Klein Tools CL1200 Bruksanvisning


Läs gratis den bruksanvisning för Klein Tools CL1200 (8 sidor) i kategorin mätning. Guiden har ansetts hjälpsam av 25 personer och har ett genomsnittsbetyg på 4.2 stjärnor baserat på 8 recensioner. Har du en fråga om Klein Tools CL1200 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/8
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street
Lincolnshire, IL 60069
1-877-775-5346
www.kleintools.com
139701 Rev. 01/14 B
ENGLISH
DATA HOLD
BACKLIGHT
WORKLIGHT
ANALOG
BAR GRAPH
MAX/ MIN
3-5/6 DIGIT
5999 COUNT LCD
AUTO / MANUAL
RANGE
NON CONTACT
VOLTAGE TESTER
1200
ENGLISH
SYMBOLS USED ON LCD
~
AC MeasurementDC Measurement
-
Negative DC Value
AT
Auto Range Active
O
.L.
Overload: Range Exceeded
Apo
Auto Power-Off Active
Low Battery
HOLD
Hold Active
MIN
Minimum Reading
M
AX
Maximum Reading
%
Duty Cycle ModeFrequency Mode
V
Voltage Measurement
A
Current in Amps
Ω
Resistance in OhmsDiode Test
F
Capacitance in FaradsContinuity Test
n
Nano 10
-9
µ
Micro 10
-6
m
Milli 10
-3
k
Kilo 10
3
M
Mega 10
6
1200
1200
PRESS
and
HOLD
PRESS
and
HOLD
WARRANTY
www.kleintools.com/warranty
CLEANING
Turn instrument off and disconnect test leads. Clean the instrument by using
a damp cloth. Do not use abrasive cleaners or solvents.
STORAGE
Remove the batteries when instrument is not in use for a prolonged period of
time. Do not expose to high temperatures or humidity. After a period of storage
in extreme conditions exceeding the limits mentioned in the Specifications
section, allow the instrument to return to normal operating conditions before
using it.
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items
must be properly disposed of in accordance with local regulations.
8. Non Contact Voltage (NCV): > 25V AC
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
RangeResolutionAccuracy
600mV
˜
600V
0.1mV
˜
100mV
± (0.5% + 4 digits)
1000V1V± (0.8% + 10 digits)
Overload Protection: 1000V
AC Voltage Measurement
RangeResolutionAccuracy
600mV
˜
750V0.1mV
˜
1V± (2.0% + 5 digits)
Overload Protection: 750V RMS
Frequency Response: 45 to 400 Hz
Minimum Voltage for Frequency Measurement: 200mV
Response: Averaging
DC Current Measurement
RangeResolutionAccuracy
600µA0.1µA
± (1.2% + 3 digits)
2000µA1µA
Overload Protection:
Voltage: 600V RMS
Current (leads): 2000µA
AC Current Measurement
RangeResolutionAccuracy
600µA0.1µA± (2.0% + 5 digits)
2000µA1µA± (1.5% + 5 digits)
60A0.01A± (2.9% + 15 digits)
600A0.1A± (1.9% + 8 digits)
Overload Protection:
Voltage: 600V RMS
Current: (leads) 2000µA (clamp) 600A
Frequency: 45 to 400Hz
Minimum Current for Frequency Measurement: 400µA or 20A
Minimum Current for Clamp Measurement: 0.2A
Response: Averaging
Resistance Measurement
RangeResolutionAccuracy
600
Ω
˜
6MΩ0.1Ω
˜
1kΩ
± (1.0% + 4 digits)
60M
Ω10kΩ
± (2.0% + 4 digits)
Overload Protection: 600V RMS
Capacitance Measurement
RangeResolutionAccuracy
60nF
˜
6000µF0.01nF
˜
1µF± (3.5% + 6 digits)
Overload Protection: 600V RMS
Frequency Measurement (Voltage)
RangeResolutionAccuracy
99.99Hz
˜
499.9kHz0.01Hz
˜
100Hz± (0.1% + 4 digits)
Overload Protection: 600V RMS Sensitivity: 2.5V RMS
Duty Cycle Measurement
RangeResolutionAccuracy
1
˜
99%0.1%± (0.1% + 5 digits)
Overload Protection: 600V RMS Sensitivity: 1.2Vpp ~ 50Vpp
Frequency Range: < 500 Hz
Diode Test
Overload ProtectionRangeTest CurrentOpen Circuit Voltage
600V RMS
6.0VAppx. 0.25mA
<
1.8V DC
Continuity Test
Overload ProtectionOpen Circuit VoltageThreshold (Appx.)
600V RMS
<
0.44V
<40Ω
Non Contact Voltage Detector
On Voltage
Appx. 25V AC
Specifications subject to change.
750V
1000V
600A
Dwg Name:CL1200-139701ART Dwg No:139701
ECO No:15773 Pkg Dwg Ref:1650Rev: B
Color Reference:N/A
Instruction Manual
CL1200
CL1200 Instruction Manuals - MASTER.indd 1-41/30/2014 3:34:26 PM

Betygsätt denna manual

4.2/5 (8 Recensioner)

Produktspecifikationer

Varumärke: Klein Tools
Kategori: mätning
Modell: CL1200

Behöver du hjälp?

Om du behöver hjälp med Klein Tools CL1200 ställ en fråga nedan och andra användare kommer att svara dig