
Sensor Input
Cooling Function
ON/OFF Operation
Standard
Fan Output-1
Fan Output-2
Fan Output Function
ON/OFF Operation
Fan Output Function
ON/OFF Operation
Sensor Input
Digital Input
10 - 30 V Z
A visual inspection of this product for possible damage occurred during shipment is
recommended before installation. It is your responsibility to ensure that qualified mechanical
and electrical technicians install this product.
If there is danger of serious accident resulting from a failure or defect in this unit, power off the
system and separate the electrical connection of the device from the system.
The unit is normally supplied without a power supply switch or a fuse. Use power switch and fuse
as required.
Be sure to use the rated power supply voltage to protect the unit against damage and to prevent
failure.
Keep the power off until all of the wiring is completed so that electric shock and trouble with the
unit can be prevented.
Never attempt to disassemble, modify or repair this unit. Tampering with the unit may results in
malfunction, electric shock or fire.
Do not use the unit in combustible or explosive gaseous atmospheres.
During putting equipment in hole on the metal panel while mechanical installation some metal
burrs can cause injury on hands, you must be careful.
Montage of the product on a system must be done with it’s fixing clamps. Do not do the montage
of the device with inappropriate fixing clamp. Be sure that device will not fall while doing the
montage.
It is your responsibility if this equipment is used in a manner not specified in this instruction
manual.
EMKO Elektronik warrants that the equipment delivered is free from defects in material and
workmanship. This warranty is provided for a period of two years. The warranty period starts
from the delivery date. This warranty is in force if duty and responsibilities which are determined
in warranty document and instruction manual performs by the customer completely.
Repairs should only be performed by trained and specialized personnel. Cut power to the
device before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene etc.). Use of
these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in
ethyl alcohol or water to clean the external plastic case.
1.3 Installation
1.4 Warranty
1.5 Maintenance
1.6 Manufacturer Company
Manufacturer Information:
Emko Elektronik Sanayi ve Ticaret A.Ş.
Repair and maintenance service information:
Emko Elektronik Sanayi ve Ticaret A.Ş.
Bursa Organize Sanayi Bölgesi, (Fethiye OSB Mah.) Ali Osman Sönmez Bulvarı,
2. Sokak, No:3 16215 BURSA/TÜRKİYE
Tel : +90 224 261 19 00
Fax : +90 224 261 19 12
Bursa Organize Sanayi Bölgesi, (Fethiye OSB Mah.) Ali Osman Sönmez Bulvarı,
2. Sokak, No:3 16215 BURSA/TÜRKİYE
Tel : +90 224 261 19 00
Fax : +90 224 261 19 12
2.2 Panel Cut-Out
2. General Description
2.1 Front View and Dimensions of ESM-3770N Cooling Controller
110 mm / 4.33 inch (min)
71 mm / 2.79 inch
29 mm / 1.14 inch
50 mm / 1.97 inch (min)
Front Panel
IP65 protection
NEMA 4X
Panel Surface
(maximum thickness 15 mm / 0.59 inch)
Mounting Clamp
76 mm / 3 inch
6 mm / 0.24 inch
34,5 mm / 1.36 inch
65 mm / 2.56 inch
Maximum 15 mm / 0.59 inch

5. Changing and Saving Temperature Set Value
6.1 Defrost Zamanı Set Değerinin Değiştirilmesi ve Kaydedilmesi
Main Operation Screen
When Increment or Decrement button
pressed SET expression is shown on
display, after relasing the pressed
button ‘’S’’ led will be active and
temperature set value will be displayed.
SET Value Screen
Temperature set value can
be changed with increment
and decrement buttons.
When Compressor button pressed
temperature set value can be saved.
‘’S’’ will be inactive and goes back to
main operation screen.
Main Operation Screen
Temperature set value parameter (Default=18)
Temperature set value
°C.
, can be programmed between temperature set minimum parameter
Value and maximum temperature set value 50
3.2 Device Label and Connection Diagram
3.1 Supply Voltage Input Connection of the Device
Make sure that the power supply voltage is the same
indicated on the instrument.
Switch on the power supply only after that all the electrical
connections have been completed.
Supply voltage range must be determined in order. While
installing the unit, supply voltage range must be controlled
and appropriate supply voltage must be applied to the unit.
c
There is no power supply switch on the device. So a power
supply switch must be added to the supply voltage input.
Power switch must be two poled for seperating phase and
neutral, On/Off condition of power supply switch is very
important in electrical connection.
External fuse that on power supply inputs must be on V
phase connection.
External fuse that on Zpower supply inputs must be on (+)
connection.
c
10-30VZ CONNECTION DIAGRAM
4.Front Panel Definition and Accessing to the Menus
BUTTON DEFINITIONS
1. Increment Button :
** It is used to increase the value in the Set screen and Programming mode.
** In main operation screen; if this button pressed SET
2. Decrement Button :
** It is used to decrease the value in the Set screen and Programming mode.
** In main operation screen; if this button pressed SET
3. Compressor Button:
** in the Set screen and Programming mode, it is used to saving parameter.
** In main operation screen, it is used to activated compressor output.
4. Fan Button:
** In main operation screen; if this button pressed Fan outputs are can be activated with
sequentialy.
** It is used to exit from Set screen and Programming mode to main operation screen without
Saving parameter.
LED DEFINITIONS
5. Compressor Failure led :
** It is active when compressor failure statuses.
6. Compressor output led :
** This led indicates that compressor output is active
7.Fan II led :
**This led indicates that 2. Fan output is active
8.Fan I led :
**This led indicates that 1. Fan output is active
9.Fan 0 led :
** This led indicates that all fan outputs are passive.
10.Set led :
** Indicates that device is in Set value changing mode.
11.Program led :
**Blinks in programming mode .
is shown on the display, after releasing
the pressed button set value is shown on the display and SV led becomes active.
is shown on the display, after releasing
the pressed button set value is shown on the display and SV led becomes active.
5
8
10
9
5 6 9 10
121187
3
c
2.4 Removing from the Panel
1
3
5.1 Programming Mode Parameter List
Hysteresis Parameter for Compressor Output ( Default = 1 )
This parameter can be adjusted between 0 and %50 of device scale.
In ON/OFF control algorithm, temperature
value is tried to keep equal to set value by
opening or closing the last control element.
ON/OFF controlled system, temperature
value oscillates continuously. Temperature
value’s oscillation period or amplitude around
set value changes according to controlled
system. For reducing oscillation period of
temperature value, a threshold zone is formed
below or around set value and this zone is
named hysteresis.
ON
OFF
Temperature
Control
Output
Set
HSt
Time
HSt
Time
Compressor Stop-Start Delay Parameter (Default =0)
When compressor is inactive, this time delay must be expired for activation of the
compressor. It can be adjusted from 0 to 99 seconds.
Decimal Seperator Enabling Parameter ( Default = 0 )
Disable
Enable
c
a
Note-1
5
6
-
+
2
1
2
10...30 V Z2W
When Increment or Decrement
button is pressed for 5 seconds,
“P” led starts to blink.
Main Operation
Press increment button for accessing
to the next parameter, press
decrement button for accessing to
the previous parameter.
5.3 Entering To The Programming Mode, Changing and Saving Parameter
1. Blinking expression on display. Sensor failure. Wrong sensor connection or sensor
break.
5.2 Failure Message on ESM-3770N Device
3. Electrical Wiring Diagram
5
6
7
8
9
Comp.OK
a
2x5 @250V AV
16(8)A
@250V 1HPV
2
3
41
CO P.
M
AF N 1
FAN2
L
N
+
16A T Sigorta
21 3 54 6 7 8 9
P/N : ESM-3770-N
a
a
a
a
a
Compressor OK
10 Z...30 V
10...30 V Z2W
Programming Screen
Press compressor button for accessing to
the parameter value. Press increment button
for accessing to the next parameter, press
decrement button for accessing to the
previous parameter.
Change the value with
increment and decrement
buttons.
Decimal Seperator
Enabling Parameter
Press compressor button for
saving the parameter.
Decimal Seperator
Enabling Parameter
Decimal Seperator
Enabling Parameter
Hysteresis Parameter
2. If temperature value is over the scale high limit, temperature value and displayed on
screen with sequentialy.
6
7
Device Type : Cooling Controller
Housing&Mounting : 76mm x 34.5mm x 71mm plastic housing for panel
Mounting. Panel cut-out is 71x29mm.
Protection Against
Mechanical Impacts : 1Joule (IK06)
Protection Class : Ip65 at front, Ip20 at rear
Weight : Approximately 0.20 Kg.
Environmental Ratings : Standard, indoor at an altitude of less than 2000 meters
with none condensing humidity.
o o o o
Storage / Operating Temperature : -40 C to +80 C / -30 C to +80 C
Storage / Operating Humidity : 90 % max. (None condensing)
Installation : Fixed installation
Overvoltage Category : II.
Pollution Degree : II, office or workplace, none conductive pollution
Operating Conditions : Continuous
Supply Voltage and Power : 10...30
Temperature Sensor Input : NTC ,PTC
NTC Input type : NTC (10 k @25 °C )W
PTC Input type : PTC (1000 @25 °C )W
Accuracy : ± 1 % of full scale for thermoresistance
Sensor Break Protection : Upscale
Sampling Cycle : 3 samples per second
Control Form : ON / OFF
Relay Outputs : A@250 V for Resistive load(Compressor output)16(8) V
(Electrical life : 100.000 switching at full load)
A@250 V for Resistive load (Fan outputs)5 V
Di splay : 14 mm Red 4 digit LED Display
LEDs : S (Green), P (Green), Fan OFF(Yellow),Fan I (Red),Fan II
(Red), Failure Input(Red), Compressor Output (Red)d
V 2WZ
6. Specifications
All order information of ESM-3770-N Cooling Controller are given on the upper table. User may form
appropriate device configuration from information and codes that at the table and convert it to the
ordering codes. Firstly, supply voltage then other specifications must be determined. Please fill the order
code blanks according to your needs.
Please contact us, if your needs are out of the standards.
7. Ordering Information
A BC D E FG HI /
/
U
V W Z/
/
0 2 0 0
1
Relay output ( 16(8) A@250 V at resistive load, 1 NO )V
Compressor Output
E
Power SupplyA
Input Type
BC
Scale(°C)
ESM- 3770-N
-50°C 150°C
12
PTC (Note-1)
Temp. Sensor which is given with ESM-3770-N
V
0
None
3
NTC-M5L20.K1.5 (NTC Sensor, thermoplastic moulded with
1.5 m cable for cooling application)
4
NTC-M6L50.K1.5 (NTC Sensor, stainless steel housing with
1.5 m cable for cooling application)
9
Customer
1 1
8
10...30 V 2WZ
-50°C 100°C
18
NTC (Note-1)
1
PTC-M6L40.K1.5 (PTC Air Probe with 1.5 mt silicon cable)
2
PTCS-M6L30.K1.5.1/8” (PTC Liquid Probe with1.5 mt silicon cable)
(77x35 DIN Size)
1
Relay output ( 5A@250 V at resistive load, 1 NO )V
Fan I Output
FG
1
Relay output ( 5 A@250 V at resistive load, 1 NO )V
Fan II Output
HI
Minimum Temperature Set Value Parameter(Default =10 )
Temperature set value can not be lower than this value.
This parameter value can be adjusted between °C and °C.(-10 ) 50
Note:If no operation is performed in temperature set value changing mode for 3 seconds, device
turns to main operation screen automatically and saved set value.
NOTE : If no operation is performed in programming mode for 20 seconds, device turns to
main operation screen automatically..
+
10..30 VZ
10.. 30. VZ
2W
8 1
3
4
1
2
SET Value Screen
INPUT SCALE
(-50°C,100°C)
2.3 Panel Mounting
Relay Output
Temperature Sensor
Input (NTC or PTC)
Supply Voltage Input
Power Supply Connection
EXTERNAL
FUSE
(1A T)
Supply
Switch
Supply Voltage
11
3. If temperature value is under the scale low limit, temperature value and displayed on
screen with sequentialy.
Your Technology Partner
www.emkoelektronik.com.tr
Thank you very much for your preference to
use Emko Elektronik products, please visit our
web page to download detailed user manual.
1-Before mounting the device in your panel,
make sure that the cut-out is of the right size.
2-Insert the device through the cut-out. If the
mounting clamps are on the unit, put out them
before inserting the unit to the panel.
3- Insert the mounting clamps to the fixing sockets
that located left and right sides of device and make
the unit completely immobile within the panel
1-Pull mounting clamps from left and right fixing
sockets.
2-Pull the unit through the front side of the panel
Before starting to remove the unit from
panel, power off the unit and the related
system.
Note-1 : External fuse is recommended.
Note-2 : Stranded cable cross section: 1,5mm², Solid cable cross-section: 2,5mm²
The stripping length is 7 to 9 mm.
Note-3 : Supply cables must comply with the requirements of IEC 60277 or IEC 60245.
10.. 30. VZ
2W
Compliances
Produktspecifikationer
Varumärke: | Emko |
Kategori: | ej kategoriserat |
Modell: | ESM-3770-N |
Behöver du hjälp?
Om du behöver hjälp med Emko ESM-3770-N ställ en fråga nedan och andra användare kommer att svara dig
ej kategoriserat Emko Manualer
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
ej kategoriserat Manualer
- Nevadent
- Newline
- Blow
- Arkon
- Blodgett
- Akg
- Vemer
- EXSYS
- Brandson
- Tripp Lite
- Celly
- Aspes
- TCL
- Mount-It!
- Xiaomi
Nyaste ej kategoriserat Manualer
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025
21 Juni 2025