Läs gratis den bruksanvisning för Optex AX-100TF (14 sidor) i kategorin ej kategoriserat. Guiden har ansetts hjälpsam av 17 personer och har ett genomsnittsbetyg på 4.8 stjärnor baserat på 9 recensioner. Har du en fråga om Optex AX-100TF eller vill du ställa frågor till andra användare av produkten? Ställ en fråga
Sida 1/14

PHOTOELECTRIC DETECTOR
PHOTOELECTRIC DETECTOR
CONTENTS
1 INTRODUCTION
1-1 BEFORE YOUR OPERATION ............................... 2
1-2 PRECAUTIONS...................................................... 3
2 PARTS IDENTIFICATION............................................ 3
3 INSTALLATION
3-1 NOTE...................................................................... 4
3-2 INSTALLATION METHOD .................................... 4
4 WIRE CONNECTION................................................... 6
5 ALIGNMENT
5-1 OPTICAL ALIGNMENT .......................................... 7
5-2 BEAM INTERRUPTION TIME................................ 8
5-3 SELECTABLE BEAM FREQUENCIES
< AX-100/200TF ONLY >....................................... 8
6 WALK TEST................................................................. 9
7 SPECIAL FUNCTION < AX-100/200TF ONLY >
7-1 ENVIRONMENTAL DISQUALIFICATION .............. 9
7-2 ALARM MEMORY .................................................. 9
8 OPTIONAL ACCESSORIES
8-1 HEATING UNIT : HU-3......................................... 10
8-2 BACK COVER : BC-3........................................... 11
8-3 POLE SIDE COVER : PSC-3 ............................... 11
9 TROUBLESHOOTING............................................... 12
10
SPECIFICATIONS
10-1 SPECIFICATIONS.............................................. 13
10-2 DIMENSIONS & OPTION................................... 14
INSTALLATION INSTRUCTIONS
FEATURES
No.59-2419-2 2111-29
No.59-1282-7 0904-30
AX-70TN, AX-130TN, AX-200TN
AX-100TF, AX-200TF
< AX-70/130/200TN, AX-100/200TF >
•High-performance waterproof structure
•Horizontal alignment dial for user-friendliness
•Adjustable beam interruption period
•Tamper function
•
Optional Accessories : Heating unit (HU-3), Back cover (BC-3),
Pole side cover (PSC-3)
•UL Listed
< AX-100/200TF ONLY >
•4 selectable beam frequencies
•LED indicator for fine beam alignment level
•D.Q. circuit (Environmental disqualification)
•Alarm memory
AX-200TN 60 m / 200 ft.
30 m / 100 ft.
4 selectable beam
frequencies
60 m / 200 ft.
AX-100TF
AX-200TF
Model Detection range Feature
20 m / 70 ft.
40 m / 130 ft.
Standard model with
detection range
60 m / 200 ft.
AX-70TN
AX-130TN
UL
AX-70TN, AX-130TN, AX-200TN
AX-100TF, AX-200TF
EN
Multilingual instructions
Visit to the Web site to find
valious language versions.
https://navi.optex.net/manual/08401/
- 1 -
Produktspecifikationer
| Varumärke: | Optex |
| Kategori: | ej kategoriserat |
| Modell: | AX-100TF |
Behöver du hjälp?
Om du behöver hjälp med Optex AX-100TF ställ en fråga nedan och andra användare kommer att svara dig
ej kategoriserat Optex Manualer
6 Oktober 2025
9 September 2025
4 September 2025
3 September 2025
3 September 2025
3 September 2025
3 September 2025
3 September 2025
3 September 2025
3 September 2025
ej kategoriserat Manualer
- Falmec
- CYP
- Skil
- Gentrax
- Dynacord
- Elbe
- Genaray
- GoldAir
- AOC
- Chief
- Digitus
- Surebonder
- Waterpik
- Osprey
- Dimplex
Nyaste ej kategoriserat Manualer
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025
23 Oktober 2025