For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 2
INSTALLATION INSTRUCTIONS
© Panduit Corp. 2020
PN376E
Bulkhead w/
Nut
Coupler
Tether w/
Cap
Module
Face Seal
Bulkhead
Seal
IndustrialNet
TM
Bulkhead Couplers
Part Number: IAEBHC6, IAEBHC6XS, IAEBHC5E, IAEBHC5ES
3
(Enclosure wall removed for clarity)
1
2
Bulkhead Opening Requirements
Ø 1-13/64"
(30.6mm)
1-7/8"
(47.6mm)
1-7/8"
(47.6mm)
Enclosure Wall
Insert Bulkhead into prepared opening from outside of
enclosure. While holding Bulkhead in place, secure with Nut on inside of
enclosure. Hand turn Nut 4-1/4 to 5 full turns. Be careful not to tighten to
the point the Bulkhead Seal is over compressed and displaced from the
enclosure wall and the Bulkhead.
Note: If using wrench, flats on Nut should be on the outside.
Inside of EnclosureOutside of Enclosure
or Outlet Plate
Min. thickness: 0.035" (20 gauge)
Max. thickness: 0.135" (10 gauge)
Bulkhead
Seal
{not to scale}
Produktspecifikationer
| Varumärke: | Panduit |
| Kategori: | ej kategoriserat |
| Modell: | IAEBHC6 |
| Produktens färg: | Grön |
| Antal per förpackning: | 1 styck |
| Hållbarhetscertifiering: | RoHS |
| Anslutning: | RJ-45 |
| Kabelskärmen: | U/UTP (UTP) |
| Kabel standard: | Cat6 |