Heatit S-Control2 Bruksanvisning

Heatit Termostat S-Control2

Läs gratis den bruksanvisning för Heatit S-Control2 (2 sidor) i kategorin Termostat. Guiden har ansetts hjälpsam av 19 personer och har ett genomsnittsbetyg på 4.7 stjärnor baserat på 10 recensioner. Har du en fråga om Heatit S-Control2 eller vill du ställa frågor till andra användare av produkten? Ställ en fråga

Sida 1/2
Heatit Controls Heatit Controls AS l Mattisrudsvingen 19, 2827 Hunndalen, NORWAY
Phone: +47 61 18 77 77 l post@heatit.com – www.heatit.com
Do not dispose of electrical appliances as unsorted municipal waste,
use separate collection facilities. To prevent possible harm to the
environment or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the return and
collection systems or contact the retailer where the product was
We develop and design our products in accordance with our strict quality
requirements (ISO 9001) and environmental requirements (ISO 14001). All electrical
installations must be carried out by an authorized electrical installer. The product
must be installed in accordance with our installers manual and national building
codes. Any wrongful installation, misuse, damage of the product, is not covered
under warranty. Updated documentation is available at www.heatit.com and/or
documents.heatit.com. Heatit Controls AS can not be held liable for any type of
errors or omittances in our product information. Product specifications may change
without further notice.
Electrical Load Compatibility
The thermostat is designed specifically for resistive loads.
When controlling large resistive, capacitive, or inductive loads,
it is essential to use an appropriate contactor to protect the
thermostat from excessive load to ensure safe operation.
The thermostat can withstand a resistive load of up to
16A/3600W at 230VAC. For loads above 13A, we recommend
using a contactor.
INSTALLATION DISCLAIMER
Installation must be done by a qualified electrician in
accordance with national building codes. Before installation,
disconnect the power to the device from the mains. During
installation of the device, power to the device must be
disconnected AT ALL TIMES!
QUICK START
1. Switch o the mains voltage (turn o the fuse).
2. Open the junction box.
3. Connect according to the diagram as shown in
Chapter “Connections”.
4. After verifying the connections, switch on the mains voltage.
CONNECTIONS
Max tightening torque terminal screws: 2Nm.
If the cable used has multiple strands, using an end sleeve is
advised. The product allows for wiring of cables with a cross
section of up to 1x2.5mm.
Remove the rotary wheel and use a screwdriver to compress
the fastening clips on the sides to remove the front from the
back piece.
Floor sensor NTC type 10kΩ.
External sensor NTC type 10kΩ.
N Power connection (Neutral) 230VAC.
No Heating cable No connection.
L Power connection (Live) 230VAC.
Lo Heating cable Lo connection.
INTRODUCTION
Heatit S-Control2 is an electronic thermostat designed for
water-based and electrical heating control. With four functions,
it oers safe and reliable heating control. The thermostat
provides accurate temperature control and ensures comfort by
regulating underfloor heating, radiators and hydronic systems.
The thermostat helps reduce energy consumption while
keeping the temperature steady and comfortable.
The Heatit S-Control2 features an easy-to-use rotary wheel
for temperature regulation, making it simple to adjust settings.
The device includes a preinstalled temperature adjustment
wheel (5–40°C) and a 1–10 power regulator wheel in the box.
Additionally, it can be customized with various sensor options
to suit dierent needs. The thermostat has a user-friendly
design and is simple to install and program.
The thermostat fits in a standard European junction boxes and
may be used with most System 55 frames. It has a sturdy metal
frame for secure fastening in the junction box.
The thermostat has one built-in room temperature sensor.
Two additional external temperature sensors may also be
connected. The sensors can be used separately, or together to
prevent the floor from overheating. Heatit S-Control2 can also
be used as a power regulator.
The device is equipped with ZeroX™ technology, which
ensures the relay switches at 0V when turning on and o. This
technology significantly extends the thermostat’s lifespan.
NTC
NTC
INSTALLATION
Next, position the thermostat and mount it into the junction
box using 2 screws. Position the plastic front over the part
mounted in the junction box, then carefully press the front until
it clicks into place. Place the rotary wheel back on in the correct
position.
PRINCIPLES OF REGULATION
The thermostat uses temperature readings retrieved from the
internal sensor and/or from external wired sensors to regulate
the temperature. The thermostat will regulate the temperature
using hysteresis.
Hysteresis
Hysteresis sets the osets that are used with the setpoint to
determine when the load is switched on and o relative to the
measured temperature.
CHOICE OF SENSOR
The thermostat has multiple sensors and sensor modes. This
lets you configure the thermostat to work correctly in most
installations. The sensor mode is selected based on both the
DIP switch position, and the sensors connected.
AVAILABLE TEMPERATURE SENSORS
F Floor sensor
P Power regulator mode
(no sensor used)
A Internal room sensor
AF Internal sensor with
Floor sensor limitation
A2 External sensor
A2F External sensor with
floor sensor limitation
Quick Guide
Article no. Doc. version Doc. date
54 305 36
54 305 37
54 305 38
Ver-C 15.06.2025
PRODUCT
DOCUMENTS
HEATIT
S-CONTROL2
FEATURES
Rotary wheel
Digital ON/OFF button
Internal room sensor
External room sensor (wired by cable)
Floor sensor
Power regulator
Temperature limiter
ZeroX™ detection
Single poled switch
TECHNICAL DATA
Rated voltage 230VAC 50Hz
Max load 3600W 16A (resistive load)
Max current 16A
Power consumption <2W
Power regulator Time cycle 0 to 30 min.
Ambient temperature 5°C to 40°C
Regulation temperature C to 40°C
Storage temperature -3C to 70°C
Hysteresis 0.C
Humidity 10% to 85% RH
Compatible with NTC-
sensor with values 10k @ 2CΩ
Screw terminals Max. 2.5mm
2
2Nm
IP Code IP21
Size (LxWxH) 84 x 84 x 45.5mm
Approvals CE, Nemko
Hereby, Heatit Controls AS, declares that this device is in
compliance with the essential requirements another relevant
provisions of Directive 2014/53/EU.
MAINTENANCE
The product is maintenance-free.
Indoor use only.
Org. doc. 01.05.2024
Floor Sensor Requirement and Temperature Limiting
The temperature limits are minimum 5°C and maximum 40°C.
Some types of flooring require the use of a floor sensor to
ensure that the floor temperature does not exceed 27°C. Refer
to the floor manufacturer’s manual for specific guidelines.
When the thermostat operates in AF or A2F mode, the floor
temperature limiter is automatically set to 27°C.
In all other sensor modes (A, F or A2), the temperature limits are
set to minimum 5°C and maximum 40°C.
SAFETY FEATURES
The device has safety features to ensure safe operation and
warn the user of any faults/unexpected behavior. The device
has an Overheat and Overload function. If the thermostat
registers an Overheat or Overload incident, the thermostat will
switch o and the status LED will blink red.
Overheating
The device features internal temperature sensors to prevent
the device from overheating.
Overload
The device features overload protection. The overload is
triggered if there is a current draw of more than 16A.
THERMOSTAT SETPOINT
Regulation temperature from 5°C - 40°C.
THERMOSTAT DIMENSIONS
84mm
51mm
20.5 24.7mm 51mm
45.2mm
White RAL 9003
54 305 37
Black matt
54 305 38
White RAL 9010
54 305 36


Produktspecifikationer

Varumärke: Heatit
Kategori: Termostat
Modell: S-Control2