Läs gratis den bruksanvisning för Maxwell MX-25109 (12 sidor) i kategorin Multimeter. Guiden har ansetts hjälpsam av 13 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 7 recensioner. Har du en fråga om Maxwell MX-25109 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/12

U Mser anUal
Használati Utasítás
ManUal de Utilizare
Užívateľská prírUčka
DIGITAL MULTIMETER
DIGITÁLIS MULTIMÉTER
MULTIMETRU DIGITAL
DIGITÁLNY MULTIMETER
Product code / Termékkód / Cod produs / Kód produkta:
25109

EN
User Manual
G eneral cHaracteristics
This 3½ digit multimeter is perfect for
measuring DC and AC voltage, DC current,
resistance and diode. It also has a continuity
function and can be used as a logical tester. It is
ideal for work and home use as well.
specification
1. Displaying: 22 mm digit height LCD display
2. Max. Indication: 1999 (31/2) auto polarity
indication
3. Sampling rate: approx. 3 times/ sec
4. Over Range Indication: MSD displays "1"
5. Low Battery Indication: " " symbol displays.
6. Operation Environment: (0~40)°C, relative
humidity <80%
7. Power: 9V battery (NEDA1604/6F22 or
equivalent)
8. Measurement: 145×85×30mm
(Length×Width×Height)
9. Weight: Approx. 170g (including a 9V battery)
t He front panel
1. Display
3½ digits, 7 segments, large LCD (27 × 53 mm)
2. Function and range switch
This switch selects the functions and the desired
range. It also turns the device on. To prolong
battery life set it to OFF when you are not using
the device.
3. “10A” banana (wire) connector
Connect the red (positive) measuring wire into
this connector to measure 10A current.
4. “VΩmA” banana connector
Connect the red measuring wire into this
connector to measure every kind of voltage,
resistance and current (except for 10A)
5. “COM” banana connector
Connect the black (negative) measuring wire
here.
t ecHnical data
DC voltage
Range Resolution Accuracy
200mV 100μV
±0.5% +4D
2V 1mV
20V 10mV
200V 100mV
600V 1V ±1.0% +5D
Overload protection: 600V DC
Input impedance: 1MΩ
AC voltage
Range Resolution Accuracy
200V 100mV ±1.2% +10D
600V 1V
Frequency range: 40Hz ~ 200Hz
Overload protection: 600V RMS
Input impedance: 1MΩ
1.
2.
3. 4.
5.
R
MP 25109
20MΩ
200mV
2V
20V
200V
200V
200µA
20µA
600V
600V
200kΩ
200Ω
10A
200mA
20mA
10sec MAX
FUSED
10A
10A
A
v
v~
COM
mAVΩ
MAX 600V
FUSED
CAT III
200mA
2mA
20kΩ
2kΩ
OFF
Ω
+
-

User Manual
EN
Continuity test with audio signal
Range Description
A built-in beeper
signals if the
resistance is below
70±20Ω
Overload protection: 15 seconds maximum
250V DC/AC peak value
DC current
Range Resolution Accuracy
20uA 0.01μA
±1.5% +3D
200uA 0.1μA
2mA 1μA
20mA 10μA
200mA 100μA
10A 10mA ±2% +5D
Overload protection: 200mA/250V fuse and
10A/250V fuse
Max. input current: 10A (max. 6 sec.)
Resistance
Range Resolution Accuracy
200Ω 0.1Ω ±0.8% +5D
2kΩ 1Ω
±0.8% +3D20KΩ 10Ω
200KΩ 100Ω
20MΩ 10kΩ ±1.0% +15D
Max. open circuit voltage: 3.0V
Overload protection: 15 seconds maximum
250V RMS
operation
WARNING
To avoid electric shock and damage to the
device do not measure voltage exceeding 300V!
Always verify the intactness and insulation of
the measuring wires, connectors and other units
before measuring!
DC and AC voltage measuring
connector and the black one to the “COM”
connector.
voltage position. If the voltage is unknown,
set the switch to the highest available range,
connect the wires to the device and the circuit
and reduce the range until the value shown is
correct.
DC current measuring
connector and the black one to the “COM”
connector. (For measuring current between
200mA and 10A connect the red wire into the
“10A” connector).
position
serially.
use only. The measuring wire should only be
connected to the circuit for the maximum of 6
seconds and allow a few seconds in between
measurements.
Resistance measuring
connector and the black one to the “COM”
connector.
position.
Diode measuring
connector and the black one to the “COM”
connector.
” position.
of the measured diode and the black one to the
cathode.
the screen in mV-s. If the diode is closing, the
screen shows “1”.
Produktspecifikationer
Varumärke: | Maxwell |
Kategori: | Multimeter |
Modell: | MX-25109 |
Färg på produkten: | Black, Grey |
Vikt: | 4500 g |
Bredd: | 240 mm |
Djup: | 305 mm |
Höjd: | 245 mm |
På / Av knapp: | Ja |
Vattentankens kapacitet: | 1.1 l |
Mjukt grepp: | Ja |
Kontinuerlig ånga version: | 85 g/min |
Yttersulans material/beläggning: | Aluminium zoolplaat |
Maximalt ångtryck: | 3 bar |
Järnets kraft: | 750 W |
Ånga redo ljus: | Ja |
Pannkraft: | 1000 W |
Behöver du hjälp?
Om du behöver hjälp med Maxwell MX-25109 ställ en fråga nedan och andra användare kommer att svara dig
Multimeter Maxwell Manualer
6 Oktober 2024
4 September 2024
31 Augusti 2024
18 Augusti 2024
12 Augusti 2024
11 Augusti 2024
8 Augusti 2024
3 Augusti 2024
2 Augusti 2024
1 Augusti 2024
Multimeter Manualer
- Rigol
- Proline
- Caltek
- Tacklife
- Multimetrix
- Jung
- Skandia
- Yato
- Schneider
- Hager
- Digitus
- Kurth Electronic
- Biltema
- Metrel
- Owon
Nyaste Multimeter Manualer
17 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025