Läs gratis den bruksanvisning för Draper Expert 07030 (2 sidor) i kategorin pump. Guiden har ansetts hjälpsam av 3 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 2 recensioner. Har du en fråga om Draper Expert 07030 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/2

Draper Tools
Draper Tools Limited
Hursley Road, Chandler’s Ford
Eastleigh, Hampshire, SO53 1YF UK
EN
Original Instructions
Version 1
Version 1: December 2024
First release
Read this manual in full before using this product and retain it
for future use. Always use the latest version of the manual.
Please visit
drapertools.com/manuals for the latest
version.
1. Intended Use
This battery-operated pump is designed for quick and easy
transfer of a wide range of uids. The pump will t 20 Litre
drums/buckets and is self-priming. For use with Water,
Gasoline, Diesel, Light Oils,Kerosene, Diesel Exhaust Fluid
(DEF/ Adblue), Antifreeze, Windshield Washer Fluid, Mild
Detergents & Agricultural Chemicals.
Any other application beyond the conditions established for
use will be considered misuse. Draper Tools accepts no
responsibility for improper use of this product.
2. Specication
Stock No.: 07030
Part No.: BOD/APP
Drum size: 20litres
Flow Rate: 10 L/min
Batteries required: 2 × D /LR20 (not supplied)
Operating Temperature: 5 – 40°C
Flexible Hose Length: 600mm
Operating Temperature: 5 - 40°C
Recommend Use: Diesel, kerosene, light oils,
diesel exhaust fuel, water,
antifreeze, mild detergents and
agricultural chemicals.
07030
DEF/ADBLUE PUMP
BATTERY OPERATED
3. HealthandSafetyInformation
Important: Read all the Health and Safety instructions
before attempting to operate, maintain or repair this product.
Failure to follow these instructions may result in injury or
damage to the user or the product.
WARNING!
•
DO NOT run the pump dry.
•
DO NOT use with acids, acetone, benzene, cresol,
concentrated caustic soda, liquid thinner or other
solvents.
•
DO NOT use with deteriorated or contaminated liquids or
fuels.
•
DO NOT use the pump for hot liquids above 40°C.
•
DO NOT operate the pump for longer than 15 minutes
without a 30-minute rest.
•
DO NOT turn the pump upside down after use.
•
ALWAYS ensure the pump is turned ‘OFF’ and liquid has
been drained from the pump before cleaning.
•
DO NOT use abrasives or solvents to clean the pump.
•
ALWAYS wear suitable protective clothing and eye
protection.
• Wear suitable protective gloves to avoid repeated and
prolonged contact of uids with the skin.
• Keep the work area clean and dry. DO NOT use in damp or
wet areas.
•
DO NOT modify the pump and DO NOT use for a purpose
it was not intended.
• Before using the pump check for damaged parts and that
it operates correctly. Replace any damage parts
immediately.
• Keep the pump away from heat and sharp edges. Before
each use check the pump for wear and ensure all
connections are secure.
Delta International
Delta International BV
Oude Graaf 8
6002 NL
Weert
Netherlands
Website: drapertools.com
Email: sales@drapertools.com
Product Helpline: +44 (0) 23 8049 4344
Telephone Sales Desk: +44 (0) 23 8049 4333
General Enquiries: +44 (0) 23 8026 6355
© Published by Draper Tools Limited

4. Identication
Carefully remove the product from the packaging and
examine it for any signs of damage that may have occurred
during shipment. If any part is damaged or missing, do not
attempt to use the product. Please contact the Draper
Helpline; contact details can be found at the back of this
manual.
3
2
5
6
1
4
1. ON/OFF switch
2. Battery compartment
3. Nozzle
4. Nozzle holder
5. Flexible transfer hose
6. Suction tube
5. FittingorReplacingBatteries
2 × D batteries required (not supplied).
1. Unscrew the battery compartment
2
.
2. Fit 2 × D batteries – ensure the correct +/- orientation.
− Refer to the guide marked on the battery
compartment.
3. Ret the battery compartment securely.
6. OperatingthePump
1. Insert the end of the suction tube
6
into the
container/drum with the uid to be transferred from.
2. Place the end of the nozzle
3
into the container
that the uid is being transferred into.
3. Slide the switch
1
to the ‘ON’ position to start
dispensing the uid.
7. Maintenance,StorageandDisposal
• ALWAYS ensure the pump is turned ‘OFF’ and liquid
has been drained before cleaning or carrying out any
maintenance.
• DO NOT abrasives or solvents to clean the pump.
• Store the nozzle in the holder after use.
• Remove the batteries if being stored for a prolonged
period.
• At the end of its working life, dispose of the product
responsibly and in line with local regulations. Recycle
where possible.
•
DO NOT dispose of this product with domestic waste;
most local authorities provide appropriate recycling
facilities.
• DO NOT burn or mutilate batteries; this may release
toxic or corrosive substances.
9. Warranty
12 months from date of purchase –
Visit drapertools.com/warranty for full details.
10. Symbols
Read the instruction
manual
WEEE – Waste Electrical &
Electronic Equipment
Do not dispose of Waste
Electrical & Electronic
Equipment in with domestic
rubbish
European conformity
UK Conformity Assessed
Warning!
Do not incinerate or throw
onto re
Wear suitable eye protection
Wear suitable personal
protective equipment (PPE)
Produktspecifikationer
Varumärke: | Draper |
Kategori: | pump |
Modell: | Expert 07030 |
Behöver du hjälp?
Om du behöver hjälp med Draper Expert 07030 ställ en fråga nedan och andra användare kommer att svara dig
pump Draper Manualer
25 September 2025
25 September 2025
pump Manualer
- Yamazen
- Nedis
- WilTec
- Brightwell
- Könner & Söhnen
- Lezyne
- Gude
- Hozelock
- Gloria
- BBB
- Wagner
- Ribimex
- Laguna
- Black Decker
- Stanley
Nyaste pump Manualer
25 September 2025
25 September 2025
25 September 2025
24 September 2025
21 September 2025
21 September 2025
21 September 2025
20 September 2025
19 September 2025
19 September 2025