Läs gratis den bruksanvisning för ABB DY365 4CE (1 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 5 personer och har ett genomsnittsbetyg på 4.9 stjärnor baserat på 3 recensioner. Har du en fråga om ABB DY365 4CE eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/1

User manual
DY365 4CE REMOTE ACTUATOR
Read all instructions carefully
• The DY365 4CE remote actuator is a four-relay electronic device that receives the command signals
from the switch via DY365 I/O extension ports.
It performs actions of 1B type and is intended to operate in a domestic and similar environment
with overvoltage category III and normal pollution degree (EN 60730-1).
SAFETY WARNINGS
During product installation and operation it is necessary to observe the following
instructions:
1) The device must be installed by a qualified person
2) Before accessing the terminals, make sure that the leads are not live
3) Do not power the device if any part of it is damaged
4) Connect the product following the diagrams described in this manual
5) In the electrical system upstream of the device must be installed a switch and a
protection device against the overcurrents.
6) The product must be installed and activated in compliance with current electric
systems standards.
7) After installation inaccessibility to the terminals without using dedicated tools
must be guaranteed.
Code Model Description
2CSM221181R1000 DY365 4CE 4-channel remote actuator
TECHNICAL FEATURES
• Power supply: 12/24 V AC/DC (-15%/+10%) 50/60 Hz
• 4 relays normally open 8A / 250 V AC
• I/O extension port for connection to the switchDY365
• Operating temperature: 0 ÷ +50 °C
• Storage temperature: -25 ÷ +70 °C
• Container: 4 DIN modules
• Protection degree: IP20 (IP40 when correctly installed in the electrical panel)
OPERATION
• When switched on, the red LEDs emit 2 flashes lasting half a second (switch-on sequence).
• Once the switch-on sequence is completed, the green LED is lit to indicate normal device
operation and the red LEDs are turned on/off to indicate the corresponding status of the
4 channels (on = ON).
Channels configuration
• During normal operation, press and hold the SET button for at least 3 seconds to enter
in configuration mode. In this mode the green LED is off while the red LED
corresponding to the relay to be configured flashes.
• To select the relay to be associated with the channel of DY365 switch , press the SET
button until the red LED for the relay to be configured flashes.
• Once the channel is selected, the actuator remains in configuration mode for 60 seconds:
activate the channel configuration on the DY365 switch.
To activate the channel configuration, see the DY365 switch user manual.
• Once the relay configuration is complete, the actuator resumes normal operation
• To cancel the configuration of a channel, enter the configuration mode, select the channel
with the SET button (relative red LED flashing), then press the SET button for at least three
seconds until the green LED lights up again.
Each new configuration cancels the previous configuration
REFERENCE STANDARDS
Compliance with Community Directives:
2014/35/EU (LVD)
2014/30/EU (EMCD)
is declared in reference to the harmonized Standards:
EN 60730-1
EN 301 489-1/3 and EN 300 220-3
Description
Connection diagram
8 A / 250 V ~
5
0
-
6
0
H
z
8 A / 250 V ~ 8 A / 250 V ~ 8 A / 250 V ~
Out 1
Out 2 Out 3 Out 4
2
3
0
V
~
I/O extension port
(B) (A)
Green LED for operating status signaling
Red LEDS for relay status signaling
SET BUTTON for channels programming and resetting
Dimensions (mm)
87 mm
72 mm
45 mm
60 mm
65 mm
DY365 4CE
2CSM441048D0201
ABB S.p.A
V.le dell’Industria 18
20010 Vittuone (MI) - Italy
Tel. +39 02 2415 0000
https://new.abb.com/low-voltage
© Copyright 2019 ABB S.P.A . All rights reserved.
We reserve the right to make technical changes or modify
the contents of this document without prior notice.
Installation Manual
Produktspecifikationer
Varumärke: | ABB |
Kategori: | Inte kategoriserad |
Modell: | DY365 4CE |
Färg på produkten: | Black, White |
Vikt: | 23000 g |
Bredd: | 550 mm |
Djup: | 920 mm |
Höjd: | 1160 mm |
Antal program: | 17 |
Transport wielen: | Ja |
Träningsparametrar visas: | Calories, Distance, Evolutions per minute (RPM), Heart rate, Speed, Time |
Max användarvikt: | 100 kg |
Flaskhållare: | Nee |
Svänghjulets vikt: | 6000 g |
Pulsmätare som tillval: | Nee |
Kör system: | V-riem |
Standard pulsmätare: | Handgreepsensoren |
Sadeljustering: | Verticaal/Horizontaal |
Behöver du hjälp?
Om du behöver hjälp med ABB DY365 4CE ställ en fråga nedan och andra användare kommer att svara dig
Inte kategoriserad ABB Manualer
6 Oktober 2024
18 September 2024
10 September 2024
8 September 2024
29 Augusti 2024
29 Augusti 2024
25 Augusti 2024
24 Augusti 2024
24 Augusti 2024
20 Augusti 2024
Inte kategoriserad Manualer
- Apantac
- Carnielli
- Hover-1
- PCTV Systems
- Makita
- BISWIND
- Kernau
- Gioteck
- Sogo
- SPT
- Dragonshock
- Anova
- ATN
- Bunn
- Polti
Nyaste Inte kategoriserad Manualer
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025
9 April 2025