Läs gratis den bruksanvisning för Liftmaster CPS-U (8 sidor) i kategorin Inte kategoriserad. Guiden har ansetts hjälpsam av 16 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 8.5 recensioner. Har du en fråga om Liftmaster CPS-U eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/8
COMMERCIAL PROTECTOR SYSTEM®
INSTALLATION INSTRUCTIONS
To reduce the risk of SERIOUS INJURY or DEATH:
This device is for use ONLY on LiftMaster® Commercial Door
Operators.
For INDOOR USE ONLY.
Disconnect power BEFORE installing the Commercial Protector
System®.
READ AND FOLLOW ALL INSTRUCTIONS.
Facing the door from inside the garage (installation procedures are the same for all door types).
Left Side of Garage Right Side of Garage
Photoelectric Sensor
Photoelectric Sensor
Invisible Light Beam
Protection Area
THE COMMERCIAL PROTECTOR SYSTEM®
IMPORTANT INFORMATION ABOUT THE PHOTOELECTRIC SENSORS
Be sure power to the operator is disconnected.
When properly connected and aligned, the photoelectric sensors will detect an obstruction in the path of its invisible light beam. If an
obstruction breaks the light beam while the door is closing, the door will stop and typically reverse to the full open position.
The photoelectric sensors must be installed inside the garage so that the sending and receiving sensors face each other across the door,
no more than 6" (15 cm) above the fl oor. Either can be installed on the left or right of the door as long as the sun never shines directly
into the receiving eye lens. This product is not suitable for outdoor use.
The brackets must be securely fastened to a solid surface such as the wall framing. If installing in masonry construction, add a piece of
wood at each location to avoid drilling extra holes in masonry if repositioning is necessary.
The invisible light beam path must be unobstructed. No part of the garage door (or door tracks, springs, hinges, rollers or other
hardware) may interrupt the beam while the door is closing. If it does, use a piece of wood to build out each sensor mounting location to
the minimum depth required for light beam clearance.
APPLICATION
The Commercial Protector System® (CPS) is suitable for LiftMaster
Commercial Door Operators with a Normally Open (N.O.) sensing
edge input.
The CPS is for use with ancillary entrapment protection devices
only, and not used for primary monitored entrapment protection
devices.
CARTON INVENTORY
PART # DESCRIPTION QTY
CPS-U Photoelectric Sensors with Mounting Hardware 1
41K4629 Commercial Protector Interface 1
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov


Produktspecifikationer

Varumärke: Liftmaster
Kategori: Inte kategoriserad
Modell: CPS-U
Typ av operation: Knoppen
Färg på produkten: Zwart
Vikt: 420 g
Bredd: 88.9 mm
Djup: 96.77 mm
Höjd: 134.62 mm
Antal lampor: 1 lampen
Typ av lampa: LED
Strömlampa: 3 W
Kraftkälla: AC
siffra: 1
Frekvens: 601 Hz
Lämplig för inomhusbruk: Ja
Strålvinkel: 9 °
Strömförbrukning (typiskt): 5 W
Typ produkt: Disco-spotlight
Baldiameter: - "

Behöver du hjälp?

Om du behöver hjälp med Liftmaster CPS-U ställ en fråga nedan och andra användare kommer att svara dig