Ventus W210 Bruksanvisning
Ventus
Väderstation
W210
Läs gratis den bruksanvisning för Ventus W210 (10 sidor) i kategorin Väderstation. Guiden har ansetts hjälpsam av 40 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 20.5 recensioner. Har du en fråga om Ventus W210 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/10

Big Digit Multi-Channel Display Wireless Thermo-Hygrometer
with Self-Calibration & Auto-Night Light
Model: C2065A
User Manual
Thank you for purchasing this delicate Big Digit Multi-Channel Display
Wireless Thermo-Hygrometer with Self-Calibration & Auto-Night Light.
Utmost care has gone into the design and manufacture of the clock.
This manual is used for EU version. Please read the instructions
carefully according to the version you purchased and keep the manual
well for future reference.
OVERVIEW
MAIN UNIT
1. [ LIGHT ] key
- In normal mode, press once for 5-second backlight.
- When using the [ LIGHT ] key to activate the backlight, operating
other function keys will re-time the 5-second backlight.
- Press once to stop temperature and humidity alert sound.
2. [ CHANNEL / + ] key
- In temperature and humidity calibration mode, press to increase
the value.
- In normal mode, press to switch between INDOOR, Channel
1,2,3,4,5,6,7 and 8.
- In normal mode, press and hold for 2 seconds to enter auto-
cycle mode that Channel 4~8 and INDOOR’s temperature
and humidity readings will alternately be displayed at 4 second
intervals. The “
” icon will display during auto-cycle mode.
- During auto-cycle mode, press once to return to normal mode.
3. [ MODE / ALERT ] key
- In temperature and humidity calibration mode, press once to
switch between setting options.
- In temperature and humidity calibration mode, press and hold for
- In normal mode, press and hold for 2 seconds to enter
temperature and humidity alert setting mode.
- In temperature and humidity alert setting mode, press once to
switch between setting options. Press and hold for 2 seconds to
4. [ MEM / - ] key
- In temperature and humidity calibration mode, press to decrease
the value.
- In normal mode, press once to check maximum and minimum
temperature and humidity records. Press again to return to
normal mode.
- When the maximum and minimum temperature and humidity
records are displayed, press and hold for 2 seconds to erase the
current records.
5. [ TUNE ] key
- In normal mode, press and hold for 2 seconds to enter
temperature and humidity calibration mode.
- In temperature and humidity calibration mode, press and hold for
2 seconds to return to normal mode.
6. [ ALERT ON / OFF]
- In temperature and humidity alert setting mode, press to turn on/
- Press once to stop alert sound.
7. Auto night-light slide switch
- Slide to [ ON ] position to activate night-light function. When it
is ON, the backlight will automatically turn on in dim and dark
environment detected by the light sensor. The brightness of night-
light is weaker than normal backlight.
- Slide to [ OFF ]
8. [ °C / °F ] key
- Press to switch between °C/°F.
9. [ SENSOR ] key
- In normal mode, press once to manually enter current channel’s
receiving mode. The unit will receive active sensor’s signals for 5
minutes and erase the current channel’s records.
10. [ RESET ] key
- Press once to perform overall function and display option resets.
- In case of malfunction, the unit may be required to reset.
WIRELESS HYGRO-THERMO SENSOR
2
3
4
5
1
1. Transmission status LED
- Flash when the sensor is
transmitting.
2. Wall mounting holder
3. [ CHANNEL ] slide switch
- Assign the sensor to Channel
1,2,3,4,5,6,7 or 8.
4. [ RESET ] key
- Press to restart the sensor.
5. Battery compartment
- Accommodates 2 x AA size
batteries.
1
2
3
4
5
6
7
8
9
10
WIRELESS SENSOR
1. Remove the battery door of the sensor.
2. Insert 2 x AA size batteries into the battery compartment. Make
sure you insert them the right way according to the polarity
information marked on the battery compartment.
3. Close the battery door.
Note:
- Once the channel is assigned to one sensor, you can only
change it by removing the batteries or resetting the unit.
- Avoid placing the sensor in direct sunlight, rain or snow.
MAIN UNIT
1. Remove the battery door of the main unit.
2. Install 4 new AA size batteries according to the polarity
information marked on the battery compartment and then press
[ RESET ] key by using a metal wire to reset the unit.
3. Close the battery door.
4. Once the batteries are installed, all the segments of the LCD will
be shown.
Note:
To avoid the wireless sensor and main unit pairing failure, please
SRZHUXSWKHVHQVRUV¿UVWDQGWKHQSUHVV[ RESET ] key on the
main unit (no need on sensors).
INDOOR TEMPERATURE AND HUMIDITY FUNCTION
1. Press [ °C / °F ] key to switch between °C/°F. Decimal point is
HႇHFWLYHIRUERWKVHWWLQJV
2. When the temperature is below -40°C or above 70°C, “Lo” or “Hi”
will be displayed respectively. The humidity display will show “--”.
Temperature below -40°C Temperature above 70°C
3. When the humidity is below 1% or above 99%, “Lo” or “Hi” will be
indicated respectively.
Humidity below 1% Humidity above 99%
COMFORT INDICATION
The comfort indication is a pictorial indication based on indoor air
temperature and humidity in an attempt to determine comfort level.
Too cold Comfortable Too hot
Note:
- Comfort indication can vary under the same temperature,
depending on the humidity.
- There is no comfort indication when temperature is below 0°C
(32°F) or over 60°C (140°F).
TEMPERATURE & HUMIDITY TREND
The temperature & humidity trend indicator shows the trends of
changes in the forthcoming few minutes. Arrows indicate a rising,
steady or falling trend.
Arrow indicator
Trend Rising Steady Falling
TEMPERATURE AND HUMIDITY CALIBRATION
1. In normal mode, press and hold [ TUNE ] key for 2 seconds to
enter temperature and humidity calibration mode in which the
current outdoor channel or “IN´LFRQZLOOÀDVK3UHVV[ CHANNEL
/ + ] or [ MEM / - ] key to choose for INDOOR or GLႇHUHQW
CHANNEL.
2. Press [ MODE / ALERT ] key again to switch between channel,
temperature and humidity. Press [ CHANNEL / + ] or [ MEM / - ]
key to adjust the value.
Choose Channel
3. :KHQ¿QLVKHGSUHVV[ TUNE ] key for 2 seconds or leave the unit
for 60 seconds to return to normal mode.
4. Pressing [ MODE / ALERT ] key for 2 seconds during
temperature and humidity calibration mode will reset the value to
the actual or uncalibrated measurement.
5. Reset the temperature and humidity values for each channel
individually. There is no batch reset.
6. &DOLEUDWLRQPRGHVHTXHQFHFKDQQHOĺWHPSHUDWXUHĺKXPLGLW\
7. In temperature calibration mode, press [ CHANNEL / + ] or
[ MEM / - ] key to modify 0.1 °C or °F of the value. Long press to
quick-adjust the value.
Temperature calibration mode
8. In humidity calibration mode, press [ CHANNEL / + ] or [ MEM
/ - ] key to modify 1% of the value. Long press to quick-adjust the
value.
Humidity calibration mode
9. If the current reading of the selected channel displays the
ÀDVKLQJ³--”, “Hi” or “Lo”, it will be impossible to adjust. Pressing
[ CHANNEL / + ] or [ MEM / - ] key will not change the value.
10. If re-enter temperature and humidity calibration mode, the
adjusted value will reset to the original value.
11. The comfort indication is based on calibrated temperature and
humidity values to calculate.
MAX/MIN TEMPERATURE AND HUMIDITY RECORD
The unit preserves the MAX/MIN temperature and humidity records
since the last manual reset.
1. In normal mode, press [ MEM / - ] key once to show the current
maximum temperature and humidity values; press again to show
the minimum values; press the third time to return to normal
mode.
2. When the MAX/MIN records are shown, the display will return to
normal mode after leaving the unit for 5 seconds.
MAX records MIN records
Produktspecifikationer
| Varumärke: | Ventus |
| Kategori: | Väderstation |
| Modell: | W210 |
Behöver du hjälp?
Om du behöver hjälp med Ventus W210 ställ en fråga nedan och andra användare kommer att svara dig
Väderstation Ventus Manualer
18 Oktober 2024
20 September 2024
20 September 2024
20 September 2024
20 September 2024
7 September 2024
6 September 2024
3 September 2024
2 September 2024
30 Augusti 2024
Väderstation Manualer
- Greenure
- Beurer
- Fluke
- Taylor
- Nor-tec
- Avidsen
- Sempre
- Ade
- Optex
- Levenhuk
- Konig
- PCE Instruments
- Auriol
- Blaupunkt
- ECG
Nyaste Väderstation Manualer
2 April 2025
27 Mars 2025
27 Mars 2025
5 Mars 2025
27 Februari 2025
15 Februari 2025
5 Februari 2025
27 Januari 2025
27 Januari 2025
12 Januari 2025