Läs gratis den bruksanvisning för Rane FPM 42 (4 sidor) i kategorin blandningskonsoler. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 5.0 stjärnor baserat på 1.5 recensioner. Har du en fråga om Rane FPM 42 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/4
OPERATING / SERVICE MANUAL
FPM42
Set the GAIN switches on the front of the module so the desired level is obtainable without il-
luminating the red OL (overload) LEDs on the channels. Set the A and B LEVEL controls on
each input for the desired level. Set the AUX level control as needed.
The MASTER A/B output level controls affect only the signal level at the direct outputs of the
unit. They have no affect on the main output added to the BUS OUT.
NEVER CONNECT ANYTHING EXCEPT AN APPROVED RANE POWER SUPPLY TO
THE RED THING THAT LOOKS LIKE A TELEPHONE JACK ON THE REAR OF THE
UNIT. This is an AC input and requires special attention if you do not have a power supply EX-
ACTLY like the one originally packed with your unit. See the full explanation of the power supply
requirements elsewhere in this manual.
QUICK START
This section is for those ready to just do it. It familiarizes you enough with the FPM 42 to allow
operation without wading through the rest of the text. Please read at least this section to ensure
reasonable operation of the unit.
Begin with the inputs. They are connected to the 3-pin (XLR) jacks on the rear. Follow the
standard convention of pin 2 hot, pin 3 not and do it.
Set the internal PRE/POST Aux assign switches as necessary. The A and B MASTER OUT-
PUTS may be used balanced or unbalanced. If AUX outputs are needed change the internal
jumper blocks as necessary, or take them from the BUS OUT connector.
Connect the Flex bus cables to the appropriate source for the FLEX BUS IN and the next unit
for FLEX BUS OUT.
SYSTEM CONNECTION
When connecting the FPM 42 to other components in your system for the first time, LEAVE
THE POWER SUPPLY FOR LAST. This gives you a chance to make mistakes and correct
them without damage to your fragile speakers, ears and nerves.
INPUTS. The four channel inputs on the FPM 42 are active balanced. Use only shielded cable
for inputs and outputs. This wire should always be two-conductor plus shield, even for un-
balanced operation. As with all Rane products, pin 2 is used for “hot” or “+” signal polarity, pin
3 is “return” or “–” and pin 1 is signal ground. For unbalanced inputs, drive pin 2 hot and pin 1
signal ground. It is not necessary to short pin 3 to ground. (It will not hurt anything either.) If the
input is coming from another piece of equipment in the signal path, connect the shield only at the
receiving end to help prevent ground induced hum. If a microphone is being connected to the
unit, the shield may be connected to the case of the mic as well as to the ground terminal on the
unit. (Phantom power applications require this.)
OUTPUTS. The FPM 42’s Master A and B outputs are balanced as shipped and connected to
the two l/4" TRS jacks. The Aux A/B outputs appear only on the BUS OUT jacks. You may
reprogram this arrangement by changing internal jumpers. The new configuration puts an un-
balanced Master A/B signal on one of the l/4" outputs, and an unbalanced Aux A/B signal on the
other.
FLEX BUS IN. The 7-pin DIN bus connectors are used primarily with other Flex modules.
These are not MIDI connectors. Use only the supplied DIN cable. If for some reason there is not
a cable in the FPM 42 box, please contact Rane for a replacement. If you are in a bind, a 5-pin
DIN may be used instead of a 7-pin. The two outside pins (6 & 7) are spares on the FPM 42 and
have been included for possible future compatibility reasons. This input is to be used when com-
bining the FPM 42 with the bus outputs of other modules such as another FPM 42, an FMI 14,
etc. Bringing in bus signals allows the FPM 42’s mix to add to the bus and be routed on to the
next unit, and so on.
FLEX BUS OUT. The FLEX BUS OUT of the FPM 42 connects to other Flex mixer modules to
complete a system. The receiving device may be any Flex module with a FLEX BUS IN. See the
Flex Users Guide for additional details.
FRONT PANEL DESCRIPTION
1. INPUT LEVEL CONTROLS. These concentric level controls set the level of each
input to be routed to the Master A/B outputs and buses. The inner knob controls the level
to be sent to A, the outer knob controls the signal applied to B. Rotating the knobs
together creates a “pan centered” effect. Leaving one off and increasing the other emu-
lates a full pan to one side.
2. GAIN SELECT SWITCH. These switches set the maximum gain of the input stages in
each of the four input sections. The 60 dB mode is normally used for most microphones.
The 40 dB mode would be used for high level microphones or very weak line level inputs.
The 20 dB mode is suitable for line level inputs.
3. AUX SEND LEVEL CONTROL. There is only one of these for both the AUX A and
B sends. It controls the amount of channel input fed equally to the optional A and B Aux
outputs. This control’s range is from Off to +10 dB. The Aux source is selected from
either pre- or post fade via internally located switches.
4. OVERLOAD INDICATOR This red LED comes on anytime the input amplifier ex-
ceeds a level of 4 dB below clipping.
5. MASTER A & B LEVEL CONTROLS. These concentric knobs set the signal output
level of the Master A output (inner knob) and the Master B output (outer knob). Their
range is from Off to +10 dB.
6. POWER INDICATOR. Indicates power, as indicated.


Produktspecifikationer

Varumärke: Rane
Kategori: blandningskonsoler
Modell: FPM 42

Behöver du hjälp?

Om du behöver hjälp med Rane FPM 42 ställ en fråga nedan och andra användare kommer att svara dig




blandningskonsoler Rane Manualer

Rane

Rane RPE 228 Bruksanvisning

9 September 2025
Rane

Rane MQ 302S Bruksanvisning

9 September 2025
Rane

Rane PE 15 Bruksanvisning

9 September 2025
Rane

Rane GE 14 Bruksanvisning

9 September 2025
Rane

Rane ME 30B Bruksanvisning

9 September 2025
Rane

Rane GE 130 Bruksanvisning

9 September 2025
Rane

Rane MM 8z Bruksanvisning

9 September 2025
Rane

Rane MQ 15/30 Bruksanvisning

9 September 2025
Rane

Rane GQ 15 Bruksanvisning

9 September 2025
Rane

Rane NM 48 Bruksanvisning

9 September 2025

blandningskonsoler Manualer

Nyaste blandningskonsoler Manualer