Sanwa PC700 Bruksanvisning
Sanwa
Multimeter
PC700
Läs gratis den bruksanvisning för Sanwa PC700 (31 sidor) i kategorin Multimeter. Guiden har ansetts hjälpsam av 23 personer och har ett genomsnittsbetyg på 4.3 stjärnor baserat på 12 recensioner. Har du en fråga om Sanwa PC700 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/31

PC700
DIGITAL MULTIMETER
INSTRUCTION MANUAL

Table of Contents
[1] SAFETY PRECAUTIONS
1-1 Explanation of Warning Symbols
1-2 Warning Instructions for Safe Use
1-3 Overload Protection
[2] APPLICATIONS AND FEATURES
2-1 Applications
2-2 Features
[3] Parts Identification
3-1 Multimeter and Test Leads
3-2 Display
[4] DESCRIPTION OF FUNCTIONS
4-1 Power Switch/Function Selector
4-2 Auto Power Saving
4-3 Low Battery Indication
4-4 Measuring Function Selection
4-5 Range Hold
4-6
Data Hold
4-7 Beeper Control
4-8 PC (Personal Computer) Interface
4-9 Test Leads Improper Connection Warning
4-10
Relative Measurement
4-11 Terms
[5] Measuring procedures
5-1 Pre-operational Check
5-2 AC Voltage (
) / Frequency (Hz) Measurement
5-3 DC/AC Voltage (V) Measurement
5-4 DC/AC Voltage ( mV ) , Logic-Level Frequency (
Hz) and
Duty Cycle (
D%) Measurement
5-5 AC Voltage ( m
) / Frequency (Hz) Measurement
5-6 Resistance(Ω)Measurement
5-7 Continuity Check (
)
5-8 Capacitance (
) Measurement, Diode ( ) Test
5-9 DC/AC Current (A), AC Current (m
,μ
,
)/ Frequency
(Hz) Measurement
5-10 Measurements with Separately Available Accessories
[6] MAINTENANCE
6-1 Simple Examination
6-2 Calibration
6-3 Battery and Fuse Replacement
6-4 Storage
[7] AFTER-SALE SERVICE
7-1 Warranty and Provision
7-2 Repair
7-3 SANWA web site
[8] SPECIFICATIONS
8-1 General Specifications
8-2 Measuring Range and Accuracy
1
2
3
4
4
5
7
8
8
9
9
10
10
10
11
12
12
12
14
16
19
21
24
26
28
30
34
40
44
44
45
46
47
47
48
49
51
●● Messages●on●the●display
Messages Description What to do
InEr
Test leads improper connection warning
(Malfunction when low battery)
See 4-9 (Page 12)
See 4-3 (Page 9)
rE-O
Self-diagnostic See 6-2 (Page 44)
C_Er

― 2 ―― 1 ―
1-2 Warning Instructions for Safe Use
1. Do not use the instrument if the meter or test leads look
damaged.
2. Be sure to use the specified fuse.
Neither use unspecified fuse nor short-circuit the fuse holder.
3. Do not apply higher voltage or current than the max. ratings
by each function. (See 1-3)
4. Use caution when working with voltages above 33 V ac rms,
46.7 V ac peak, or 70 V dc. These voltages pose a shock
hazard.
5. Do not use the meter to measure lines that may have
inductive voltage or surge voltage (e.g. motors) because the
input voltage may exceed the maximum rated voltage.
6. Never operate the meter with the case or battery lid removed.
7. Remove test leads from the meter before opening the meter
case for replacing the battery or fuse.
8. Never attempt to repair or modify the instrument, except for
battery and fuse replacement.
9. Do not use any unspecified type of test leads.
10. Keep your fingers behind the finger guards of the test leads
while measurement.
11. Connect the common test lead (Black) before you connect
the live test lead (Red). Disconnect the live test lead first.
12. Make sure the function, range, and terminals are properly set.
13. Do not switch the function, range, or the plugs to another
while measurement.
14. Do not operate the meter when it is wet or with wet hands.
WARNING
Incorrect measurement may be performed in a ferromagnetic or
intense electric field near transformers, high-current circuits, and
radio equipments.
CAUTION
[1] SAFETY PRECAUTIONS
*Before use, read the following safety precautions.
This instruction manual explains how to use your digital multimeter
PC700. Before using, read through this manual to reduce the risk
of fire , electric shock, and/or injury. And save it together with the
product so that you can refer to the manual as necessary.
Use the instrument only as specified in this manual or the protection
provided by the instrument may be impaired.
The instructions given under the headings of "
WARNING" and
must be followed to prevent accidental burn andelectric shock.
1-1 Explanation of Warning Symbols
The meanings of the symbols used in this manual and attached to
the product are as follows.
:Extremely-important instructions for safe use
・
WARNING identifies conditions and actions that could result in
accidental burn and electric shock.
・
CAUTION identifies conditions and actions that could cause
damage the instrument.
:Do not touch! Possible high voltage.
:Ground :Diode Hz:Frequency
:Fuse :Beep
:
Logic-Level Frequency
:
Direct Current(DC)
:Capacitor :Duty Cycle
:Alternate Current (AC)
:
Resistance
:
Double Insulation or Reinforced
Produktspecifikationer
Varumärke: | Sanwa |
Kategori: | Multimeter |
Modell: | PC700 |
Behöver du hjälp?
Om du behöver hjälp med Sanwa PC700 ställ en fråga nedan och andra användare kommer att svara dig
Multimeter Sanwa Manualer
10 September 2025
27 Augusti 2025
27 Augusti 2025
26 Augusti 2025
26 Augusti 2025
8 December 2024
18 September 2024
18 September 2024
18 September 2024
18 September 2024
Multimeter Manualer
- Flir
- Metrix
- Noyafa
- Silverline
- Qian
- Fluke
- TFA
- Dasqua
- Weidmüller
- Ferm
- Brandson
- Kewtech
- Digi-tool
- Ideal
- Vemer
Nyaste Multimeter Manualer
12 September 2025
12 September 2025
11 September 2025
11 September 2025
10 September 2025
10 September 2025
10 September 2025
10 September 2025
7 September 2025
1 September 2025