Vimar 01974 Bruksanvisning
                    Vimar
                    
                    Inte kategoriserad
                    
                    01974
                
                                
    Läs gratis den bruksanvisning för Vimar 01974 (2 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 29 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 15 recensioner. Har du en fråga om Vimar 01974 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
                        Sida 1/2
                    
                    
                    
Viale Vicenza, 14
36063 Marostica VI - Italy
www.vimar.com
49400841A0  03  1910
01974
Actuator  with  4  change-over  relay  outputs  16  A  120-230  V~, 
programmable  with  control  function  for  lights,  roller  shutters  with 
slat orientation, fan-coil, push-buttons for local control, By-me home 
automation system, installation on DIN rails (60715 TH35), occupies 4 
modules size 17.5 mm. Version for MARINE applications.
FEATURES.
• Rated supply voltage: BUS 29 V.
• Typical current draw: 20 mA.
• 4  relay  outputs  (N/C,  C,  N/O)  for  lights  control;  relays  1+2  and  3+4  can  be 
grouped for roller shutter control.
• Can be used for the fan-coil function.
• Push-buttons for manual relay control.
• Push-button to enable/disable the manual controls.
• LED for relay status.
• LED and configuration button.
• Protection class: IP20.
• Operating temperature: -5 °C to +45°C (indoor use).
• Overall dimensions: 4 modules of 17.5mm.
• Compatible with By-me 21509 control units and EasyTool Professional.
CONTROLLABLE LOADS.
•   Relay output (controllable loads at 120 - 230 V~, N/O contacts):
- resistive loads   : 16 A (20,000 cycles); 
-  incandescent lamps   : 8 A (20,000 cycles);
-  fluorescent lamps, with energy saving and LED  : 0.5 A (20,000 cycles);
-  electronic transform  : 6 A (20,000 cycles);ers 
• Relay output (controllable loads at 120 - 230 V~, N/O and N/C contacts): 
-  cos ø 0.6 motors: 3.5 A (100,000 cycles). 
MANUAL MANAGEMENT.
Pressing  the    button  enables  using  the  buttons  to  actuate  the  relays.  All 
messages from the bus are ignored.
• If the device is reset each relay is controlled with its own button.
• If the device is configured, the relays configured individually are controlled by the 
relevant  button  while  the  relays  configured  in  pairs  for  roller  shutter  control  are 
controlled by the buttons for the UP function ( ) and DOWN function ( ) with a  
reversal time in the passage from UP to DOWN; whereas if they are configured for 
fan-coil control, relays 1,2,3 are controlled alternately.
In normal operation, pressing the relay actuation buttons is ignored.
CONFIGURATION  WITH  BY-ME  CONTROL  UNIT  OR  EASYTOOL 
PROFESSIONAL. 
For full  details  see the  relevant  Installer  manuals  that  can  be downloaded 
from the website www.vimar.com.
INSTALLATION RULES.
• Installation  should be carried out  by  qualified personnel in compliance  with  the 
current regulations regarding the installation of electrical equipment in the country 
where the products are installed.
• The 4 relay outputs are separated from each other by functional insulation at 250 
V~ and not by double insulation; because of this, for example, do not connect a 
SELV circuit to an output that is adjacent to another one that is connected to the 
230 V~ power supply.
•  The  relay  output  power  circuits  must  be  protected  against  overcurrents  by 
installing  devices  or  fuses  with  a  rated  breaking  capacity  of  1500  A  or  type-C 
circuit breakers, with rated current not exceeding 16 A. 
STANDARD CONFORMITY.
LV directive. EMC directive. Standards EN 60669-2-5, EN 50491.
For MARINE use, this device has been submitted to the following tests:
IEC 60068-2-52 - Test Kb: Salt mist, cyclic (sodium, chloride solution),
IEC 60068-2-6 - Test Fc: Vibration (sinusoidal)
This device complies with part 15 of the   Rules (with the limits for a Class BFCC
digital device). 
FRONT VIEW.
OUT 1 OUT 2 OUT 3
CNONC CNONC CNONC
BUSOUT 4
C NO NC
01974
SWITCH
ACTUATOR
OUT 2
OUT 1
OUT 3
OUT 4
CONF.
By-me
16A
μ
120-230V~50/60Hz
3,5A
M
A
C
NO
NC
B
C
D
E
F
NC
NO
C
C C
NO
NC
NO
NC
BUS line 
Relay 1 Relay 2 Relay 3
Relay 4
A: LED and button to actuate relay 1
B: LED and button to actuate relay 2 
C: LED and button to actuate relay 3
D: LED and button to actuate relay 4
E: LED and configuration button 
F: Manual mode push-button
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept 
any  interference  received,  including  interference  that  may  cause  undesiderable 
operation.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces 
of lead. 
WEEE - Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must  not be 
included with other general waste at the end of its working life. The user must take the worn product to a sorted 
waste center, or return it to the retailer when purchasing a new one. Products for disposal can be consigned free 
of charge (without any new purchase obligation) to retailers with a sales area of at least 400 m 2, if they measure 
less than 25 cm. An efficient sorted waste collection for the environmentally friendly disposal of the used device, 
or its subsequent recycling, helps avoid the potential negative effects on the environment and people’s health, 
and encourages the re-use and/or recycling of the construction materials.
Produktspecifikationer
| Varumärke: | Vimar | 
| Kategori: | Inte kategoriserad | 
| Modell: | 01974 | 
Behöver du hjälp?
Om du behöver hjälp med Vimar 01974 ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad Vimar Manualer
                        
                         7 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         3 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            
                        
                         2 April 2025
                        
                    
                                                            Inte kategoriserad Manualer
- XS Power
- AVTech
- Datacard
- I-Tec
- Conceptronic
- Seenergy
- Telstra
- Audient
- Doepfer
- Stirling
- Varad
- Advantix
- Momo Design
- Grace Design
- Sightron
Nyaste Inte kategoriserad Manualer
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025
                        
                    
                                                            
                        
                         9 April 2025