Läs gratis den bruksanvisning för Klein Tools MM6000 (8 sidor) i kategorin Multimeter. Guiden har ansetts hjälpsam av 14 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 7.5 recensioner. Har du en fråga om Klein Tools MM6000 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/8

ENGLISH
Instruction
Manual
ENGLISH
MM6000
RANGE
4007036
~
-
AT
O
.L.
Apo
MIN
M
AX
%
V
A
Ω
F
n
-9
µ
m
-3
k
3
M
°F
°C
A- HOLD
LOW
Z
600mV
˜
600V 0.1mV
˜
0.1V ± (0.2% + 5 digits)
1000V 1V ± (0.5% + 10 digits)
1000V : >10MΩ, <100pF
: >3kΩ, <200pF, up to 600V RMS
40Hz ~ 400Hz
400Hz ~ 2kHz
600mV 0.1mV
± (0.75% + 5 digits)
± (2.5% +10 digits)
6V ~ 600V 1mV ~ 0.1V ± (2.0% + 8 digits)
1000V 1V ± (0.75% + 8 digits) ± (2.0% +8 digits)*
Continued on next page.
1000V RMS : >10MΩ, <100pF
: >3kΩ, <200pF, up to 600V RMS
40 to 2kHz True RMS
*Accuracy for 400Hz ~ 1kHz range only.
600μA ~ 400mA 0.1μA ~ 0.1mA ± (1.0% + 5 digits)
6A ~ 10A 1mA ~ 10mA ± (1.5% + 5 digits)
400mA (F440mA/1000V fuse) /10AF11A/1000V fuse)
40Hz ~ 2kHz
600μA ~ 400mA 0.1μA ~ 0.1mA ± (1.2% + 5 digits)
6A ~ 10A 1mA ~ 10mA ± (1.8% + 5 digits)
400mA (F440mA/1000V fuse) /10AF11A/1000V fuse)
40 to 2kHz True RMS
600Ω
˜
6MΩ 0.1Ω
˜
0.001MΩ ± (1.0% + 5 digits)
50MΩ 0.01MΩ ± (1.5% + 10 digits)
600V RMS
60nF 0.01nF
± (3.5% + 6 digits)
600nF ~ 6000μF 0.1nF ~ 1μF
600V RMS
99.99Hz
˜
399.9kHz 0.01Hz
˜
0.1kHz ± (0.1% + 3 digits)
600V RMS 2.5V RMS
1.0
˜
99.0% 0.1% ± (0.2% per kHz + 0.1% + 8 digits)
600V RMS Sensitivity: < 50V RMS
0.5Hz to 10kHz
600V RMS 6.0V DC 0.25mA
<
1.8V DC
600V RMS
<
0.44V <40Ω
-58 ~ 600°F 0.1°F ± (1.0% + 5.4°F)
-50 ~ 600°C 0.1°C ± (1.0% + 3.0°C)
600 ~ 1832°F 1°F ± (1.0% + 5.4°F)
600 ~ 1000°C 1°C ± (1.0% + 3.0°C)
600V RMS Not specifi ed
Specifi cations subject to change.
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period
of time. Do not expose to high temperatures or humidity. After a period of
storage in extreme conditions exceeding the limits mentioned in the General
Specifi cations section, allow the instrument to return to normal operating
conditions before using it.
Do not place equipment and its accessories in the trash.
Items must be properly disposed of in accordance with local
regulations
.
Prior to disposal of this product, please contact Klein Tools
for proper disposal options.
• Fahrenheit range: -58° to 1832°F (Celsius range: -50° to 1000°C).
Features:
REL
• When selecting uA or mA/A functions the meter will indicate
“” if the test leads are not properly connected to the meter.
• Note: This message remaining on the screen after properly
connecting the test leads is an indication that the fuse is open.
450 Bond Street
Lincolnshire, IL 60069
Rev 04/14 B 139750
Features:
• Press SELECT to choose AC or DC Voltage.
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• See AC/DC Voltage instruction.
Capacitance Features:
• Reading may take up to 60 seconds
for large capacitors.
1000V
10A
Dwg Name: MM6000-139750ART Dwg No: 139750
ECO No: 016671 Pkg Dwg Ref: 1650 Rev: B
Color Reference: CEN-PACK-003-A
MM6000-139750ART-Instructions.indd 1-4 5/5/14 10:19 AM

ENGLISH
The Klein Tools MM6000 is a True RMS, auto-ranging multimeter.
It measures AC/DC voltage, low impedance voltage, AC/DC current,
resistance, capacitance, frequency, duty cycle, and temperature. It can also
test diodes and continuity.
• 6,562 ft. / 2,000 m
• 75%
• 32°F to 113°F (O°C to 45°C)
• -4°F to 140°F (-20°C to 60°C) <80% R.H.
• 18°C to 28°C (64°F to 82°F)
• 0.1*(specified accuracy)/ °C
• 3 samples per second
• 7” x 3.5” x 1.875” (178 x 89 x 48 mm)
• 14 oz. (397 g)
• 160 Hours
• 3 m
• 20
• Accurate for one year
• ± (% of reading + # of least significant digits)
• CAT III 1000V, CAT IV 600V
• Conforms to UL Stds 61010-1 & 61010-2-030.
Certified to CAN/CSA C22.2 No.61010-1, 61010-2-030,
IEC 61010-2-030:2010 MOD, ANSI/ISA-61010-2-030 (82.02.03).
• 2
• USA (of US and imported parts)
To ensure safe operation and service of the tester, follow these instructions.
Failure to observe these warnings can result in severe injury or death.
• Before each use, verify meter operation by measuring a known
voltage or current.
• Never use the meter on a circuit with voltages that exceed the
category based rating of this meter.
• Do not use the meter during electrical storms or in wet weather.
• Do not use the meter or test leads if they appear to be damaged.
• Ensure meter leads are fully seated, and keep fingers away from the
metal probe contacts when making measurements.
• Do not open the meter to replace batteries or fuses while the probes
are connected.
• Use caution when working with voltages above 60V DC or 25V AC
RMS. Such voltages pose a shock hazard.
• To avoid false readings that can lead to electrical shock, replace
batteries if a low battery indicator appears.
• Unless measuring voltage or current, shut off and lock out power
before measuring resistance or capacitance.
• Always adhere to local and national safety codes. Use individual
protective equipment to prevent shock and arc blast injury where
hazardous live conductors are exposed.
~
C
E
A
G
F
H
J
I
L
K
N
B
5
8
3
2
Features:
RANGEREL
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• Rotate selector to "AC" Voltage position.
• Attach RED lead to “V” input, BLACK lead to COM.
Features:
RANGEREL
Features:
• Attach RED lead to “μA” input, BLACK lead to COM.
• Break circuit and connect meter in series (AS ABOVE).
• Select AC or DC current source.
Continuity Features:
• Display shows resistance.
• Buzzer sounds if less than 40Ω.
Diode Features:
Display shows:
• Forward voltage drop if forward biased.
• “O.L” if reverse biased.
RANGEREL
Resistance Features:
•
measure resistance on a live
circuit.
Ω = < 50MΩ.
REL
RANGE
• Start with this setting if current level is unknown.
• Break circuit to be measured.
• Attach RED lead to "A" input, BLACK lead to COM.
• Connect RED lead to one side of break and BLACK lead to the
other (meter in series).
• Meter will automatically select "A" when RED lead is connected to
"A" input. “” will show if connected but fuse is blown.
Features:
RANGEREL
• Use Low Impedance (LOW Z) mode to reduce ghost voltages.
• Rotate selector to "DC" Voltage position.
• Attach RED lead to “V” input, BLACK lead to COM.
• Device will power off after 30 minutes non-use.
• Press the select button to wake.
• Disabled during Max/Min function.
• Holding Select button while turning on disables Auto Power-Off.
• Switch between AC and DC.
• Switch between “Ω”, “
”, “ ”, and “ ”.
• Switch between Hz and %.
• Switch between °F and °C.
• Wake meter during Auto Power Off.
• Press to store current value.
• Display shows the difference between the stored and live readings.
• Press again to return to live reading.
• Press repeatedly to cycle through manual ranges.
• Press for 2 seconds to return to auto ranging mode.
• AT is displayed on LCD only during auto ranging mode.
• Press to enter Max/Min mode; the largest and smallest values will be
saved while in this mode.
• Press repeatedly to alternate between the maximum and minimum
readings.
• Press for 2 seconds to return to live reading and clear the stored
maximum and minimum values.
• Hold captures the current displayed value.
• Auto Hold captures the first stable displayed value, until a new stable
value is measured. The meter will then capture the new value and emit
a beep (V, Ohm, Temperature and Amp functions).
• Press to hold current input on the display.
• Press again to enter Auto-Hold to capture stable values.
• Press again to return to normal operation.
• Press and hold to activate display backlight.
• Using lights drains the battery significantly.
• When indicator is displayed on the LCD, batteries must be
replaced.
• Remove rubber boot, back screw and replace 2 x AAA batteries.
• This meter uses 440mA/1000V (69192) and 11A/1000V (69191)
fast blow fuses.
(optional, sold separately)
• Slide magnetic adapter into protective rubber boot.
• Attach instruments to metal for hands-free use.
• The bar graph shows an approximate analog representation
of a measurement.
• The bar graph responds much faster than the digital display.
• The scale of the bar graph is zero to the maximum reading of
the selected range.
MM6000
Dwg Name: MM6000-139750ART Dwg No: 139750
ECO No: 016671 Pkg Dwg Ref: 1650 Rev: B
Color Reference: CEN-PACK-003-A
MM6000-139750ART-Instructions.indd 5-8 5/5/14 10:19 AM
Produktspecifikationer
Varumärke: | Klein Tools |
Kategori: | Multimeter |
Modell: | MM6000 |
Behöver du hjälp?
Om du behöver hjälp med Klein Tools MM6000 ställ en fråga nedan och andra användare kommer att svara dig
Multimeter Klein Tools Manualer
12 Juni 2025
12 Juni 2025
12 Juni 2025
29 December 2024
29 December 2024
16 September 2024
16 September 2024
16 September 2024
8 September 2024
Multimeter Manualer
- TFA
- CEM
- Profile
- Aldi
- Perel
- Multimetrix
- Digi-tool
- Kurth Electronic
- Biltema
- Vimar
- Topcraft
- Cosinus
- Parkside
- Joy-it
- Ideal
Nyaste Multimeter Manualer
2 Augusti 2025
2 Augusti 2025
1 Augusti 2025
1 Augusti 2025
1 Augusti 2025
1 Augusti 2025
1 Augusti 2025
1 Augusti 2025
1 Augusti 2025
31 Juli 2025