Vimar 03989 Bruksanvisning
Läs gratis den bruksanvisning för Vimar 03989 (6 sidor) i kategorin Termostat. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 2 recensioner. Har du en fråga om Vimar 03989 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/6

Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
03989 01 2505
03989 - IoT connected thermostatic head
VIEW WIRELESS SMART HOME
The thermostatic head, fitted directly on the radiator, regulates the room temperature by con-
trolling the flow of hot water circulating in the radiators of a heating system. Thanks to Bluetooth
technology connectivity, it integrates into the View Wireless system and can be controlled manual-
ly locally, by an IoT thermostat (if configured in association), or remotely via the View App or voice
assistants. The IoT connected heads replace existing thermostatic heads and are compatible
with most valves through the use of various adapters (see the VALVE COMPATIBILITY TABLE).
Download the View Wireless App from the stores onto the tablet/smartphone you
will be using for configuration.
When the device is powered for the rst conguration, we recommend you search for any
new rmware and perform the update.
You will also need:
Gateway art. 30807.x-20597-19597-14597
View App
for management via smartphone/tablet
Amazon Alexa, Google Assistant, Siri (Homekit) voice assistants for possible voice
operation
GENERAL SYSTEM CONFIGURATION
1. Create your Installer account on MyVIMAR (on-line).
2. Wire all the devices in the system (2-way switches, relays, thermostats, gateway, etc.).
3. Start the View Wireless App and log in with the credentials you just created.
4. Create the system and the environments.
5. Associate all the devices with the environments, except for the gateway (which should be
associated last).
6.
For every device, set the function, the parameters and any accessory devices (wired or radio
control and related function).
7. Transfer the configuration of the devices to the gateway and connect it to the Wi-Fi network.
8. Transfer the system to the Administrator user (who must have created his/her profile on
MyVIMAR).
For details, see the View Wireless App manual that can be downloaded from the www.
vimar.com website.
FIRST HEAD START-UP AND CONFIGURATION IN
1. Screw the thermostatic head onto the radiator and insert the batteries as illustrated in
"INSTALLATION AND BATTERY INSERTION."
After inserting the batteries, the display will show an animation in the central area:
2. Press the button to start calibration or wait 5 min.
During calibration, the display remains off.
At the end of calibration (which takes approximately 30 seconds), the display will show the
room temperature for 2 seconds and then turn off, entering standby mode.
2 s
°C
3. Start the View Wireless App and view the additional devices screen.
A
Display
: Touch keys for setting and operation
: Bluetooth configuration.
- ON: head working correctly
- OFF; head not configured
- Slow flashing: head configured but not connected to the network
- Rapid flashing: head configuration in progress
: Head in ON mode active
: Flat battery signal
°C = degrees Celsius
BTemperature sensor
C
Push button to access the battery compartment
D
Hooking ring
A
°C
C
D
B
4. Select “Add” ( ), choose the environment to place the head and give it a name.
5. Select ; activate the Bluetooth connection on your tablet/smartphone and approach the
head with it.
6. Press the
button briefly to exit standby.
°C
7. Press the button again for 3 s; the display flashes twice and shows the set point after 3 s.
Press buttons and on the head simultaneously for 6 s.
°C
°C °C
3 s
°C

Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
03989 01 2505
03989 - IoT connected thermostatic head
VIEW WIRELESS SMART HOME
The icon starts flashing and the association is completed.
°C
HEAD OPERATION
The thermostatic head always operates in heating mode, either ON or OFF.
Standby
When the head is in standby, its display is off. To reactivate it, briefly press the
button.
°C
Operating mode
Briefly press the button.
°C
• If the operating mode is ON, you'll see the temperature setpoint and can also modify it.
°C
• If the operating mode is OFF, the display won't show any value.
Temperature set point setting
1. When the thermostatic head is in ON mode, press one of the buttons and they and
will both start flashing.
2. Again using
and set the desired set point (each press increases or decreases by
0.5 °C).
The display will revert to showing the room temperature and after a 5-second timeout without
interaction with the device, the thermostatic head will go into standby with the display off.
OFF ON switching
After activating the display, press the
button for 3 s.
°C
the display flashes twice and switches ON, showing the set point and the and buttons.
°C
°C
ON OFF switching
After activating the display, press the
button for 3 s.
°C
The display turns off and switches OFF.
°C
N.B. After a 5-second timeout without interaction with the device, the thermostatic head will go
into standby and the display will turn off.
RESET PROCEDURE.
The reset restores the factory settings.
With the head in ON mode, press the
and buttons until the display does not show any
value.

Viale Vicenza 14
36063 Marostica VI - Italy
www.vimar.com
03989 01 2505
03989 - IoT connected thermostatic head
VIEW WIRELESS SMART HOME
Parameter settings via the View Wireless App
Independent thermostatic head:
Menu Parameters
Function Flat battery push notification
ON or OFF
Function Temperature calibration
± 5 °C
Thermostatic head associated with thermostat 30811-02974:
Menu Parameters
Function Flat battery push notification
ON or OFF
INSTALLATION RULES.
• Installation must be carried out by qualified persons in compliance with the current regula-
tions regarding the installation of electrical equipment in the country where the products are
installed.
• Hook the head onto the radiator before inserting the batteries and before performing
configuration.
• The mechanical installation of head 03989 in the radiator affects the error in the temperature
measurement; depending on whether the head is installed at the base of the radiator or at
the top of it, the room temperature measured can even differ by 2-3°C.
• After completing installation, we recommend you perform a calibration by placing a thermom-
eter in the room, at a height of 1.5 metres and at a distance of at least 3 metres from any
heating elements, to detect the temperature difference between the thermometer's measure-
ment and that of the thermostatic head. If necessary, calculate the average value between
the two measurement differences obtained with the radiator 'hot' and 'cold'; this value should
then be entered into the View Wireless App in the 'Winter Temperature Calibration' parameter
of the thermostatic head.
• The head is inserted in the Bluetooth mesh network and therefore needs at least one mains
powered IoT device (control, etc.) to be within its radio range. The head cannot operate in
stand-alone mode.
CHARACTERISTICS.
• Power supply: 3 V DC with 2 rechargeable AA alkaline LR6 1.5 V batteries (not provided)
• Battery life: up to 2 years.
The head stores the configuration assigned and retains it even in the event of a power
outage.
WEEE - User information
The crossed out bin symbol indicates that the product must be sent to separate collection facilities for recov-
ery and recycling, in compliance with the national laws of EU Countries that implement the WEEE Directive.
The objective is to prevent any harmful effects on the environment and on human health by ensuring that
products are disposed of correctly, avoiding illegal disposal sanctioned by law.
To dispose of the product correctly, please check local dispositions in your country.
• RF transmission power: < 100mW (20dBm)
• Frequency range: 2400-2483.5 MHz
• Max no. of heads per system: 24
• Display for adjustment and configuration
• Current settable setpoint: +4 - +40 °C
• Operating modes: Automatic, Manual, Reduction, Economy, Protection, Off, Timed Manual
• Heating adjustment in PI mode
• ErP classification (EU Reg. 811/2013): class IV temperature control device (contribution 2%)
• Temperature measurement precision (built-in probe): +/-1°C between +5 and 35°C
• Adaptors supplied for compatibility with the main valves: RA Danfoss, RAV Danfoss, RAVL
Danfoss, Giacomini, Caleffi, M28x1.5, FAR.
• Protection degree: IP30
• Operating temperature: -T35 (5 °C ÷ +35°C) (internal use)
• Degree of pollution: 2 (normal)
• Tracking index: PTI175
• Room temperature during transportation: -25 - +60°C
• Software class: A
• Controllable via View App, Amazon Alexa, Google, Siri and Homekit voice assistant for
Bluetooth technology system
REGULATORY COMPLIANCE.
RED Directive. RoHS directive.
Standards EN IEC 60730-2-7, EN 60730-2-9, EN IEC 63000, EN 301 489-17, EN 300 328,
EN IEC 62311.
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full text
of the EU declaration of conformity is on the product sheet available on the following website:
www.vimar.com
Temperature control device regulation (EU) no. 811/2013
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
INSTALLATION AND BATTERY INSERTION
CAUTION:
The product contains bat-
teries; please dispose of the
product in accordance with
your local municipal waste
disposal guidelines
WARNING:
Keep new and old batteries
out of children’s reach. Do
not handle the battery incor-
rectly: do not recharge it,
disassemble it, expose it to
fire or high temperatures. Do
not immerse, wet, or throw
the battery in water. In case
of battery leakage, do not
directly touch the spilled liq-
uid. Avoid contact with skin,
eyes, and clothing.
1
2
Produktspecifikationer
Varumärke: | Vimar |
Kategori: | Termostat |
Modell: | 03989 |
Behöver du hjälp?
Om du behöver hjälp med Vimar 03989 ställ en fråga nedan och andra användare kommer att svara dig
Termostat Vimar Manualer
24 Augusti 2025
24 Augusti 2025
24 Augusti 2025
23 Augusti 2025
30 December 2025
30 December 2025
16 December 2024
16 December 2024
16 December 2024
16 December 2024
Termostat Manualer
- Tesla
- Mikoterm
- Bulex
- Finder
- Nexa
- Coati
- Carrier
- Ambiano
- ELKO
- Heatmiser
- Go Green
- ChiliTec
- Max
- Tru Components
- GENERAL Life
Nyaste Termostat Manualer
24 Augusti 2025
24 Augusti 2025
24 Augusti 2025
24 Augusti 2025
24 Augusti 2025
24 Augusti 2025
24 Augusti 2025
24 Augusti 2025
24 Augusti 2025
24 Augusti 2025