Greisinger GMH 3830 Bruksanvisning


Läs gratis den bruksanvisning för Greisinger GMH 3830 (18 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 6 personer och har ett genomsnittsbetyg på 4.4 stjärnor baserat på 3.5 recensioner. Har du en fråga om Greisinger GMH 3830 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/18
H60.0.11.6C-16
GHM Messtechnik GmbH • Standort Greisinger
Hans-Sachs-Str. 26 • D-93128 Regenstauf
+49 (0) 9402 / 9383-0 +49 (0) 9402 / 9383-33 info@greisinger.de
as of version 2.1 Operating Manual GMH 3830
Resistive material moisture and
temperature measuring Instrument
keep for future reference
WEEE-Reg.-Nr. DE 93889386
GMH 38 Series
Materialfeuchte / material moisture
H60.0.11.6C-16 Operating Manual GMH 3830 Page 2 of 18
_____________________________________________________ _____________________________________________________________________________
Index
1 GENERAL ADVICE .................................................................................................................................................. 3
2 INTENDED USE ........................................................................................................................................................ 3
2.1 SAFETY SIGNS AND SYMBOLS ................................................................................................................................ 3
2.2 SAFETY INSTRUCTIONS ......................................................................................................................................... 3
3 PRODUCT DESCRIPTION ...................................................................................................................................... 4
3.1 SCOPE OF DELIVERY .............................................................................................................................................. 4
3.2 OPERATING AND MAINTENANCE........................................................................................................................... 4
3.3 START UP AND READINESS FOR OPERATION .......................................................................................................... 4
3.4 CONNECTIONS ....................................................................................................................................................... 5
3.5 DISPLAY ELEMENTS .............................................................................................................................................. 5
3.6 PUSHBUTTONS ....................................................................................................................................................... 5
4 DEVICE CONFIGURATION ................................................................................................................................... 6
5 SOME BASICS OF PRECISION MATERIAL MOISTURE MEASURING ...................................................... 7
5.1 MOISTURE CONTENT U AND WET-BASIS MOISTURE CONTENT W ........................................................................ 7
5.2 SPECIAL FEATURES OF THE DEVICE ....................................................................................................................... 7
5.3 AUTO-HOLD FUNCTION ......................................................................................................................................... 7
5.4 AUTOMATIC TEMPERATURE-COMPENSATION ('ATC') ........................................................................................... 7
5.5 MEASURING IN WOOD: MEASURING WITH TWO MEASURING-NEEDLES ............................................................. 8
5.6 MEASURING OTHER MATERIALS .......................................................................................................................... 8
5.6.1 ‘Hard‘ Materials (concrete or similar): Measuring with brush-type probes (GBSL91 or GBSK91) .............. 8
5.6.2 ‘Soft‘ Materials (polystyrene or similar): Measuring with Measuring-rods or -pins (GMS 300/91) ............. 8
5.6.3 Measuring bulk cargo, bales and other special measures ............................................................................. 8
5.7 MEASURING OF MATERIALS, HAVING NO CHARACTERISTIC CURVES STORED ...................................................... 9
6 HINTS FOR SPECIAL FUNCTIONS ..................................................................................................................... 9
6.1 MOISTURE EVALUATION ('WET' - 'MEDIUM' - 'DRY') ..................................................................................... 9
6.2 PRE-SELECTION OF FAVOURITE MATERIALS ('SORT') ............................................................................................ 9
7 OUTPUT ................................................................................................................................................................... 10
7.1 INTERFACE - BASE ADDRESS ('ADR.') ................................................................................................................. 10
7.2 ANALOGUE OUTPUT SCALING WITH DAC.0 AND DAC.1 ................................................................................ 10
8 APPLICATION IN THE GLUED TIMBER CONSTRUCTION ACC. TO DIN 1052-1 (MPA CERTIFIED) ................................. 10
9 FAULT AND SYSTEM MESSAGES ..................................................................................................................... 11
10 INSPECTION OFT THE ACCURACY / ADJUSTMENT SERVICES ......................................................... 11
11 MEASURING PRECISION ................................................................................................................................ 11
12 SPECIFICATION ................................................................................................................................................. 12
13 DISPOSAL NOTES .............................................................................................................................................. 12
14 APPENDIX A: SORTS OF WOOD .................................................................................................................... 13
15 APPENDIX B: ADDITIONAL MATERIALS ................................................................................................... 18
15.1 MEASURING OF BUILDING MATERIALS ............................................................................................................ 18
15.2 MEASURING OF AGRICULTURAL BULK CARGO ................................................................................................ 18
15.3 ESTIMATION OF ADDITIONAL MATERIALS ....................................................................................................... 18
H60.0.11.6C-16 Operating Manual GMH 3830 Page 3 of 18
_____________________________________________________ _____________________________________________________________________________
1 General advice
Read through this document attentively and make yourself familiar to the operation of the device before you
use it. Keep this document in a ready-to-hand way in order to be able to look up in the case of doubt.
2 Intended use
The device is suitable for the measurement of moisture content and temperature.
The measurement is done using appropriate electrodes and cables. The electrodes are connected via a BNC
or thermocouple connector.
The safety instructions of these operating manual must be followed (see below).
The device may be used only under the conditions and for the uses for which it was designed.
The device must be treated carefully and used according to the technical data (do not throw, hit, etc.).
Protect against contamination
2.1 Safety signs and symbols
Warning notices are marked in this manual as shown in table 1:
DANGER
Warning! Symbol warns of impending danger, death, serious
bodily injury or serious property damage if ignored.
Attention! Symbol warns of potential hazards or hazardous
situations that can cause damage on the equipment or the
environment if ignored.
Note! Symbol indicates incidents that have an indirect impact on
the operation or can trigger an unforeseen reaction if ignored.
table 1
2.2 Safety Instructions
This device has been designed and tested in accordance to the safety regulations for electronic devices.
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures
and special safety advises given in this manual will be adhered to when using it.
1. Trouble-free operation and reliability of the device can only be guaranteed if it is not subjected to any
other climatic conditions than those stated under “Specification”.
Transporting the device from a cold to a warm environment condensation may result in a failure of the
function. In such a case make sure the device temperature has adjusted to the ambient temperature
before trying a new start-up.
2. Whenever there may be a risk whatsoever involved in running it, the device has to be
switched off immediately and to be marked accordingly to avoid re-starting. Operator safety
may be a risk if:
- there is visible damage to the device
- the device is not working as specified
- the device has been stored under unsuitable conditions for a longer time
In case of doubt, please return device to manufacturer for repair or maintenance.
3. Do not use this product as safety or emergency stop device or in any other application
where failure of the product could result in personal injury or material damage.
Failure to comply with these instructions could result in death or serious injury and material
damage.
DANGER
DANGER


Produktspecifikationer

Varumärke: Greisinger
Kategori: Inte kategoriserad
Modell: GMH 3830

Behöver du hjälp?

Om du behöver hjälp med Greisinger GMH 3830 ställ en fråga nedan och andra användare kommer att svara dig