Läs gratis den bruksanvisning för SEADA G44-HDMI (1 sidor) i kategorin Processor. Guiden har ansetts hjälpsam av 28 personer och har ett genomsnittsbetyg på 3.8 stjärnor baserat på 14.5 recensioner. Har du en fråga om SEADA G44-HDMI eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/1
SD-EN-012 V01
G44-HDMI Quick Start Manual
Note
1. Do not fix the device to any surface which is a heat source to avoid over heating
2. Do not cover the surface or ventilation grills of the device to avoid over heating
1. Verify the package contents
Please verify the package contents against the List Below
1. G44-HDMI Controller
x1
5. Network Cable
x1
2. Power Cable
x1
6. Remote Control
x1
3. Quick Start Manual
x1
7. 5-pin Phoenix Connector
x4
4. Ground Wire
x1
8. 3-pin Phoenix Connector
X4
2. Set up the G44-HDMI
I. Connect the power cable to the unit and power it up
II. Connect the outputs to the screens of the video wall
III. Connect all the video sources to the inputs of the devices
Note: G44H remembers the settings used on the device before powering off. The default setting for the new
unit is 2x2 video wall with input 1 across the 4 screens. All outputs are set at resolution of 1920 x 1080@60.
3. Run the software on control PC
Users can run the G44H.exe software directly without installation. Software can be downloaded from the
SEADA website (https://seada.co.uk/downloads). Double click the G44H software to get started.
4. Connect through Serial Port
Connect the G44-HDMI with a serial cable to the control PC (cable not included in the package)
If the software was connected via UART (RS232) last time,
software will connect to the G44-HDMI automatically via
RS232. If it was used at Network last time, a ‘Network
Timeout’ error message will be shown on screen and users need to set up as below for RS232 connection in
the software
Choose ‘UART’ instead of ‘Network
Select the COM port from the Port dropdown menu
Press ‘Disconnected button to connect
5. Connect through Network
The default IP address for G44-HDMI controller is 192.168.0.247, Users need to change the IP address of the
control PC to static IP address and the same network segment as the G44-HDMI at TCP/IPv4 in Ethernet
Properties
IP address: any address between 192.168.0.2 and 192.168.0.254 except the address which has been taken
by the G44-HDMI
Subnet mask: 255.255.255.0, Default Gateway: 192.168.0.1
Connect the G44-HDMI with a CAT cable to the control PC (cable included in the package)