CDN ProAccurate INTP662 Bruksanvisning

CDN Termometer ProAccurate INTP662

Läs gratis den bruksanvisning för CDN ProAccurate INTP662 (5 sidor) i kategorin Termometer. Guiden har ansetts hjälpsam av 7 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 4 recensioner. Har du en fråga om CDN ProAccurate INTP662 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/5
for non-contact and internal temperatures
•NSF
®
Certified
•1&3secondresponses
•1.5mmthintip
•3.75”(9.53cm)probe
•Infraredfornon-contactsurfacetemperatures
•Thermocoupleprobeforinternaltemperatures
•Dualfunction
•Maximum,minimumandlockmodesforcontinuous
scanning
•8-beamlasertargetillumination
•Distance:Spot=8:1
•Data-hold
•One-buttonoperation
•BacklitHACCPchecklights
•Batterystatusindication
•Food-safeABSplasticwithBioCote
®
•Stainlesssteelprobe
Auto-off
•Batteryandinstructionsincluded
Get Professional Results
Every Time!
Monitoringtemperatureisessentialtokeepingfoodsafe.
TheversatileINTP662isapowerhousekitchentool.
Simplypointtheinfraredguntowardthetargetandpress
thetriggertogetaquickreadingofsurfacetemperatures
orflipdowntherapid-responsethermocoupleprobeto
measureinternaltemperatures.IntegratedHACCPcheck
backlightinginstantlyshowsiftemperaturesarewithin
HACCPguidelinesforsafefoodtemperatures.
Minimum, Maximum and Lock
TheINTP662alsooffersMinimum,Maximum,andLock
modes.Minimummodedisplaysthelowesttemperature
amongmultipletargets.Maximummodedisplaysthe
highesttemperatureamongmultipletargets.WhileLock
modecontinuouslydisplaysthetemperatureforupto
60minutes.Thisisparticularlyusefulforcontinuous
temperaturemonitoring.
Note:Removestickerfromdisplaybeforeuse.Cleanthe
thermometerprobebeforeeachuse.
Important: DO NOT LEAVE THERMOMETER IN HOT OVEN.
HAND WASH AND DRY. DO NOT IMMERSE HOUSING IN
LIQUID.
Note:Inthefollowinginstructions,namesofthecontrol
buttonsareshowninCAPS.Functioninformationthat
appearsonthedisplayisshowninBOLD CAPS.
Battery Installation
ReplacebatterywhenLCDbecomesdim.Poweroffthe
unitbeforeinstallingthebatteries.Amalfunctionmay
occurifthepowerisonwhenthebatteryisinstalled.Ifa
malfunctionoccurs,restartthedevice.
1.Removebatterycoverbyslidingitdownalongthe
handle.
2.Installtwo1.5VAAAbatteriesobservingpolarity
shownincompartment.
3.Replacethebatterycoveruntilitclicksshut.
Model: INTP662
ProAccurate
®
Infrared Gun/
Thermocouple Thermometer
Infrared:-76to+662°F/-60to+350°C
Thermocouple:-76to+662°F/-60to+350°C
Operating Instructions
Mode Selection:MINØMAXØLOCKØ°C/°FØEMIS
A. Temperature Scale
ToselecttemperaturereadinginFahrenheitorCelsius:
1.Pressthetriggertoturnthethermometeron.
2.PresstheMODEbuttonfourtimes.The°F or °C
symbolflashesonthedisplay.
3.PresstheSCANbuttontochangethescale.
B. Infrared Thermometer
InfraredisthedefaultmodeoftheINTP662.
Note:TheINTP662isintendedforfoodserviceuse—donotuse
forsafetyrelatedapplications.
1. Infrared Scanning
a. Distance:Spot = 8:1
Forexample,ifthe
surfaceareabeing
measuredis10"in
diameter,thenthethermometermustbewithin
80"ofthetargetforanaccuratereading.
b. Aimtheinfraredlensatthetargetandpress
thetriggertodisplaythesurfacetemperature.
The8-beamlaserlightautomaticallyilluminates
thetarget,specifyingtheapproximate
measurementareaforbettertargeting.
c. The8-beamlaserlightformsacirclethat
definestheareaofmeasure.Makesurethe
circleissmallerthantheareabeingmeasured.
Ifthelaserlightcircleislargerthanthearea
beingmeasured,thereadingwillincludeambient
temperaturesandmakethereadinginaccurate.
d. Measurementcontinuesaslongasthetrigger
ispressed.Thenewestreadingupdatesthe
display.
e. Whenthetriggerisreleased,HOLD appears on
thedisplayandthelastreadingremainsvisible
for15secondsbeforetheunitautomatically
powersoff.
2. Minimum Mode
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttononce.MIN flasheson
thedisplay.
c. PressthetriggertoconfirmtheMinimumMode
anddisplaythelowesttemperatureamong
multipletargets.MIN remainsonthedisplay.
d.Thethermometercontinuestodisplaythe
minimumreadingduringeachmeasurement
perioduntiltheMODEbuttonispressedagainor
theunitpowersoff.
3. Maximum Mode
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttontwice.MAX flasheson
thedisplay.
c. PressthetriggertoconfirmtheMaximumMode
anddisplaythehighesttemperatureamong
multipletargets.MAX remainsonthedisplay.
d.Thethermometercontinuestodisplaythe
maximumreadingduringeachmeasurement
perioduntiltheMODEbuttonispressedagain
ortheunitpowersoff.
4. Lock Mode
Thisisparticularlyusefulforcontinuous
temperaturemonitoring.
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttonthreetimes.LOCK
flashesonthedisplay.
c. PressthetriggertoconfirmtheLockMode.
The°F or °Csymbolflashesonthedisplay.
d. Thethermometercontinuouslydisplaysthe
temperatureforupto60minutesoruntilthe
triggerispressedagain.
5. Emissivity
Everythinggivesoffacertainamountofradiation.
Emissivityisthemeasureofthisthermalradiation.
Theinfraredthermometerissuppliedwithadefault
emissivityof0.95,whichstandardformostuses.
Theemissivityofthethermometercanbechanged
from0.10(10E)to1(100E).Only experienced
personnel should attempt to make changes.
Forinformationrelatingtotheemissivityofspecific
materials,pleasecontactCDN.
a. Pressthetriggertoturnthethermometeron.
b. PresstheMODEbuttonfivetimestoenter
EmissivityMode.95E flashesonthedisplay.
c. Pressthetriggertoadjusttheemissivityvalue
in0.01(1E)increments.
d. PresstheMODEbuttonagaintoexit
EmissivityMode.
Note:Non-contactinfraredthermometersarenot
recommendedforuseinmeasuringthetemperatureof
shinyorpolishedmetals.
6. Error Messages
TheINTP662incorporatesvisualdiagnostic
messagesasfollows:
a. HI or LO isdisplayedwhenthetemperature
beingmeasuredisoutsidetheinfraredrange
oftheinstrument.
1.)HI indicatesthatthetemperatureishigher
than+662°F/+350°C.
2.)LO indicatesthatthetemperatureis
lowerthan-76°F/–60°C.
b. Allowaminimum30minutesforthe
thermometertostabilizetotheworking/room
temperature.
Distance:Spot(FOV)=8:1
Emissivity=0.1~1,Step.01
WaveLength=8~14µm
CAUTION: Never point the unit and/or laser towards
anyone’s eyes. Do not look directly into the laser
beams — permanent eye damage may result. Keep
away from children.


Produktspecifikationer

Varumärke: CDN
Kategori: Termometer
Modell: ProAccurate INTP662

Behöver du hjälp?

Om du behöver hjälp med CDN ProAccurate INTP662 ställ en fråga nedan och andra användare kommer att svara dig