Läs gratis den bruksanvisning för ResMed Hospital Nasal Mask (33 sidor) i kategorin ej kategoriserat. Guiden har ansetts hjälpsam av 2 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 1.5 recensioner. Har du en fråga om ResMed Hospital Nasal Mask eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/33

ENGLISH
The RESMED HOSPITAL
NASAL MASK is intended for single patient use for adult patients
(>30 kg) prescribed continuous positive airway pressure or bilevel therapy in hospitals or
clinics.
This is a disposable mask. It is intended to be used fo
r the short-term (7 days) treatment of
a single patient only, then discarded.
MEDICAL INFORMATION
Note: The mask system does not contain latex materials. If the patient has ANY reaction to any
part of the mask system, discontinue use.
WARNINGS
• This mask should be used only with CPAP or bilevel systems recommended by a
physician or respiratory therapist. A mask should not be used unless the CPAP or bilevel
system is turned on and operating properly.
Explanation of the Warning: CPAP or bilevel syst
ems are intended to be used with
special masks with connectors which have vent holes or separate exhalation devices to
allow continuous flow of air out of the mask. When the CPAP or bilevel device is turned
on and functioning properly, new air from the flow generator flushes the exhaled air out
through the mask exhalation port. However, when the CPAP or bilevel device is not
operating, enough fresh air may not be provided through the mask, and exhaled air may
be rebreathed. Rebreathing of exhaled air for longer than several minutes can in some
circumstances lead to suffocation. This warning applies to most models of CPAP or
bilevel systems.
• The exhaust vent flow is lower at lower mask pressures (see Pressure/Flow curve). If the
mask pressure during expiration is too low, there may not be enough exhaust vent flow
to completely flush the air delivery hose of exhaled air before the start of the next
inspiration.
• If oxygen is used with the CPAP or bilevel device, the oxygen flow must be turned off
when the flow generator is not operating.
Explanation of the Warning: When the CPAP or bilevel device is not in operation, and
ResMed Hospital Nasal Mask
USER’S GUIDE

the oxygen flow is left on, oxygen delivered into the ventilator tubing may accumulate
within the flow generator enclosure. Oxygen accumulated in the CPAP or bilevel device
enclosure will create a risk of fire. This warning applies to most types of CPAP or bilevel
flow generators.
• Please refrain from smoking while oxygen is in use.
• Using a mask may cause tooth, gum or jaw soreness or aggravate an existing dental
condition. If symptoms occur, consult your physician or dentist.
Note: At a fixed rate of supplemental oxygen flow,
the inhaled oxygen concentration will vary,
depending on the pressure settings, patient breathing pattern, mask selection, and leak rate.
FITTING THE MASK
The RESMED HOSPITAL NASAL MASK is supplied fully assembled.
1 Connect one end of the main air tubing to the flow generator and the other end to the
swivel. Turn the flow generator on. See “Technical Specifications” for information on
which flow generator setting to use.
2 P
lace the mask cushion over the patient’s nose
and pull the headgear over their head.
3 Unfasten and gently tighten the headgear straps to achieve a secure and comfortable fit.
Ad
just the top strap first. Then adjust the side straps, making sure that they pass below
the patient’s ears. Do not overtighten the straps.
4 The fitted mask
should look like this:
headgear
top strap
side strap
mask
swivel
elbow
5 If the patient feels air leaks around the cushion, reposition the mask on the patient’s nose
to achieve a better seal. You may also need to readjust the headgear straps.
REMOVING THE MASK
To remove the RESMED HOSPITAL
NASAL MASK, unfasten one of the side headgear straps
and pull the mask and headgear up over the patient’s head.
Produktspecifikationer
Varumärke: | ResMed |
Kategori: | ej kategoriserat |
Modell: | Hospital Nasal Mask |
Behöver du hjälp?
Om du behöver hjälp med ResMed Hospital Nasal Mask ställ en fråga nedan och andra användare kommer att svara dig
ej kategoriserat ResMed Manualer
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
ej kategoriserat Manualer
- Anex
- Adder
- Vello
- Hillvert
- Reloop
- Noordi
- Godox
- Victron Energy
- Amaran
- Bredeco
- Yamazen
- Cuisinart
- Genaray
- XPG
- DOCtron
Nyaste ej kategoriserat Manualer
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025
29 Augusti 2025