Alula RE218T Bruksanvisning


Läs gratis den bruksanvisning för Alula RE218T (2 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 32 personer och har ett genomsnittsbetyg på 4.6 stjärnor baserat på 16.5 recensioner. Har du en fråga om Alula RE218T eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/2
Flood and Temp Sensor is an integrated environmental
sensor. It detects ood conditions and reports extreme
temperatures.
Features
Titanium probes for unmatched corrosion immunity
IP67 rated waterproof enclosure
GORE
®
vent to prevent seal failure
5 year warranty
Enroll by placing the panel into wireless enrollment mode and
removing the battery tabs, tampering the sensor, or manually
entering the sensor ID. NOTE, this sensor requires rmware
version 1.14 or later for GC2 Panel and 3.1 or later for
CG3. For older panel rmware versions, use the RE218
Honeywell
®
Compatible Flood and Temp Sensor.
Panel Questions Flood Heat Freeze
Sensor Type
[08] 24 Hour
Aux. Alarm
[08] 24 Hour
Aux. Alarm
[08] 24 Hour
Aux. Alarm
Equipment Type [8] Water [10] Temp. [6] Freeze
Equipment Code
[1065] 2GIG
Flood Sensor
[1065] 2GIG
Flood Sensor
[1065] 2GIG
Flood Sensor
Sensor Age [0] New [0] New [0] New
Loop Number [1] Flood [2] Heat [3] Freeze
Install by placing the sensor in the location requiring ood or
temperature detection. If desired, the wall clip can be used
to secure the sensor.
Optional Screw Mounting
Remove the wall clip from the sensor body.
Secure the clip to a wall, baseboard or cupboard
using a #6 screw.
Slide the sensor body down onto the wall clip until
it snaps into place.
Sensor detects water pooled under the sensor and reports
extreme temperature conditions.
Temperature Trip Points
Heat alarms when over 100°F (38°C)
Heat restores when under 97°F (36°C)
Freeze alarms when under 45°F (7°C)
Freeze restores when over 48°F (9°C)
To replace the batteries, insert a at blade screwdriver into
the front slot and twist. Slide both old batteries out and the
new batteries in. To reinstall the cover, align the rear latches
and roll the cover forward until it snaps into place.
I
N
S
T
A
L
L
G
U
I
D
E
I
Verify proper enrollment and operation using your control panel’s installation manual.
Front slot
Mounting Screw Hole
Wall Clip
RE218T Flood & Temp Sensor
2GIG
Compatible
Resolution Compatibles


Produktspecifikationer

Varumärke: Alula
Kategori: Inte kategoriserad
Modell: RE218T

Behöver du hjälp?

Om du behöver hjälp med Alula RE218T ställ en fråga nedan och andra användare kommer att svara dig