Läs gratis den bruksanvisning för Finder 72.C1 (16 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 20 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 10.5 recensioner. Har du en fråga om Finder 72.C1 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/16

说明
72.C1
72.C1.0.000.
72.C1.0.000.
72.C1.0.000.
72.C1.0.000.72.C1.0.000. =
=
=
== H07
H07
H07
H07H07 RN-F
RN-F
RN-F
RN-FRN-F
XX01
XX01
XX01
XX01XX01
IB72C1 - 02/21 Finder S.p.A. con unico socio - 10040 ALMESE (TO) - ITALY
250Vac 10(8)A
T°max: +50°C +122°F
10m / 32,8�
100% MADE IN ITALY


ON
max
OFF
min
ENGLISH
NOTES: DO NOT TAMPER WITH THE FLOAT SWITCH. THE NON RESPECT OF THE FOLLOWING POINTS
WILL AUTOMATICALY CAUSE THE CANCELLATION OF THE WARANTY OF THE PRODUCT
• Before any opera�on on the oat remember to disconnect the power supply from the main power.
• Check that the maximum motor power does not exceed the oat's electrical values.
• In case of cable damage by the nal user or installer, the oat must be replaced.
• Do not make any joint on the cable of the oat switch, as immersion of such joints could cause short circuits or
electrical shocks.
• The maximum slope for proper func�oning is 3° (Fig.1)
USE:
The oat is a level controller that allows the user to bring the water levels at certain heights with a minimum and
maximum range : increase or decrease the distance between the oa�ng units of maximum and minimum(Fig.2) (a)
(b) level unscrewing the screw fastened to the oa�ng unit by means of a screwdriver with cross head and screwing(c)
with force. Make sure that the oa�ng unit is locked securely. The water will act on the oa�ng body when it is
approximately half of this. It's possible to set the opera�on of the oat in automa�c (ON / OFF) or manual (always ON)
via the manual switch on the head of the oat .(d)
TECHNICAL FEATURES:
• Protec�on Grade: IP68
• Features of automa�c ac�on: 1B (micro-disconnec�ons in opera�on)
• Pollu�on Degree: 2
TERMINAL CONNECTIONS:
The upstream circuit must protect the electric wires from the overcurrent. WARNING: lack of protec�on shall null
and void the warrany in the event the oat breaks
The grounding wire is always yellow and green.
• Emptying: (Fig.3) when black and brown wires are used, the circuit opens when oat is down and closes when the
oat is up. Note: the blue/grey wire must be insulated.
• Filling: (Fig.4) when black and blue/grey wires are used, the circuit closes when oat is down and opens when the
oat is up. Note: the brown wire must be insulated.
The tank lls The water reaches the
max level. and it raises
the whole oa�ng body
High level starts the
pump and the tank
drains
The water reaches the
minimum level and the
weight of the oa�ng body
disengages the magnet
Low level stops the
pump
M M
Blue Brown
Black Black
Brown Blue
N N
L L
Yellow/GreenYellow/Green
Fig.3 emptying Fig.4 lling
Produktspecifikationer
Varumärke: | Finder |
Kategori: | Inte kategoriserad |
Modell: | 72.C1 |
Behöver du hjälp?
Om du behöver hjälp med Finder 72.C1 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Finder Manualer
17 September 2024
9 September 2024
3 September 2024
2 September 2024
28 Augusti 2024
25 Augusti 2024
22 Augusti 2024
21 Augusti 2024
20 Augusti 2024
16 Augusti 2024
Inte kategoriserad Manualer
- Jedo
- Omnires
- Polaroid
- BabyDan
- Malouf
- Edesa
- Longvie
- DIEZEL
- Create
- Envertech
- TensCare
- Jonard Tools
- Zomo
- Lehle
- Sightmark
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025