Manhattan 460835 Bruksanvisning
Manhattan
Streckkodsläsare
460835
Läs nedan 📖 manual på svenska för Manhattan 460835 (80 sidor) i kategorin Streckkodsläsare. Denna guide var användbar för 6 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/80

Barcode Scanner
Programming Quick Guide
manhattan-products.com


Programming Menu
V3.8 a
Notice
The manufacturer shall not be liable for technical
or editorial errors or omissions contained herein;
nor for incidental or consequential damages in
connection with the furnishing,performance or use
of use the publication.

1
Contents
Chapter 1 Description
1.1 Notice ....................................................... 3
1.2 Introduction ........................................... 4
1.3 Codes Read ........................................... 4
1.4 Installation .............................................. 4
1.5 Pin Assignment ...................................... 6
Chapter 2 Configuration - General
2.1 Flow Chart ............................................. 8
2.2 Loop of Programming ........................... 9
2.3 Factory Default Settings ........................ 9
2.4 Main Page of Configuration................... 10
Chapter 3 Interface and Reading Mode
Selection
3.1 Interface Selection ................................. 11
3.2 Memory Function .................................... 11
3.3 Reading Mode Selection ........................ 12
Chapter 4 Communication Parameters
4.1 RS232 Mode Parameters ...................... 13
4.2 Keyboard Wedge Mode Parameters..... 15
4.3 Output Characters Parameters ............. 17
4.4 Wand Emulation Mode Parameters...... 19
Chapter 5 Bar Codes & Others
5.1 Symbologies Selection ......................... 20
5.2 UPC/EAN/JAN Parameters ................... 24
5.3 Code 39 Parameters ............................. 26
5.4 Code 128 Parameters ........................... 28
5.5 Interleave 25 Parameters ...................... 30
5.6 Industrial 25 Parameters ....................... 32
5.7 Matrix 25 Parameters ............................ 34
5.8 CODABAR/NW7 Parameters ............... 36
5.9 Code 93 Parameters ............................. 38
5.10 Code 11 Parameters ............................. 40
5.11 MSI/PLESSEY Code Parameters ......... 42

2
5.12 Code 2 of 6 Parameters ......................... 44
5.13 LCD 25 Parameters ............................. 46
5.14 Telepen Parameters ............................. 48
5.15 GS1 DataBar (RSS Code) ........................ 50
Chapter 6 Miscellaneous Parameters
6.1 Language Selection .............................. 52
6.2 Bar Code ID .......................................... 54
6.3 Reading Level ........................................ 57
6.4 Accuracy ............................................... 57
6.5 Buzzer Beep Tone ................................. 57
6.6 LED Control .......................................... 57
6.7 Same Code Delay Reading lnterval ...... 58
6.8 Notebook Function ................................ 58
6.9 Reverse Output Characters .................. 59
6.10 Set Up Deletion ...................................... 59
6.11 Set Up Insertion ................................... 62
6.12 Set Up IR Sensor ................................... 65
Appendix
A. Decimal Value Tables ............................ 67
B. ASCII Tables .......................................... 68
C. Function Key Tables .............................. 72

3
Chapter 1 Description
1.1 General
Thank you for purchasing this barcode scanner with
an advanced and versatile decoder.The decoder
works with variety of barcode types,reading devices,
and computer interfaces.It discriminates over twenty
different symbologies automatically.
This menu provides an easy way to configure the
decoding options and interface selections by scan-
ning bar codes listed in the menu.
FCC Approval
This device had been tested in accordance with the pro-
cedures and in compliance with Part 15 Subpart B of FCC
Rules. And keeps all requirments according ANSI C63.4 &
FCC Part 15 B Regulation and CISPR22 Class B.
CE Standards
The CE mark as shown here indicates this product had
been tested in accordance with the procedures given in
European Council Directive 2004/108/EC and confirmed to
comply with the Europe Standard EN55022:2006:Class B,
EN 55024:1998+A1:2001+A2:2003,IEC61000-3-2:2006,
IEC61000-3-3:1995+A1:2005,IEC61000-4-2:2001,
IEC61000-4-3:2006,IEC61000-4-4:2004,IEC61000-4-5:
2006,IEC61000-4-6:2001,IEC61000-4-8:2001,IEC61000-4-
11:2004.

5
Power supply for RS-232C scanner–
There are 3 ways to supplying the power, use ex-
ternal +5V power supply, use optional power cable
(KBDC) which taking the power from KB wedge or
if the host supports +5V power from pin 9.
Installing the scanner to the Host System –
1. Turn off the host system.
2. Connect the power if needed.
3. Connect to the proper port on the host system.
4. Turn on the host system.
Switching cable –
Before removing the cable from the scanner, it is
recommended that the power on the host system
is off and the power supply has been disconnected
from unit.
1. Find the small “Pin-hole” on the bottom of the
unit.
2. Use a bended regular paperclip and insert the
tip into the hole.
3. You will head a “click”, then gentle on the strain-
relief of the cable and it will slide out of the
scanner.
SG/LG Series
SD Series

6
1.5 Pin Assignment
A> Input Port for Mini Decoder
DB 9 Male
Pin No. Wand / CCD /
Slot Reader Laser Scanner
1 N.C. S.O.S.
2 DATA DATA
3 N.C. N.C.
4 N.C. N.C.
5 N.C. TRIGGER
6 N.C. P. E.
7 GND GND
8 SHIELD SHIELD
9 +5V +5V
B> Output Port
1. PC Keyboard Output
DIN 5 MALE DIN 5 FEMALE
Pin No. Function Pin No. Function
1 HOST CLK 1 KB CLK
2 HOST DATA 2 KB DATA
4 GND 4 GND
5 Vcc(+5V) 5 Vcc(+5V)
MiniDIN 6 MALE MiniDIN 6 FEMALE
Pin No. Function Pin No. Function
1 HOST DATA 1 KB DATA
3 GND 3 GND
4 Vcc 4 Vcc
5 HOST CLK 5 KB CLK
45
3
2
1
5 4
1
2
3
3
1
5
4
2
6
3
1
5
4
2
6
1
69
5

7
6
15
9
12
43
1
3
2
4
6
7
8
5
21
3
4
2
5
1
3
8
7
6
4
6
1
5
9
2. RS-232 Output
DB 9 Female
Pin No. Function
2 TXD
3 RXD
5 GND
7 CTS
8 RTS
Power Lead Vcc (+5V)
3. WAND Emulation Output
DB 9 Female
Pin No. Function
2 DATA
7 GND
9 Vcc (+5V)
4. ADB Interface
MiniDIN 4 MALE MiniDIN 4 FEMALE
Pin No. Function Pin No. Function
1 ADB 1 ADB
3 Vcc 3 Vcc
4 GND 4 GND
5. NEC 9801 Interface
MiniDIN 8 MALE MiniDIN 8 FEMALE
Pin No. Function Pin No. Function
1 RST 1 RST
2 GND 3 GND
3 HOST RDY 4 KB RDY
4 HOST DATA 5 KB DATA
5 RTY 4 RTY
8 +5V 5 +5V

8
Chapter 2 Configuration - General
2.1 Flow Chart

10
%$ + / 0
%$ + / 1
%$ + / 2
%$ + / 3
%$ + / 4
%$ + / 6
%$ + / 5
2.4 Main Page of Configuration
Save Parameters
Recall Stored
Parameters
Set All Defaults
Start Configuration
End Configuration
Abort Configuration
Version Information
Save Parameters -
The parameter settings will be saved permanently.
Recall Stored Parameters -
Replace the current parameters by the parameters
you saved last time.
Set All Defaults -
Set all th e parameters to the factory default
settings.
Abort Configuration -
Terminate current programming status.
Version Information -
Display the decoder version information and date
code.

11
Chapter 3 Interface and
Reading Mode Selection
3.1 Interface Selection
<Keyboard Mode>
RS232 Mode
WAND Emulation
USB Mode
3.2 Memory Function<HC102M Only>
<Enable>
Disable
%0 0 U0
%0 0 U8
%0 0 M2
%0 XI 2
%0 XI 0
%0 XO8

12
3.3 Reading Mode Selection
<Good Read OFF>
Trigger ON/OFF
Continuous/Trigger OFF
Testing
Continuous/Auto Power On
Flash
Flash/Auto Power On
Reserved1
Reserved 2 ( Auto Sense
Option)
Reserved3
Reserved4
Reserved5
%02 7 1
%02 7 0
%02 7 2
%02 7 5
%02 7 3
%02 7 4
%02 7 6
%02 7 7
%0 9 F8
%0 9 F9
%0 9 FA
%0 9 FB

13
Ch.4 Communication Parameters
4.1 RS232 Communication Parameters
A> Set Up BAUD Rate
1200
2400
4800
<9600>
19200
38400
B> Set Up Data Bits
7 Data Bits
<8 Data Bits>
C> Set Up Stop Bits
<1 Bit>
2 Bits
%0 Y8 0
%0 Y8 8
%0 Y7 1
%0 Y7 2
%0 Y7 3
%0 Y7 7
%0 Y7 4
%0 YO8
%0 YO0
%0 Y7 5

14
D> Set Up Parity
<None>
Even
Odd
Mark
Space
E> Handshaking
RTS/CTS Enable
<RTS/CTS Disable>
ACK/NAK Enable
<ACK/NAK Disable>
XON/XOFF Enable
<XON/XOFF Disable>
%0 YN7
%0 YN2
%0 YN3
%0 YN1
%0 YN0
%0188
%0180
%0144
%0140
%0 3 K4
%0 3 K0

15
4.2 Keyboard Wedge Mode Parameters
A> Terminal Type
<IBM PC/AT, PS/2>
IBM PC/XT
IBM PS/2 25, 30
NEC 9800
Apple Desktop Bus( )ADB
IBM 5550
IBM 122 Key (1)
IBM 102 Key
IBM 122 Key (2)
Reserved 1
Reserved 2
Reserved 3
Reserved 4
Reserved 5
%0 Z F0
%0 Z F1
%0 Z F2
%0 Z F3
%0 Z F4
%0 Z F5
%0 Z F6
%0 Z F7
%0 Z F8
%0 Z F9
%0 Z FA
%0 Z FB
%0 Z FC
%0 Z FD

16
B> Upper/Lower Case
<No Change>
Upper Case
Lower Case
C> Capslock Detection
Enable
<Disable>
D> Send Character by ALT Method
Enable
<Disable>
E>Select Numerical Pad
ON
<OFF>
%0330
%0331
%0332
%0 X8 8
%0 X8 0
%0 3O8
%03 O0
%01 K4
%01 K0

17
4.3 Output Characters Parameters
A> Select Terminator
<CR+LF>
None
CR
LF
Space
HT(TAB)
STX-ETX
%7 S0 +
%7 S2 +
%7 S4 +
%7 S5 +
%7 S7 +
%7 S1 +
%7 S3 +

18
B> Time-out Between Characters
<0 ms>
5 ms
10 ms
25 ms
50 ms
100 ms
200 ms
300 ms
%0070
%0071
%0072
%0073
%0074
%0075
%0076
%0077

19
4.4 Wand Emulation Mode Parameters
A> TTL Level Representation
<Bar Equals High>
Bar Equals Low
B> Scan Speed Selection
<Fast>
Slow
C> Output Format Selection
<Output as Code 39>
Output as Code 39
Full ASCII
Output as Original
Code Format
%0 2 K4
%0 2 K0
%0288
%0280
%0 2 O8
%0 2 O0
%0 XK4

20
Ch.5 Bar Codes & Others
5.1 Symbologies Selection
UPC-A <ON>
OFF
UPC-E <ON>
OFF
EAN-13/JAN-13/ISBN-13
<ON>
OFF
EAN-8/JAN-8 <ON>
OFF
CODE 39 <ON>
OFF
CODE 128 <ON>
OFF
CODABAR/NW7 <ON>
OFF
%0 A4 4
%0 A4 0
%0 BO8
%0 BO0
%0 A2 2
%0 A2 0
%0 A1 1
%0 A1 0
%0 EO8
%0 EO0
%0 FO8
%0 FO0
%0 J O8
%0 J O0

21
Interleave 25 <ON>
OFF
Industrial 25 ON
<OFF>
Matrix 25 ON
<OFF>
CODE 93 ON
<OFF>
CODE 11 ON
<OFF>
China Postage ON
<OFF>
MSI/PLESSEY ON
<OFF>
%0 GO8
%0 GO0
%0 HO8
%0 HO0
%0 I O8
%0 I O0
%0 KO8
%0 KO0
%0 L O8
%0 L O0
%0 MO8
%0 MO0
%0 NO8
%0 NO0

23
%0 UO8
%0 UO0
%0 VO8
%0 VO0
%1 A/ +
%0 WO8
%0 WO0
GS1 DataBar Omnidirectional ON
<OFF>
GS1 DataBar Limited ON
<OFF>
GS1 DataBar Expanded ON
<OFF>
Select All Bar Codes

24
5.2 UPC/EAN/JAN Parameters
A> Reading Type
UPCA=EAN13 ON
UPCA=EAN13<OFF>
ISBN-10 Enable
ISBN-13 <Enable>
ISSN Enable
ISSN <Disable>
Decode with Supplement
<Autodiscriminate
Supplement>
Expand UPC-E
Enable
Expand UPC-E
<Disable>
EAN8=EAN13
Enable
EAN8=EAN13
<Disable>
GTIN Format
Enable
GTIN Format
<Disable>
%0 AK4
%0 AK0
%0 B8 8
%0 B8 0
%0 B4 4
%0 B4 0
%0 1 O0
%0 1 O8
%0BH1
%0BH0
%0AO0
%0X4 4
%0X4 0
%0AO8

25
B> Supplementals Set Up
<Not Transmit>
Transmit 2 Code
Transmit 5 Code
Transmit 2&5 Code
C> Check Digit Transmission
UPC-A Check Digit
Transmission <ON>
OFF
UPC-E Check Digit
Transmission <ON>
OFF
EAN-8 Check Digit
Transmission <ON>
OFF
EAN-13 Check Digit
Transmission <ON>
OFF
ISSN Check Digit
Transmission <ON>
OFF
%0 AI 2
%0 AI 0
%0 BI 2
%0 BI 0
%0 AH1
%0 AH0
%0 A8 8
%0 A8 0
%0 B3 3
%0 B3 1
%0 B3 2
%0 B3 0
%0 BK4
%0 BK0

26
5.3 Code 39 Parameters
A> Type of Code
<Standard>
Full ASCII
Italian Pharmacy/Code 32
<OFF>
Italian Pharmacy/
Code 32 ON
B> Check Digit Transmission
<Do Not Calculate
Check Digit>
Calculate Check Digit
& Transmit
Calculate Check Digit
& Not Transmit
C> Output Start/Stop Character
Enable
<Disable>
%0 EH1
%0 EH0
%0 E8 8
%0 E8 0
%0 EM2
%0 EM6
%0 EM4
%0 E4 4
%0 E4 0

28
5.4 Code 128 Parameters
A> Reading Type
UCC/EAN-128
Enable
<UCC/EAN-128
Disable>
<Enable']C1'Code
Format>
Disable']C1'Code
Format
<Enable Code128 Group
Separators (GS)>
Disable Code128
Group Separators
(GS)
B> Check Digit Transmission
Do Not Calculate
Check Digit
Calculate Check
Digit & Transmit
<Calculate Check Digit
& Not Transmit>
C> Append FNC2
ON
<OFF>
%0 F N7
%0 F N5
%0 F 8 8
%0 F 8 0
%0 F N1
%0 F 4 4
%0 F 4 0
%0 F 2 2
%0 F 2 0
%0 F 1 1
%0 F 1 0

30
5.5 Interleave 25 Parameters
A> Check Digit Transmission
<Do Not Calculate
Check Digit>
Calculate Check Digit
& Transmit
Calculate Check Digit
& Not Transmit
B> Set Up Number of Character
<Even>
Odd
C> Brazilian Banking Code
<Disable>
Enable
%0 GN3
%0 GN7
%0 GN5
%0 G8 8
%0 G8 0
%0 G4 0
%0 G4 4

31
D> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the length to be
read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%4 G1 +
%4 G0 0
%4 G0 1
%4 G0 0
%4 G0 2
%2 + - /
%2 C2 +

33
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%4 H1 +
%4 H0 0
%4 H0 0
%4 H0 1
%4 H0 2
%2 + - /
%2 C3 +

34
5.7 Matrix 25 Parameters
A> Check Digit Transmission
<Do Not Calculate
Check Digit>
Calculate Check Digit
& Transmit
Calculate Check Digit
& Not Transmit
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the length to be
read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%0 I N3
%0 I N7
%0 I N5

35
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%4 I 1 +
%4 I 0 0
%4 I 0 0
%4 I 0 1
%4 I 0 2
%2 + - /
%2 C4 +

36
5.8 CODABAR/NW7 Parameters
A> Set Up Start/Stop Characters Upon
Transmission
ON
<OFF>
B> Transmission Type of Start/Stop
<A/B/C/D> <Start>
<A/B/C/D> <Stop>
A Start
A Stop
B Start
B Stop
C Start
C Stop
D Start
D Stop
%0 J H1
%0 J H0
%0 4 VF
%0 4 F F
%0 4 V1
%0 4 F 1
%0 4 V2
%0 4 F 2
%0 4 V4
%0 4 F 4
%0 4 V8
%0 4 F 8

37
C> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the length to be
read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%4 J 1 +
%4 J 0 0
%4 J 0 0
%4 J 0 1
%4 J 0 2
%2 + - /
%2 C5 +

38
5.9 Code 93 Parameters
A> Check Digit Transmission
<Calculate Check 2 Digits
& Not Transmit>
Do Not Calculate
Check Digit
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the length to be
read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%0 KN3
%0 KN4

39
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%4 K1 +
%4 K0 0
%4 K0 0
%4 K0 1
%4 K0 2
%2 + - /
%2 C6 +

40
5.10 Code 11 Parameters
A> Check Digit Transmission
<Do Not Calculate
Check Digit>
Calculate Check 1
Digit & Transmit
Calculate Check 1 Digit
& Not Transmit
Calculate Check 2
Digits & Transmit
Calculate Check 2 Digits
& Not Transmit
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the length to be
read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%0 L N3
%0 L N7
%0 L N5
%0 L N6
%0 L N4

41
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%4 L 1 +
%4 L 0 0
%4 L 0 0
%4 L 0 1
%4 L 0 2
%2 + - /
%2 C7 +

42
5.11 MSI/PLESSEY Code Parameters
A> Check Digit Transmission
Do Not Calculate
Check Digit
Calculate Check Digit
& Transmit
<Calculate Check Digit
& Not Transmit>
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the length to be
read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%0 NN3
%0 NN7
%0 NN5

43
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%4 N1 +
%4 N0 0
%4 N0 0
%4 N0 1
%4 N0 2
%2 + - /
%2 C9 +

44
5.12 Code 2 of 6 Parameters
A> Check Digit Transmission
<Do Not Calculate
Check Digit>
Calculate Check
Digit & Transmit>
Calculate Check Digit
& Not Transmit
B> Set Up Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the length to be
read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%0 PN3
%0 PN7
%0 PN5

45
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2nd Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%2 + - /
%4 P1 +
%4 P0 0
%4 P0 1
%4 P0 0
%4 P0 2
%2 CB+

46
5.13 LCD25 Parameters
A> Check Digit Transmission
<Do Not Calculate
Check Digit>
Calculate Check Digit
& Transmit
Calculate Check
Digit & Not Transmit
B> Setup Code Length
To set the fixed length:
1. Scan the "Begin" label of the desired set.
2. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the length to be
read.
3. Scan the "Complete" label of the desired set.
Repeat the steps 1 - 3 to set additional lengths.
%0 QN3
%0 QN7
%0 QN5

47
<Variable>
Fix Length (2 Sets Available)
1. 1st Set Begin 2. Decimal Value
(Appendix A)
3. 1st Set Complete
1. 2st Set Begin 2. Decimal Value
(Appendix A)
3. 2nd Set Complete
Minimum Length
1. Begin 2. Decimal Value
(Appendix A)
3. Complete
%2 + - /
%4 Q1 +
%4 Q0 0
%4 Q0 1
%4 Q0 0
%4 Q0 2
%2 CC+

52
Ch.6 Miscellaneous Parameters
6.1 Language Selection
<US English>
UK English
Italian
Spanish
French
German
Swedish
Switzerland
Hungarian
Japanese
%0 ZV0
%0 ZV1
%0 ZV2
%0 ZV3
%0 ZV4
%0 ZV5
%0 ZV6
%0 ZV7
%0 ZV8
%0 ZV9

53
Belgium
Portuguese
Denmark
Netherlands
Turkey
Reserved2
%0 ZVA
%0 ZVB
%0 ZVC
%0 ZVD
%0 ZVE
%0 ZVF

54
6.2 Bar Code ID
ON
<OFF>
Default
With this function ON, a leading character will be
added to the output string while scanning code, user
may refer to the following table to know what kind of
bar code is being scanned.
Please refer to the table below for matching code
ID of codes read in.
Code Type ID Code Type ID
UPC-A A UPC-E B
EAN-8 C EAN-13 D
CODE 39 E CODE 128 F
Interleave 25 G Industrial 25 H
Matrix 25 I Codabar/NW7 J
CODE 93 K CODE 11 L
China Postage M MSI/PLESSEY N
Code 2 of 6 P LCD25 Q
Telepen T RSS-14 U
RSS Limited V RSS Expanded W
User Define Code ID
To set the code ID:
1. Scan the symbologies label.
2. Go to the ASCII Tables in Appendix B, scan
label that represents the desired code ID.
Note:
User define code ID will override default value.
Program will not check the conflict. It is possible
to have more than two symbologies which have
same code ID.
%0 0 H1
%0 0 H0
%913+

55
UPC-A
UPC-E
EAN-13/JAN-13
EAN-8/JAN-8
CODE 39
CODE 128
CODABAR/NW7
Interleave 25
Industrial 25
Matrix 25
CODE 93
CODE 11
China Postage
MSI/PLESSEY
%9 1 A+
%9 1 B+
%9 1 Y+
%9 1 Z+
%9 1 E+
%9 1 F+
%9 1 G+
%9 1 H+
%9 1 I +
%9 1 J +
%9 1 K+
%91L+
%9 1 M+
%9 1 N+

57
6.3 Reading Level
Bar Equals High
<Bar Equals Low>
6.4 Accuracy
<1 Time>
2 Times
3 Times
4 Times
6.5 Buzzer Beep Tone
<High>
Medium
Low
Off
6.6 LED Control(SV700 only)
<ON>
OFF
%0130
%0131
%0132
%0133
%0 1 J 3
%0 1 J 2
%0 1 J 1
%0 1 J 0
%0 3 I 0
%0 3 I 2
%09 O8
%09 O0

58
6.7 Sensitivity of Continuous Reading Mode
A> Quick Setting:
<Fast>
Slow
B> Same Code Delay Reading Interval
Following code sequences represent the
length of time before a barcode can be
rescanned at continuous and flash reading
mode. The value can be defined from 1-50
and they represent 100ms to 5 seconds in
100ms interval.Default value is 3 (0.3 seconds).
To setup same code delay reading interval:
1.Scan the "Begin" label
2.Go the Decimal Value Tables in Appendix A,
Scan label(s),that represents the same code
delay reading interval.They are ranged form
1-50.One step is represented 0.1second.So
the interval is from 0.1 to 5 seconds.
3.Scan the "Complete" label
Repeat the steps 1-3 to set time out of same
symbol
1.Begin 2.Decimal Value
(1-50) (Appendix A)
3.Complete
6.8 Notebook Function
Enable
<Disable>
%0 3 8 8
%0 3 8 0
%0 3 4 4
%0 3 4 0
%3 0 0 0 0
%3 0 0 0 1

59
6.9 Reverse Output Characters
<Disable>
%0 3 H0
Enable
6.10 Setup Deletion
To setup the deletion of output characters:
1. Scan the label of the desired set below.
2. Scan the label of the desired symbology.
3. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the desired
position to be deleted.
4. Scan the "Complete" label of "Character Position
to be Deleted".
5. Go to the Decimal Value Tables in Appendix A,
scan label(s) that represents the number of
characters to be deleted.
6. Scan the "Complete" label of "Number of
Characters to be Deleted".
Repeat the steps 1 - 6 to set additional deletion.
A> Select Deletion Set Number
1. 1st Set
2. 2nd Set
3. 3rd Set
4. 4th Set
5. 5th Set
6. 6th Set
%8 0 0 +
%8 0 1 +
%8 0 2 +
%8 0 3 +
%8 0 4 +
%8 0 5 +
%0 3 H1

60
B> Symbologies Selection
UPC-A
UPC-E
EAN-13/JAN-13/ISBN-13
EAN-8/JAN-8
CODE 39
CODE 128
CODABAR/NW7
Interleave 25
Industrial 25
Matrix 25
CODE 93
CODE 11
China Postage
MSI/PLESSEY
%8 1 A+
%8 1 B+
%8 1 Y+
%8 1 Z +
%8 1 E+
%8 1 F +
%8 1 J +
%8 1 G+
%8 1 H+
%8 1 I +
%8 1 K+
%8 1 L +
%8 1 M+
%8 1 N+

61
Code 2 of 6
Telepen
LCD25
RSS-14
RSS Limited
RSS Expanded
All Codes
None
C> Character Position to be Deleted
1. Decimal Value
(Appendix A) 2. Complete
D> Number of Characters to be Deleted
1. Decimal Value
(Appendix A) 2. Complete
%8 1 P+
%8 1 S+
%8 2 0 +
%8 3 0 +
%8 1 4 +
%8 1 T+
%8 1 Q+
%8 1 U+
%8 1 V+
%8 1 W+


63
B> Symbologies Selection
UPC-A
UPC-E
EAN-13/JAN-13/ISBN-13
EAN-8/JAN-8
CODE 39
CODE 128
CODABAR/NW7
Interleave 25
Industrial 25
Matrix 25
CODE 93
CODE 11
China Postage
MSI/PLESSEY
%5 1 A+
%5 1 B+
%5 1 Y+
%5 1 Z +
%5 1 E+
%5 1 F +
%5 1 G+
%5 1 J +
%5 1 H+
%5 1 I +
%5 1 K+
%5 1 L +
%5 1 M+
%5 1 N+

64
Code 2 of 6
Telepen
LCD25
RSS-14
RSS Limited
RSS Expanded
All Codes
None
C> Character Position to be Inserted
1. Decimal Value
(Appendix A) 2. Complete
D> Characters to be Inserted
1. ASCII Table
(Appendix B) 2. Complete
%5 2 0 +
%5 3 0 +
%5 1 4 +
%5 1 S+
%5 1 P+
%5 1 T+
%5 1 Q+
%5 1 U+
%5 1 V+
%5 1 W+

65
6.12 Setup IR Sensor (LG303 only)
<Disable>
Enable
%0 XH0
%0 XH1
Produktspecifikationer
Varumärke: | Manhattan |
Kategori: | Streckkodsläsare |
Modell: | 460835 |
Behöver du hjälp?
Om du behöver hjälp med Manhattan 460835 ställ en fråga nedan och andra användare kommer att svara dig
Streckkodsläsare Manhattan Manualer

9 Oktober 2024

24 September 2024

1 September 2024

31 Augusti 2024

31 Augusti 2024

30 Augusti 2024

29 Augusti 2024

29 Augusti 2024

27 Augusti 2024

26 Augusti 2024
Streckkodsläsare Manualer
- Streckkodsläsare Casio
- Streckkodsläsare Honeywell
- Streckkodsläsare Motorola
- Streckkodsläsare Nedis
- Streckkodsläsare Renkforce
- Streckkodsläsare Nilox
- Streckkodsläsare DeLock
- Streckkodsläsare Steren
- Streckkodsläsare Argox
- Streckkodsläsare IFM
- Streckkodsläsare Digitus
- Streckkodsläsare Olympia
- Streckkodsläsare Deltaco
- Streckkodsläsare Konig
- Streckkodsläsare Intermec
- Streckkodsläsare Zebra
- Streckkodsläsare Palm
- Streckkodsläsare Datalogic
- Streckkodsläsare GoDEX
- Streckkodsläsare Adesso
- Streckkodsläsare POSline
- Streckkodsläsare M3 Mobile
- Streckkodsläsare ELO
- Streckkodsläsare Brady
- Streckkodsläsare Baracoda
- Streckkodsläsare Posiflex
- Streckkodsläsare Datamax-O'neil
- Streckkodsläsare CipherLab
- Streckkodsläsare Trimble
- Streckkodsläsare Cypress
- Streckkodsläsare Newland
- Streckkodsläsare DENSO
- Streckkodsläsare Socket Mobile
- Streckkodsläsare QUIO
- Streckkodsläsare EC Line
- Streckkodsläsare Tecno
- Streckkodsläsare ZBA
- Streckkodsläsare Code Corporation
- Streckkodsläsare Hamlet
- Streckkodsläsare Qoltec
- Streckkodsläsare Approx
- Streckkodsläsare Wasp
- Streckkodsläsare Vultech
- Streckkodsläsare Mach Power
- Streckkodsläsare Psion
- Streckkodsläsare Koamtac
- Streckkodsläsare Unitech
- Streckkodsläsare Opticon
- Streckkodsläsare Atlantis Land
- Streckkodsläsare ID-Tech
- Streckkodsläsare Code
- Streckkodsläsare Qian
- Streckkodsläsare Bluebird
- Streckkodsläsare Cognex
Nyaste Streckkodsläsare Manualer

2 April 2025

2 April 2025

1 April 2025

27 Februari 2025

27 Februari 2025

27 Februari 2025

25 Februari 2025

23 Februari 2025

21 Februari 2025

21 Februari 2025