Texas Instruments ADS131A04 Bruksanvisning
Texas Instruments ej kategoriserat ADS131A04
Läs gratis den bruksanvisning för Texas Instruments ADS131A04 (95 sidor) i kategorin ej kategoriserat. Guiden har ansetts hjälpsam av 12 personer. Har du en fråga om Texas Instruments ADS131A04 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/95

SCLK
DOUT
DIN
Control and
Serial Interface
GND
AVSS
DRDY
AVDD
VNCP
XTAL1/CLKIN
CS
Negative
Charge
Pump
Voltage
Reference
ADS131A04 Only
Reference
Mux
REFEXT
IOVDD
CLK/XTAL
XTAL2
M[2:0]
RESET
DONE
'6 ADC
'6 ADC
'6 ADC
'6 ADC
AIN4N
AIN4P
AIN3N
AIN3P
AIN2N
AIN2P
AIN1N
AIN1P
REFNREFP
Out-of-Range
Detect
Data Integrity
Watchdog
Timer
Product
Folder
Order
Now
Technical
Documents
Tools &
Software
Support &
Community
AnIMPORTANTNOTICEattheendofthisdatasheetaddressesavailability,warranty,changes,useinsafety-criticalapplications,
intellectualpropertymattersandotherimportantdisclaimers.PRODUCTIONDATA.
ADS131A02
,
ADS131A04
SBAS590E–MARCH2016–REVISEDJUNE2020
ADS131A0x2-or4-Channel,24-Bit,128-kSPS,Simultaneous-Sampling,Delta-SigmaADC
1
1Features
1
•2or4simultaneous-samplingdifferentialinputs
•Dataratesupto128kSPS
•Highperformance:
–Single-channelaccuracy:betterthan0.1%at
10,000:1dynamicrange
–Effectiveresolution:20.6bitsat8kSPS
–THD:–100dBat50Hzand60Hz
•Integratednegativechargepumpallowsabsolute
inputvoltagesbelowground
•Flexibleanalogpower-supplyoperation:
–Usingnegativechargepump:3.0Vto3.45V
–Unipolarsupply:3.3Vto5.5V
–Bipolarsupply:±2.5V
•Digitalsupply:1.65Vto3.6V
•Low-driftinternalvoltagereference:6ppm/°C
•ADCselfchecks
•Cyclicredundancycheck(CRC)andhamming
codeerrorcorrectiononcommunications
•MultipleSPIdatainterfacemodes:
–Asynchronousinterrupt
–Synchronousmasterandslave
•Package:32-pinTQFP
•Operatingtemperaturerange:
–40°Cto+125°C
2Applications
•Electricitymeters:commercialandresidential
•Circuitbreakers
•Batterytestequipment
•Batterymanagementsystems
•Dataacquisitionsystems
3Description
TheADS131A02andADS131A04devicesaretwo-
andfour-channel,simultaneous-sampling,24-bit,
delta-sigma(ΔΣ),analog-to-digitalconverters(ADCs).
Thewidedynamicrange,withscalabledataratesup
to128kSPS,andinternalfaultmonitorsmakethe
ADS131A02orADS131A04agoodchoicewhen
designingforenergymonitoring,gridprotection,and
controlapplications.TheADCinputscanbe
independentlyanddirectlyinterfacedtoaresistor-
dividernetwork,acurrenttransformer,oraRogowski
coiltomeasurevoltageorcurrent.Flexiblepower-
supplyoptions,includinganinternalnegativecharge
pump,areavailabletomaximizetheeffective
resolutionforhighdynamicrangeapplications.
Asynchronousandsynchronousmasterandslave
interfaceoptionsareavailable,providingADC
configurationflexibilitywhenchainingmultipledevices
inasinglesystem.Severalinterfacechecks,ADC
startupchecks,anddataintegritycheckscanbe
enabledontheinterfacetoreporterrorsintheADC
andduringdatatransfer.
Thecompleteanalogfront-end(AFE)solutionsare
packagedina32-pinTQFPpackageandare
specifiedovertheindustrialtemperaturerangeof
–40°Cto+125°C.
DeviceInformation
(1)
PARTNUMBERPACKAGEBODYSIZE(NOM)
ADS131A0xTQFP(32)5.00mm×5.00mm
(1)Forallavailablepackages,seetheorderableaddendumat
theendofthedatasheet.
SimplifiedBlockDiagram
Produktspecifikationer
| Varumärke: | Texas Instruments |
| Kategori: | ej kategoriserat |
| Modell: | ADS131A04 |
Behöver du hjälp?
Om du behöver hjälp med Texas Instruments ADS131A04 ställ en fråga nedan och andra användare kommer att svara dig
ej kategoriserat Texas Instruments Manualer
3 April 2026
31 Mars 2026
5 Mars 2026
5 Mars 2026
5 Mars 2026
5 Mars 2026
5 Mars 2026
5 Mars 2026
5 Mars 2026
5 Mars 2026
ej kategoriserat Manualer
Nyaste ej kategoriserat Manualer
3 April 2026
3 April 2026
3 April 2026
3 April 2026
3 April 2026
3 April 2026
3 April 2026
3 April 2026
3 April 2026